An Integrated System for 3D Hip Joint Reconstruction from 2D X-rays: A Preliminary Validation Study

被引:17
|
作者
Schumann, Steffen [1 ]
Liu, Li [1 ]
Tannast, Moritz [2 ]
Bergmann, Mathias [3 ]
Nolte, Lutz-P. [1 ]
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ISTB, CH-3014 Bern, Switzerland
[2] Univ Bern, Dept Orthoped, Inselspital, CH-3014 Bern, Switzerland
[3] Univ Bern, Inst Anat, CH-3014 Bern, Switzerland
关键词
X-ray image; Calibration; Statistical shape model; 3D surface model; Proximal femur; Pelvis; CT;
D O I
10.1007/s10439-013-0822-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.
引用
收藏
页码:2077 / 2087
页数:11
相关论文
共 50 条
  • [1] An Integrated System for 3D Hip Joint Reconstruction from 2D X-rays: A Preliminary Validation Study
    Steffen Schumann
    Li Liu
    Moritz Tannast
    Mathias Bergmann
    Lutz-P. Nolte
    Guoyan Zheng
    Annals of Biomedical Engineering, 2013, 41 : 2077 - 2087
  • [2] 2D and 3D Terahertz Imaging and X-Rays CT for Sigillography Study
    Fabre, M.
    Durand, R.
    Bassel, L.
    Recur, B.
    Balacey, H.
    Sleiman, J. Bou
    Perraud, J. -B.
    Mounaix, P.
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2017, 38 (04) : 483 - 494
  • [3] 2D and 3D Terahertz Imaging and X-Rays CT for Sigillography Study
    M. Fabre
    R. Durand
    L. Bassel
    B. Recur
    H. Balacey
    J. Bou Sleiman
    J.-B. Perraud
    P. Mounaix
    Journal of Infrared, Millimeter, and Terahertz Waves, 2017, 38 : 483 - 494
  • [4] Artificial Intelligence for 3D Reconstruction from 2D Panoramic X-rays to Assess Maxillary Impacted Canines
    Minhas, Sumeet
    Wu, Tai-Hsien
    Kim, Do-Gyoon
    Chen, Si
    Wu, Yi-Chu
    Ko, Ching-Chang
    DIAGNOSTICS, 2024, 14 (02)
  • [5] Coupling 2D/3D Registration Method and Statistical Model to Perform 3D Reconstruction from Partial X-Rays Images Data
    Cresson, Thierry
    Chay, Ramnada
    Branchaud, Dominic
    Humbert, Ludovic
    Godbout, Benoit
    Aubert, Benjamin
    Skalli, Wafa
    De Guise, Jacques A.
    RESEARCH INTO SPINAL DEFORMITIES 7, 2010, 158 : 215 - 215
  • [6] Coupling 2D/3D registration method and statistical model to perform 3D reconstruction from partial x-rays images data
    Cresson, T.
    Chav, R.
    Branchaud, D.
    Humbert, L.
    Godbout, B.
    Aubert, B.
    Skalli, W.
    De Guise, J. A.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1008 - 1011
  • [7] From 3D to 2D: Transferring knowledge for rib segmentation in chest X-rays
    Oliveira, Hugo
    Mota, Virginia
    Machado, Alexei M. C.
    dos Santos, Jefersson A.
    PATTERN RECOGNITION LETTERS, 2020, 140 : 10 - 17
  • [8] 3D reconstruction of the rib cage from biplanar X-rays
    Laporte, S
    Skalli, W
    Aubert, B
    Bertrand, S
    Mitton, D
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1275 - 1275
  • [9] Comparison of 3D and 2D characterization of spinal geometry from biplanar X-rays: a large cohort study
    Hu, Zongshan
    Vergari, Claudio
    Gajny, Laurent
    Liu, Zhen
    Lam, Tsz-Ping
    Zhu, Zezhang
    Qiu, Yong
    Man, Gene C. W.
    Yeung, Kwong-Hang
    Chu, Winnie C. W.
    Cheng, Jack C. Y.
    Skalli, Wafa
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (07) : 3306 - 3313
  • [10] Single-image Tomography: 3D Volumes from 2D Cranial X-Rays
    Henzler, Phlipp
    Rasche, Volker
    Ropinski, Timo
    Ritschel, Tobias
    COMPUTER GRAPHICS FORUM, 2018, 37 (02) : 377 - 388