The thin-foil magnetic proton recoil neutron spectrometer MPRu at JET

被引:45
|
作者
Sunden, E. Andersson [1 ]
Sjoestrand, H. [1 ]
Conroy, S. [1 ]
Ericsson, G. [1 ]
Johnson, M. Gatu [1 ]
Giacomelli, L. [1 ]
Hellesen, C. [1 ]
Hjalmarsson, A. [1 ]
Ronchi, E. [1 ]
Weiszflog, M. [1 ]
Kaellne, J. [2 ]
Gorini, G. [3 ,4 ]
Tardocchi, M. [3 ,4 ]
Combo, A. [5 ]
Cruz, N. [5 ]
Batista, A. [5 ]
Pereira, R. [5 ]
Fortuna, R. [5 ]
Sousa, J. [5 ]
Popovichev, S. [6 ]
机构
[1] Uppsala Univ, Dept Phys & Astron, EURATOM VR, S-75120 Uppsala, Sweden
[2] Uppsala Univ, Dept Engn Sci, EURATOM VR, S-75121 Uppsala, Sweden
[3] Milano Bicocca Univ, Dept Phys, Milan, Italy
[4] EURATOM ENEA CNR, CNR, Ist Fis Plasma, Milan, Italy
[5] EURATOM IST, Inst Super Tecn, Ctr Fusao Nucl, P-1049001 Lisbon, Portugal
[6] Culham Sci Ctr, JET EFDA, Abingdon OX14 3DB, Oxon, England
基金
瑞典研究理事会;
关键词
Neutron; Spectrometer; 14 MeV neutrons; 2.5 MeV neutrons; MPR; MPRu; Fusion; Diagnostic; HIGH-PERFORMANCE; EMISSION; CALIBRATION; SYSTEM;
D O I
10.1016/j.nima.2009.09.025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutrons are produced in fusion energy experiments with both deuterium (D) and deuterium-tritium (DT) plasmas. Neutron spectroscopy is a valuable tool in the study of the underlying fuel ion populations. The magnetic proton recoil neutron spectrometer, originally installed at JET in 1996 for 14-MeV neutron measurements, has been upgraded, with the main aim of improving its signal-to-background ratio (S/B), making measurements of the 2.5-MeV neutron emission in D plasmas possible. The upgrade includes a new focal-plane detector, based on the phoswich technique and consequently less sensitive to background, and a new custom-designed digital data acquisition system based on transient recorder cards. Results from JET show that the upgraded MPRu can measure 2.5-MeV neutrons with S/B=5, an improvement by a factor of 50 compared with the original MPR.S/B of 2.8 x 10(4) in future DT experiments is estimated. The performance of the MPRu is exemplified with results from recent D plasma operations at JET, concerning both measurements with Ohmic, ion cyclotron resonance (ICRH) and neutral beam injection (NBI) plasma heating, as well as measurements of tritium burn-up neutrons. The upgraded instrument allows for 2.5-MeV neutron emission and deuterium ion temperature measurements in plasmas with low levels of tritium, a feature necessary for the ITER experiment. (C) 2009 Euratom. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:682 / 699
页数:18
相关论文
共 50 条
  • [41] High energy proton beam from a laser irradiated thin-foil target and its possible applications
    Nishiuichi, M
    Fukumi, A
    Daido, H
    Li, Z
    Sagisaka, A
    Ogura, K
    Orimo, S
    Kado, M
    Hayashi, Y
    Mori, M
    Bulanov, SV
    Esirkepov, T
    Nemoto, K
    Oishi, Y
    Nayuki, T
    Noda, A
    Nakamura, S
    LASER PHYSICS LETTERS, 2006, 3 (03) : 162 - 167
  • [42] Simultaneous generation of a proton beam and terahertz radiation in high-intensity laser and thin-foil interaction
    A. Sagisaka
    H. Daido
    S. Nashima
    S. Orimo
    K. Ogura
    M. Mori
    A. Yogo
    J. Ma
    I. Daito
    A.S. Pirozhkov
    S.V. Bulanov
    T.Zh. Esirkepov
    K. Shimizu
    M. Hosoda
    Applied Physics B, 2008, 90 : 373 - 377
  • [43] Simultaneous generation of a proton beam and terahertz radiation in high-intensity laser and thin-foil interaction
    Sagisaka, A.
    Daido, H.
    Nashima, S.
    Orimo, S.
    Ogura, K.
    Mori, M.
    Yogo, A.
    Ma, J.
    Daito, I.
    Pirozhkov, A. S.
    Bulanov, S. V.
    Esirkepov, T. Zh.
    Shimizu, K.
    Hosoda, M.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (3-4): : 373 - 377
  • [44] Thin YAP:Ce and LaBr3:Ce scintillators as proton detectors of a thin-film proton recoil neutron spectrometer for fusion and spallation sources applications
    Cazzaniga, C.
    Nocente, M.
    Tardocchi, M.
    Fazzi, A.
    Hjalmarsson, A.
    Rigamonti, D.
    Ericsson, G.
    Gorini, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 751 : 19 - 22
  • [45] Accurate determination of neutron spectra in space with a special proton-recoil scintillation spectrometer
    Koslowsky, VT
    Noulty, RA
    Ing, H
    Peterson, D
    PROCEEDINGS OF THE 11TH CONFERENCE ON ASTRONAUTICS: OPPORTUNITIES AND CHALLENGES FOR SPACE APPLICATIONS AND TECHNOLOGY, 2000, : 251 - 256
  • [46] The magnetic recoil spectrometer (MRS) for absolute measurements of the neutron spectrum at OMEGA and the NIF
    Frenje, Johan A.
    Casey, Daniel T.
    Seguin, Fredrick H.
    Li, Chikang
    Petrasso, Richard D.
    Glebov, Vladimir Yu
    Sangster, Thomas C.
    Meyerhofer, David D.
    Hatchett, Steve
    Haan, Steve
    Cerjan, Charles
    Landen, Otto
    Moran, Michael
    Fletcher, Kurt T.
    Leeper, Raymon J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [47] Design and performance analysis of a compact magnetic proton recoil spectrometer for DT neutrons
    祁建敏
    周林
    蒋世伦
    中国物理C, 2011, 35 (04) : 374 - 380
  • [48] Design and performance analysis of a compact magnetic proton recoil spectrometer for DT neutrons
    Qi Jian-Min
    Zhou Lin
    Jiang Shi-Lun
    CHINESE PHYSICS C, 2011, 35 (04) : 374 - 380
  • [49] THIN-FOIL TRANSMISSION ELECTRON-MICROSCOPIC STUDY OF NEUTRON-IRRADIATED A212B STEEL
    BIRKLE, AJ
    RALL, W
    TRANSACTIONS OF THE METALLURGICAL SOCIETY OF AIME, 1964, 230 (01): : 156 - &
  • [50] DETERMINATION OF D(3)-BE AND D(4)-BE NEUTRON-SPECTRA USING A RECOIL PROTON SPECTROMETER
    FOLKARD, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (02): : 135 - 144