Adjustable artificial chordal replacement for repair of mitral valve prolapse

被引:41
|
作者
Rankin, JS
Orozco, RE
Rodgers, TL
Alfery, DD
Glower, DD
机构
[1] Vanderbilt Univ, Centennial Hosp, Nashville, TN USA
[2] Duke Univ, Med Ctr, Durham, NC USA
来源
ANNALS OF THORACIC SURGERY | 2006年 / 81卷 / 04期
关键词
D O I
10.1016/j.athoracsur.2005.01.042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Achieving a stable repair of mitral valve prolapse can be difficult in complex pathologies, and a 5% to 20% late reoperation rate exists with leaflet resection and reconstruction. During an 8-year period, prolapse was managed uniformly with "adjustable" Gortex (W. L. Gore & Associates Inc, Flagstaff, AZ) artificial chordal replacement and Carpentier ring annuloplasty ( Edwards Life-sciences LLC, Irvine, CA), without leaflet resection. Artificial chords were placed initially in the papillary muscles, and then after ring annuloplasty they were adjusted to optimize length to the prolapsing segment(s). Of 52 patients with prolapse, 100% were repaired successfully with artificial chords. Operative mortality was 1.9%, and 4, 6, and 8-year survivals were 87%, 81%, and 71%, respectively. Only 1 of 52 patients ( 1.9%) experienced late failure, and this patient was re-repaired with artificial chords. Thus, "adjustable" artificial chordal replacement facilitates uniform repair of mitral valve prolapse with a low late failure rate.
引用
收藏
页码:1526 / 1528
页数:3
相关论文
共 50 条
  • [31] A novel technique of utilizing artificial chordae for repair of mitral valve prolapse
    Scorsin, Marcio
    Al-Attar, Nawwar
    Lessana, Arrigo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (04): : 1072 - 1073
  • [32] Simplified chordal reconstruction: 'oblique' placement of artificial chordae tendineae in mitral valve replacement
    Soga, Y
    Nishimura, K
    Yamazaki, K
    Komeda, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (04) : 653 - 655
  • [33] Mitral-Valve Repair for Mitral-Valve Prolapse
    Verma, Subodh
    Mesana, Thierry G.
    NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23): : 2261 - 2269
  • [34] ABNORMAL CHORDAL INSERTION - A CAUSE OF MITRAL-VALVE PROLAPSE
    VIRMANI, R
    ATKINSON, JB
    BYRD, BF
    ROBINOWITZ, M
    FORMAN, MB
    AMERICAN HEART JOURNAL, 1987, 113 (04) : 851 - 858
  • [35] ABNORMAL CHORDAL INSERTION - A CAUSE OF MITRAL-VALVE PROLAPSE
    ATKINSON, JB
    FORMAN, MB
    BYRD, BF
    ROBINOWITZ, M
    VIRMANI, R
    CIRCULATION, 1985, 72 (04) : 42 - 42
  • [36] ABNORMAL CHORDAL INSERTION - A CAUSE OF MITRAL-VALVE PROLAPSE
    ATKINSON, JB
    FORMAN, MB
    BYRD, BF
    ROBINOWITZ, M
    VIRMANI, R
    LABORATORY INVESTIGATION, 1986, 54 (01) : A4 - A4
  • [37] Intracardiac Calipers for Artificial Chordae Replacement in Mitral Valve Repair
    Doi, Atsuo
    Iida, Hiroshi
    Sunazawa, Toru
    ANNALS OF THORACIC SURGERY, 2009, 87 (01): : 326 - 328
  • [38] Mitral Valve Replacement After Failed Mitral Ring Insertion With or Without Leaflet/Chordal Repair for Pure Mitral Regurgitation
    Roberts, William C.
    Moore, Meagan
    Ko, Jong Mi
    Hamman, Baron L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (11): : 1790 - 1807
  • [39] Mitral valve replacement with chordal preservation in a rheumatic population
    Wasir, H
    Choudhary, SK
    Airan, B
    Srivastava, S
    Kumar, AS
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (01): : 84 - 89
  • [40] Beating-heart Mitral Valve Chordal Replacement
    Laing, Genevieve
    Dupont, Pierre E.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2476 - 2479