A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode

被引:96
|
作者
Jia, Ningming [1 ]
Huang, Baozhen [1 ]
Chen, Lina [1 ]
Tan, Liang [1 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Normal Univ, Key Lab Chem Biol & Tradit Chinese Med Res, Minist Educ China, Coll Chem & Chem Engn, Changsha 410081, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; Graphene; Chitosan; Chemically modified electrode; Hydrogen peroxide; Direct electrochemistry; CARBON NANOTUBES; SUPEROXIDE; REDUCTION; STATE; OXIDE; H2O2;
D O I
10.1016/j.snb.2014.01.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold nanoparticles (GNPs) were electrochemically deposited on the graphene and chitosan modified glassy carbon electrode and characterized by scanning electron microscope and cyclic voltammetry, respectively. A simple non-enzymatic H2O2 sensor was developed based on the direct electrochemistry of H2O2 in the presence of GNPs. Under the optimized conditions, the fabricated electrode displayed a linear response in the H2O2 concentration range from 5.0 mu M to 35 mM with a detection limit of 1.6 mu M estimated at a signal-to-noise ratio of 3. The proposed sensor presented some advantages including simple operation procedure, wide linear range, low detection limit, fast response time as well as good anti-interference performance, stability and reproducibility, which indicate it can act as a promising electrochemical platform for H2O2 detection. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [21] Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate) - Carboxylated Graphene Modified Graphite Electrode
    Prasannakumar, S.
    Manjunatha, R.
    Nethravathi, C.
    Suresh, G. S.
    Rajamathi, M.
    Venkatesha, T. V.
    [J]. PORTUGALIAE ELECTROCHIMICA ACTA, 2012, 30 (06) : 371 - 383
  • [22] Non-enzymatic detection of hydrogen peroxide using a functionalized three-dimensional graphene electrode
    Xi, Fengna
    Zhao, Dongjiao
    Wang, Xuewan
    Chen, Peng
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2013, 26 : 81 - 84
  • [23] A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode
    Song, Min-Jung
    [J]. KOREAN CHEMICAL ENGINEERING RESEARCH, 2023, 61 (02): : 196 - 201
  • [24] Non-enzymatic oxalic acid sensor using platinum nanoparticles modified on graphene nanosheets
    Chen, Xiaomei
    Cai, Zhixiong
    Huang, Zhiyong
    Oyama, Munetaka
    Jiang, Yaqi
    Chen, Xi
    [J]. NANOSCALE, 2013, 5 (13) : 5779 - 5783
  • [25] Non-enzymatic amperometric sensor for hydrogen peroxide based on a biocomposite made from chitosan, hemoglobin, and silver nanoparticles
    Li Tian
    Yongjia Feng
    Yanjuan Qi
    Binbin Wang
    Yinran Chen
    Xueyan Fu
    [J]. Microchimica Acta, 2012, 177 : 39 - 45
  • [26] Non-enzymatic electrochemical sensing of glucose and hydrogen peroxide using a bis(acetylacetonato) oxovanadium(IV) complex modified gold electrode
    Barman, Koushik
    Jasimuddin, Sk
    [J]. RSC ADVANCES, 2016, 6 (25) : 20800 - 20806
  • [27] Non-enzymatic amperometric sensor for hydrogen peroxide based on a biocomposite made from chitosan, hemoglobin, and silver nanoparticles
    Tian, Li
    Feng, Yongjia
    Qi, Yanjuan
    Wang, Binbin
    Chen, Yinran
    Fu, Xueyan
    [J]. MICROCHIMICA ACTA, 2012, 177 (1-2) : 39 - 45
  • [28] A novel hydrogen peroxide sensor based on Ag nanoparticles electrodeposited on chitosan-graphene oxide/cysteamine-modified gold electrode
    Wang, Li
    Zhu, Haozhi
    Hou, Haoqing
    Zhang, Zhiyao
    Xiao, Xianping
    Song, Yonghai
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1693 - 1700
  • [29] A novel hydrogen peroxide sensor based on Ag nanoparticles electrodeposited on chitosan-graphene oxide/cysteamine-modified gold electrode
    Li Wang
    Haozhi Zhu
    Haoqing Hou
    Zhiyao Zhang
    Xianping Xiao
    Yonghai Song
    [J]. Journal of Solid State Electrochemistry, 2012, 16 : 1693 - 1700
  • [30] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395