End-tidal sevoflurane concentration for tracheal extubation (MACEX) in adults:: comparison with isoflurane

被引:20
|
作者
Inomata, S [1 ]
Yaguchi, Y [1 ]
Taguchi, M [1 ]
Toyooka, H [1 ]
机构
[1] Univ Tsukuba, Dept Anaesthesiol, Inst Clin Med, Ibaraki, Osaka 305, Japan
关键词
anaesthetics volatile; sevoflurane; isoflurane; potency; anaesthetic; MAC; intubation tracheal; extubation;
D O I
10.1093/bja/82.6.852
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Sevoflurane has a non-pungent odour and provides smooth induction of anaesthesia, In contrast, isoflurane is irritating to the airway when used for induction, and this may also be evident during emergence from anaesthesia. We measured the end-tidal concentration of anaesthetic that prevented response to extubation in 50% of patients (MAC(EX)) in adults receiving either sevoflurane or isoflurane, Airway complications during emergence from anaesthesia were also noted. We studied 51 adult patients, ASA I, aged 36-59 yr. Patients received sevoflurane (n = 29) or isoflurane (n = 22) for elective intraocular surgery. The concentration at which extubation was attempted was determined by a modification of Dixon's up-and-down method. When tracheal extubation was accomplished without coughing and gross purposeful muscular movements within min after extubation, it was considered a smooth tracheal extubation. Patients who developed breath-holding or laryngospasm immediately after tracheal extubation were regarded as not having been extubated smoothly. In addition, patients were observed for respiratory events during the remainder of the emergence period. MAC(EX) values for sevoflurane and isoflurane were 1.07% and 0.83%, respectively. ED95 Values of sevoflurane and isoflurane were 2.04% and 1.19%, respectively, In 12 patients in the isoflurane group, extubation was smooth but six patients had coughing episodes during the remainder of the emergence period. In contrast, one of 15 patients in the sevoflurane group in whom tracheal extubation was smooth coughed later (P = 0.035). Airway obstruction was frequent when tracheal extubation was performed at end-tidal concentrations exceeding I MAC(EX) for each anaesthetic.
引用
收藏
页码:852 / 856
页数:5
相关论文
共 50 条
  • [21] Correlation of bispectral index with end-tidal sevoflurane concentration and age in infants and children
    Kim, HS
    Oh, AY
    Kim, CS
    Kim, SD
    Seo, KS
    Kim, JH
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (03) : 362 - 366
  • [22] The quotient end-tidal/inspired concentration of sevoflurane in a low-flow system
    Johansson, A
    Lundberg, D
    Luttropp, HH
    JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (04) : 267 - 270
  • [23] Minimum alveolar concentration of sevoflurane for tracheal extubation in children
    Higuchi, H
    Ura, T
    Taoda, M
    Tanaka, K
    Satoh, T
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 (07) : 911 - 913
  • [24] The effect of fentanyl on the end-tidal sevoflurane concentration needed to prevent motor movement in dogs
    Reilly, Sabrina
    Seddighi, Reza
    Egger, Christine M.
    Rohrbach, Barton W.
    Doherty, Thomas J.
    Qu, Wen
    Johnson, James R.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (03) : 290 - 296
  • [25] Effects of ventilation and isoflurane end-tidal concentration on intracranial and cerebral perfusion pressures in horses
    Brosnan, RJ
    Steffey, EP
    LeCouteur, RA
    Imai, A
    Farver, TB
    Kortz, GD
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2003, 64 (01) : 21 - 25
  • [26] Effect of fentanyl and lidocaine on the end-tidal sevoflurane concentration preventing motor movement in dogs
    Suarez, Martin A.
    Seddighi, Reza
    Egger, Christine M.
    Rohrbach, Barton W.
    Cox, Sherry K.
    KuKanich, Butch K.
    Doherty, Thomas J.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2017, 78 (01) : 12 - 16
  • [27] Comparison of the arterial blood gas, arterial oxyhaemoglobin saturation and end-tidal carbon dioxide tension during sevoflurane or isoflurane anaesthesia in rabbits
    Ayse Topal
    Nihal Gül
    Irish Veterinary Journal, 59
  • [28] Comparison of the arterial blood gas, arterial oxyhaemoglobin saturation and end-tidal carbon dioxide tension during sevoflurane or isoflurane anaesthesia in rabbits
    Topal, A
    Gül, N
    IRISH VETERINARY JOURNAL, 2006, 59 (05) : 278 - 281
  • [29] The dynamic relationship between end-tidal sevoflurane and isoflurane concentrations and bispectral index and spectral edge frequency of the electroencephalogram
    Olofsen, E
    Dahan, A
    ANESTHESIOLOGY, 1999, 90 (05) : 1345 - 1353
  • [30] QUANTITATIVE ELECTROENCEPHALOGRAPHY IN DOGS ANESTHETIZED WITH 2.0-PERCENT END-TIDAL CONCENTRATION OF ISOFLURANE ANESTHESIA
    MOORE, MP
    GREENE, SA
    KEEGAN, RD
    GALLAGHER, L
    GAVIN, PR
    KRAFT, SL
    DEHAAN, C
    KLAPPENBACH, K
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1991, 52 (04) : 551 - 560