Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis

被引:107
|
作者
Wei, Shi-Min [1 ]
Zhu, Yu [1 ]
Wei, Jian-Xu [1 ]
Zhang, Chu-Nan [1 ]
Shi, Jun-Yu [1 ]
Lai, Hong-Chang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Key Lab Stomatol & Shanghai Res Inst Sto, Dept Oral & Maxillofacial Implantol,Natl Clin Res, Shanghai Ninth Peoples Hosp,Coll Stomatol,Sch Med, Shanghai, Peoples R China
关键词
computer‐ assisted surgery; dental implants; dynamic navigation; image‐ guided surgery; tooth implants;
D O I
10.1111/clr.13719
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To assess the accuracy of dynamic computer-assisted implant surgery. Materials and methods An electronic search up to March 2020 was conducted using PubMed, Embase, and the Cochrane Central Register of Controlled Trial to identify studies using dynamic navigation in implant surgery, and additional manual search was performed as well. Clinical trials and model studies were selected. The primary outcome was accuracy. A single-arm meta-analysis of continuous data was conducted. Meta-regression was utilized for comparison on study design, guidance method, jaw, and systems. Results Ten studies, four randomized controlled trials (RCT) and six prospective studies, met the inclusion criteria. A total of 1,298 drillings and implants were evaluated. The meta-analysis of the accuracy (five clinical trials and five model studies) revealed average global platform deviation, global apex deviation, and angular deviation were 1.02 mm, 95% CI (0.83, 1.21), 1.33 mm, 95% CI (0.98, 1.67), and 3.59 degrees, 95% CI (2.09, 5.09). Meta-regression shown no difference between model studies and clinical trials (p = .295, 0.336, 0.185), drilling holes and implant (p = .36, 0.279, 0.695), maxilla and mandible (p = .875, 0.632, 0.281), and five different systems (p = .762, 0.342, 0.336). Conclusion Accuracy of dynamic computer-aided implant surgery reaches a clinically acceptable range and has potential in clinical usage, but more patient-centered outcomes and socio-economic benefits should be reported.
引用
收藏
页码:383 / 393
页数:11
相关论文
共 50 条
  • [21] Systematic Review and Meta-Analysis on Incidence of Altered Sensation of Mandibular Implant Surgery
    Lin, Chia-Shu
    Wu, Shih-Yun
    Huang, Hsin-Yi
    Lai, Yu-Lin
    PLOS ONE, 2016, 11 (04):
  • [22] Immediate implant placement with flap or flapless surgery: A systematic review and meta-analysis
    Pitman, Jeremy
    Christiaens, Veronique
    Callens, Jeroen
    Glibert, Maarten
    Seyssens, Lorenz
    Blanco, Juan
    Cosyn, Jan
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2023, : 755 - 764
  • [23] Guided and Navigation Implant Surgery: A Systematic Review
    Aghaloo, Tara
    Hadaya, Danny
    Schoenbaum, Todd R.
    Pratt, Lauren
    Favagehi, Mehrdad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 : 7 - 15b
  • [24] Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies
    Jain, Saurabh
    Sayed, Mohammed E.
    Ibraheem, Wael I.
    Ageeli, Abrar A.
    Gandhi, Sumir
    Jokhadar, Hossam F.
    Alresayes, Saad Saleh
    Alqarni, Hatem
    Alshehri, Abdullah Hasan
    Huthan, Halah Mohammed
    Alami, Atheer
    Al Wadei, Mohammed Hussain Dafer
    Aljabri, Yahya
    MEDICINA-LITHUANIA, 2024, 60 (01):
  • [25] Bone graft substitutes and dental implant stability in immediate implant surgery: a systematic review and meta-analysis
    Vanka, Shanthi
    Abul Kasem, Fatima
    Kailani, Tasnem
    Wali, Othman
    Vanka, Amit
    EVIDENCE-BASED DENTISTRY, 2024, : 70 - 70
  • [26] AHMED IMPLANT VERSUS BAERVELDT IMPLANT: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Fau, C.
    Nabzo, S.
    VALUE IN HEALTH, 2015, 18 (07) : A880 - A880
  • [27] Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies
    Bover-Ramos, Fernando
    Vina-Almunia, Jose
    Cervera-Ballester, Juan
    Penarrocha-Diago, Miguel
    Garcia-Mira, Berta
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 101 - 115
  • [28] Accuracy of Machine Learning in Identification of Dental Implant Systems in Radiographs - A Systematic Review and Meta-analysis
    Benakatti, Veena
    Nayakar, Ramesh P.
    Anandhalli, Mallikarjun
    Lagali-Jirge, Vasanti
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (03) : 354 - 358
  • [29] Comparison of accuracy in freehand versus computer-assisted (dynamic and static) dental implant placement: A systematic review and meta-analysis
    Banerjee, Saurav
    Debnath, Anasua
    Paul, Priyanjali
    Banerjee, Tridib Nath
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01): : 22 - 29
  • [30] Bariatric surgery: A systematic review and meta-analysis
    Buchwald, H
    Avidor, Y
    Braunwald, E
    Jensen, MD
    Pories, W
    Fahrbach, K
    Schoelles, K
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (14): : 1724 - 1737