The thin-foil magnetic proton recoil neutron spectrometer MPRu at JET

被引:45
|
作者
Sunden, E. Andersson [1 ]
Sjoestrand, H. [1 ]
Conroy, S. [1 ]
Ericsson, G. [1 ]
Johnson, M. Gatu [1 ]
Giacomelli, L. [1 ]
Hellesen, C. [1 ]
Hjalmarsson, A. [1 ]
Ronchi, E. [1 ]
Weiszflog, M. [1 ]
Kaellne, J. [2 ]
Gorini, G. [3 ,4 ]
Tardocchi, M. [3 ,4 ]
Combo, A. [5 ]
Cruz, N. [5 ]
Batista, A. [5 ]
Pereira, R. [5 ]
Fortuna, R. [5 ]
Sousa, J. [5 ]
Popovichev, S. [6 ]
机构
[1] Uppsala Univ, Dept Phys & Astron, EURATOM VR, S-75120 Uppsala, Sweden
[2] Uppsala Univ, Dept Engn Sci, EURATOM VR, S-75121 Uppsala, Sweden
[3] Milano Bicocca Univ, Dept Phys, Milan, Italy
[4] EURATOM ENEA CNR, CNR, Ist Fis Plasma, Milan, Italy
[5] EURATOM IST, Inst Super Tecn, Ctr Fusao Nucl, P-1049001 Lisbon, Portugal
[6] Culham Sci Ctr, JET EFDA, Abingdon OX14 3DB, Oxon, England
基金
瑞典研究理事会;
关键词
Neutron; Spectrometer; 14 MeV neutrons; 2.5 MeV neutrons; MPR; MPRu; Fusion; Diagnostic; HIGH-PERFORMANCE; EMISSION; CALIBRATION; SYSTEM;
D O I
10.1016/j.nima.2009.09.025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutrons are produced in fusion energy experiments with both deuterium (D) and deuterium-tritium (DT) plasmas. Neutron spectroscopy is a valuable tool in the study of the underlying fuel ion populations. The magnetic proton recoil neutron spectrometer, originally installed at JET in 1996 for 14-MeV neutron measurements, has been upgraded, with the main aim of improving its signal-to-background ratio (S/B), making measurements of the 2.5-MeV neutron emission in D plasmas possible. The upgrade includes a new focal-plane detector, based on the phoswich technique and consequently less sensitive to background, and a new custom-designed digital data acquisition system based on transient recorder cards. Results from JET show that the upgraded MPRu can measure 2.5-MeV neutrons with S/B=5, an improvement by a factor of 50 compared with the original MPR.S/B of 2.8 x 10(4) in future DT experiments is estimated. The performance of the MPRu is exemplified with results from recent D plasma operations at JET, concerning both measurements with Ohmic, ion cyclotron resonance (ICRH) and neutral beam injection (NBI) plasma heating, as well as measurements of tritium burn-up neutrons. The upgraded instrument allows for 2.5-MeV neutron emission and deuterium ion temperature measurements in plasmas with low levels of tritium, a feature necessary for the ITER experiment. (C) 2009 Euratom. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:682 / 699
页数:18
相关论文
共 50 条
  • [1] Proposed Magnetic Proton Recoil neutron spectrometer upgrade (MPRu)
    Ericsson, G
    Conroy, S
    Gorini, G
    Henriksson, H
    Hjalmarsson, A
    Källne, J
    Tardocchi, M
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 121 - 124
  • [2] Development and characterization of the proton recoil detector for the MPRu neutron spectrometer
    Giacomelli, L.
    Sunden, E. Andersson
    Conroy, S.
    Ericsson, G.
    Johnson, M. Gatu
    Hellesen, C.
    Hjalmarsson, A.
    Kallne, J.
    Ronchi, E.
    Sjostrand, H.
    Weiszflog, M.
    Gorini, G.
    Tardocchi, M.
    Murari, A.
    Popovichev, S.
    Sousa, J.
    Pereira, R. C.
    Combo, A.
    Cruz, N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [3] A Thin-foil Proton Recoil spectrometer for DT neutrons using annular silicon detectors
    Marcinkevicius, B.
    Sunden, E. Andersson
    Conroy, S.
    Ericsson, G.
    Hjalmarsson, A.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (03)
  • [4] A PCI transient recorder module for the JET magnetic proton recoil neutron spectrometer
    Combo, A
    Pereira, R
    Sousa, J
    Cruz, N
    Carvalho, P
    Varandas, CAF
    Conroy, S
    Källne, J
    Weiszflog, M
    FUSION ENGINEERING AND DESIGN, 2004, 71 (1-4) : 151 - 157
  • [5] Gain stabilization control system of the upgraded magnetic proton recoil neutron spectrometer at JET
    Sjostrand, Henrik
    Sunden, E. Andersson
    Conroy, S.
    Ericsson, G.
    Johnson, M. Gatu
    Giacomelli, L.
    Gorini, G.
    Hellesen, C.
    Hjalmarsson, A.
    Popovichev, S.
    Ronchi, E.
    Tardocchi, M.
    Weiszflog, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (06):
  • [6] Neutron emission spectroscopy at JET -: Results from the magnetic proton recoil spectrometer (invited)
    Ericsson, G
    Ballabio, L
    Conroy, S
    Frenje, J
    Henriksson, H
    Hjalmarsson, A
    Källne, J
    Tardocchi, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 759 - 766
  • [7] Magnetic proton recoil spectrometer for neutron spectrum measurements
    Chen, J. (jbchen1978@163.com), 1600, Editorial Office of High Power Laser and Particle Beams, P.O. Box 919-805, Mianyang, 621900, China (24):
  • [8] New neutron diagnostics with the magnetic proton recoil spectrometer
    Källne, J
    Ballabio, L
    Conroy, S
    Ericsson, G
    Frenje, J
    Gorini, G
    Prandoni, P
    Tardocchi, M
    Traneus, E
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 1181 - 1184
  • [9] Calibration of a compact magnetic proton recoil neutron spectrometer
    Zhang, Jianfu
    Ouyang, Xiaoping
    Zhang, Xianpeng
    Ruan, Jinlu
    Zhang, Guoguang
    Zhang, Xiaodong
    Qiu, Suizheng
    Chen, Liang
    Liu, Jinliang
    Song, Jiwen
    Liu, Linyue
    Yang, Shaohua
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 816 : 125 - 130
  • [10] A Thin-foil Proton Recoil spectrometer for DT neutrons using annular silicon detectors (vol 14, P03007, 2019)
    Marcinkevicius, B.
    Sunden, E. Andersson
    Conroy, S.
    Ericsson, G.
    Hjalmarsson, A.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (01):