The influence of nasal abnormalities in adherence to continuous positive airway pressure device therapy in obstructive sleep apnea patients

被引:8
|
作者
Martinho Haddad, Fernanda Louise [1 ,2 ]
Vidigal, Tatiana de Aguiar [2 ]
Mello-Fujita, Luciane [1 ]
Cintra, Fatima Dumas [1 ]
Gregorio, Luiz Carlos [2 ]
Tufik, Sergio [1 ]
Bittencourt, Lia [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Psicobiol, Disciplina Med & Biol Sono, BR-04024002 Sao Paulo, Brazil
[2] Univ Fed Sao Paulo, Dept Otorrinolaringol & Cirurgia Cabeca & Pescoco, BR-04024002 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Acoustic rhinometry; Nasofibroscopy; Nasal inspiratory peak flow; Nasal obstruction; Obstructive sleep apnea; Upper airway; RESISTANCE; SURGERY;
D O I
10.1007/s11325-013-0824-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The few studies that examine the effect of nasal abnormalities on continuous positive airway pressure device (CPAP) adherence are controversial. The aim of this study was to evaluate the contribution of nasal abnormalities in CPAP adherence. We included patients with moderate to severe OSA. The patients were submitted to rhinoscopy, nasofibroscopy, nasal inspiratory peak flow, and acoustic rhinometry. The patients who used a CPAP for 4 h or more per night for at least 70 % of the nights over a 6-month period were considered to have good adherence. Thirty-four patients finished the study. Eleven (33.4 %) were female and 23 (67.6 %) were male. Sixteen (47.1 %) patients had good adherence. The body mass index (p = 0.030), neck circumference (p = 0.006), and apnea-hypopnea index (p = 0.032) were higher, and the oxyhemoglobin saturation minimum was lower (p = 0.041) in the good adherence group. Nasal parameters showed no differences between good and poor adherence groups. In Spearman's correlation, surprisingly, there was a negative correlation between the highest number of hours of CPAP use with smaller values of nasal minimal cross-sectional areas in the supine position (r, 0.375; p = 0.029). In the linear regression model, the nasal findings that predicted increased of the CPAP use were the following: lower scores of nasal symptoms (p = 0.007) and lower nasal volume in supine position (p = 0.001). The majority of the nasal parameters evaluated in this study did not influence CPAP adherence.
引用
收藏
页码:1201 / 1207
页数:7
相关论文
共 50 条
  • [1] The influence of nasal abnormalities in adherence to continuous positive airway pressure device therapy in obstructive sleep apnea patients
    Fernanda Louise Martinho Haddad
    Tatiana de Aguiar Vidigal
    Luciane Mello-Fujita
    Fátima Dumas Cintra
    Luiz Carlos Gregório
    Sérgio Tufik
    Lia Bittencourt
    Sleep and Breathing, 2013, 17 : 1201 - 1207
  • [2] THE INFLUENCE OF NASAL ALTERATIONS IN ADHERENCE TO THE CONTINUOUS POSITIVE AIRWAY PRESSURE IN OBSTRUCTIVE SLEEP APNEA PATIENTS
    Bittencourt, L. A.
    Haddad, F. M.
    Mello-Fujita, L.
    Cintra, F.
    Poyares, D.
    Gregorio, L.
    Tufik, S.
    SLEEP, 2011, 34 : A118 - A118
  • [3] The influence of nasal abnormalities in adherence to continuous positive airway pressure device therapy in obstructive sleep apnea patients. What role does the nose play?
    Cambi, Jacopo
    Politi, Leandro
    Passali, Francesco Maria
    Passali, Desiderio
    SLEEP AND BREATHING, 2014, 18 (04) : 677 - 678
  • [4] The influence of nasal abnormalities in adherence to continuous positive airway pressure device therapy in obstructive sleep apnea patients. What role does the nose play?
    Jacopo Cambi
    Leandro Politi
    Francesco Maria Passali
    Desiderio Passali
    Sleep and Breathing, 2014, 18 : 677 - 678
  • [5] The influence of nasal abnormalities in adherence to continuous positive airway pressure device therapy in obstructive sleep apnea patients. What role does the nose play?
    Fernanda Louise Martinho Haddad
    Tatiana Vidigal
    Luciane Mello-Fujita
    Fátima Dumas Cintra
    Luiz Carlos Gregório
    Sergio Tufik
    Lia Rita Azeredo Bittencourt
    Sleep and Breathing, 2015, 19 : 5 - 6
  • [6] The influence of nasal abnormalities in adherence to continuous positive airway pressure device therapy in obstructive sleep apnea patients. What role does the nose play?
    Martinho Haddad, Fernanda Louise
    Vidigal, Tatiana
    Mello-Fujita, Luciane
    Cintra, Fatima Dumas
    Gregorio, Luiz Carlos
    Tufik, Sergio
    Azeredo Bittencourt, Lia Rita
    SLEEP AND BREATHING, 2015, 19 (01) : 5 - 6
  • [7] Adherence to Continuous Positive Airway Pressure therapy in Singaporean patients with Obstructive Sleep Apnea
    Tan Wen Sheng, Bernard
    Tan Kah Leong, Alvin
    Huak, Chan Yiong
    Yingjuan, Mok
    Siang, Wong Hang
    Poh, Hsu Pon
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2018, 39 (05) : 501 - 506
  • [8] The influence of obstructive sleep apnea and continuous positive airway pressure on the nasal microbiome
    Lenk, C.
    Messbacher, M. E.
    Abel, J.
    Mueller, S. K.
    Mantsopoulos, K.
    Gostian, A. O.
    Sievert, M.
    Wirtz, S.
    Marxreiter, F.
    Winkler, J.
    Iro, H.
    Traxdorf, M.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (06) : 2605 - 2618
  • [9] Determinants for adherence to continuous positive airway pressure therapy in obstructive sleep apnea
    Jacobsen, Anne Roed
    Eriksen, Freja
    Hansen, Rasmus Wurgler
    Erlandsen, Mogens
    Thorup, Line
    Damgard, Mette Bjerre
    Kirkegaard, Martin Glumer
    Hansen, Klavs Wurgler
    PLOS ONE, 2017, 12 (12):
  • [10] Factors influencing adherence to nasal continuous positive airway pressure in obstructive sleep apnea patients in Japan
    Uematsu, Akihito
    Akashiba, Tsuneto
    Kumasawa, Fumio
    Akahoshi, Toshiki
    Okamoto, Naoki
    Nagaoka, Kenichi
    Gon, Yasuhiro
    Kaneita, Yoshitaka
    Uchiyama, Makoto
    Hashimoto, Shu