Design and Benchtop Validation of a Handheld Integrated Dynamic Breast Imaging System for Noninvasive Characterization of Suspicious Breast Lesions

被引:9
|
作者
Xu, Ronald X. [1 ,3 ]
Ewing, Joseph [2 ]
El-Dahdah, Hamid [1 ]
Wang, Bei [3 ]
Povoski, Stephen P. [4 ,5 ,6 ]
机构
[1] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Elect & Comp Engn, Columbus, OH 43210 USA
[4] Ohio State Univ, Div Surg Oncol, Arthur G James Canc Hosp, Columbus, OH 43210 USA
[5] Ohio State Univ, Richard J Solove Res Inst, Columbus, OH 43210 USA
[6] Ohio State Univ, Ctr Comprehens Canc, Columbus, OH 43210 USA
关键词
Near infrared imaging and spectroscopy; Ultrasound; Breast cancer; Dynamic stimulation;
D O I
10.1177/153303460800700609
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We have developed a portable, handheld, integrated, dynamic breast imaging system that integrates a near infrared tissue oximeter, clinical ultrasound, and two pressure sensors for noninvasive detection of pressure-induced structural and functional dynamics of Suspicious breast lesions. A series of benchtop tests were conducted to validate multiple performance characteristics of the integrated dynamic near infrared/ultrasound breast imaging system (idNIRUS), including the reconstruction of the absorptive heterogeneities and the generation of the dynamic compression stimuli. In absorptive heterogeneity testing, we reconstructed the absorption coefficients of transparent polypropylene tubing circulated with a skim milk-India ink mixture and embedded in a gel wax tissue simulating phantom. High linear correlations (R-2 greater than 0.989) were observed between the reconstructed and the measured absorption coefficients of the embedded tubing. In dynamic compression testing, five volunteer operators generated ten successive compression sessions by compressing the idNIRUS imager on a breast self examination wearable model following the computer simulated pressure profile. The manually generated pressure profiles demonstrated an accuracy of 95.7% and operator-dependent variation of less than 5%. The results of the current benchtop tests will help to optimize the most appropriate testing conditions for our future planned clinical trial.
引用
收藏
页码:471 / 481
页数:11
相关论文
共 50 条
  • [21] Evaluation of suspicious breast lesions with diffusion kurtosis MR imaging and connection with prognostic factors
    Yang, Zhen Lu
    Li, Yan
    Zhan, Chen Ao
    Hu, Yi Qi
    Guo, Yi Hao
    Xia, Li Ming
    Ai, Tao
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 145
  • [22] Diffusion-weighted imaging in the characterization of breast lesions
    Sivrioglu, Ali Kemal
    Mutlu, Hakan
    Kara, Kemal
    Sonmez, Guener
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (03) : 851 - 851
  • [23] Accuracy of diffusion kurtosis imaging in characterization of breast lesions
    Christou, Alexandra
    Ghiatas, Abraham
    Priovolos, Dimitrios
    Veliou, Konstantia
    Bougias, Haralambos
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1073):
  • [24] Design and characterization of a handheld multimodal imaging device for the assessment of oral epithelial lesions
    Higgins, Laura M.
    Pierce, Mark C.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (08)
  • [25] A new needle system for preoperative localisation and core biopsies of suspicious breast lesions identified by magnetic resonance imaging.
    Heinig, A
    HeywangKobrunner, SH
    Viehweg, P
    Schaumloffel, U
    Heske, N
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (04): : 342 - 345
  • [26] Diffusion-weighted imaging versus dynamic contrast-enhanced MRI: a new horizon for characterisation of suspicious breast lesions
    El Ameen, N. F.
    Gawad, E. A. Abdel
    Ghany, H. S. Abdel
    CLINICAL RADIOLOGY, 2021, 76 (01) : 80.e1 - 80.e8
  • [27] A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
    Ronald X Xu
    Donn C Young
    Jimmy J Mao
    Stephen P Povoski
    Breast Cancer Research, 9
  • [28] A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions
    Xu, Ronald X.
    Young, Donn C.
    Mao, Jimmy J.
    Povoski, Stephen P.
    BREAST CANCER RESEARCH, 2007, 9 (06):
  • [29] Design and characterization of a high performance transceiver integrated PMUTs array for breast cancer imaging
    Jia, Licheng
    Liang, Yong
    Zhang, Guojun
    Wang, Renxin
    He, Changde
    Yang, Yuhua
    Cui, Jiangong
    Wu, Guoqiang
    Zhang, Wendong
    MEASUREMENT, 2024, 238
  • [30] Suspicious Breast Lesions Detected at 3.0 T Magnetic Resonance Imaging: Clinical and Histological Outcomes
    Johnson, Karen S.
    Baker, Jay A.
    Lee, Sheila S.
    Soo, Mary S.