An Integrated System for 3D Hip Joint Reconstruction from 2D X-rays: A Preliminary Validation Study

被引:17
|
作者
Schumann, Steffen [1 ]
Liu, Li [1 ]
Tannast, Moritz [2 ]
Bergmann, Mathias [3 ]
Nolte, Lutz-P. [1 ]
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ISTB, CH-3014 Bern, Switzerland
[2] Univ Bern, Dept Orthoped, Inselspital, CH-3014 Bern, Switzerland
[3] Univ Bern, Inst Anat, CH-3014 Bern, Switzerland
关键词
X-ray image; Calibration; Statistical shape model; 3D surface model; Proximal femur; Pelvis; CT;
D O I
10.1007/s10439-013-0822-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.
引用
收藏
页码:2077 / 2087
页数:11
相关论文
共 50 条
  • [21] 3D shape reconstruction from 2D images
    Hirano, Daisuke
    Funayama, Yusuke
    Maekawa, Takashi
    Computer-Aided Design and Applications, 2009, 6 (05): : 701 - 710
  • [22] 3D X-rays for quality control and SPC
    不详
    SENSOR REVIEW, 2007, 27 (01) : 62 - 63
  • [23] 3D imaging of cells with soft x-rays
    Larabell, Carolyn
    McDermott, Gerry
    LeGros, Mark
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [24] X-rays used to watch spins in 3D
    Peter Fischer
    Nature, 2017, 547 : 290 - 291
  • [25] 3X-Knee: A Novel Technology for 3D Preoperative Planning and Postoperative Evaluation of TKA Based on 2D X-Rays
    Zheng, Guoyan
    Alcoltekin, Alper
    Thelen, Benedikt
    Nolte, Lutz-P
    INTELLIGENT ORTHOPAEDICS: ARTIFICIAL INTELLIGENCE AND SMART IMAGE-GUIDED TECHNOLOGY FOR ORTHOPAEDICS, 2018, 1093 : 93 - 103
  • [26] 3D Reconstruction of 2D Crystals
    Zeng, Xiangyan
    Glover, James Ervin
    Hughes, Owen
    Stahlberg, Henning
    PROCEEDINGS OF THE 49TH ANNUAL ASSOCIATION FOR COMPUTING MACHINERY SOUTHEAST CONFERENCE (ACMSE '11), 2011, : 160 - 165
  • [27] 3D reconstruction for 2D PET
    Erlandsson, K
    Strand, SE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (02): : 369 - 374
  • [28] Sequential 3D analysis of patellofemoral kinematics from biplanar x-rays: In vitro validation protocol
    Dagneaux, L.
    Thoreux, P.
    Eustache, B.
    Canovas, F.
    Skalli, W.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (07) : 811 - 818
  • [29] Integrated 2D and 3D mammography
    Sumkin, Jules H.
    LANCET ONCOLOGY, 2013, 14 (08): : E292 - E293
  • [30] Reconstruction of 3D catheter paths from 2D X-ray projections
    Bender, HJ
    Männer, R
    Poliwoda, C
    Roth, S
    Walz, M
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 981 - 989