Assessing radiotracer kinetics in the Langendorff perfused heart

被引:11
|
作者
Mariotti, Erika [1 ]
Veronese, Mattia [2 ]
Dunn, Joel T. [1 ]
Medina, Rodolfo A. [1 ]
Blower, Philip J. [1 ]
Southworth, Richard [1 ]
Eykyn, Thomas R. [1 ,3 ,4 ,5 ]
机构
[1] St Thomas Hosp, Kings Coll London, Div Imaging Sci & Biomed Engn, London SE1 7EH, England
[2] Kings Coll London, Inst Psychiat, London SE5 8AF, England
[3] Royal Marsden NHS Trust, CRUK, Surrey SM2 5NG, England
[4] Royal Marsden NHS Trust, EPSRC Canc Imaging Ctr, Surrey SM2 5NG, England
[5] Inst Canc Res, Surrey SM2 5NG, England
来源
EJNMMI RESEARCH | 2013年 / 3卷
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
PET; Spectral analysis; Kinetic modelling; F-18]-FDG; F-18]-FMISO; Perfused heart; POSITRON EMISSION TOMOGRAPHY; SPECTRAL-ANALYSIS; RAT-HEART; HYPOXIA; ISCHEMIA; TRACER; BRAIN; BLOOD; MODEL;
D O I
10.1186/2191-219X-3-74
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The Langendorff perfused heart is a physiologically relevant and controllable model with potential for assessing the pharmacokinetics of new radiotracers under a range of pathophysiological conditions.. We assess the feasibility of extending the methods validated for in vivo PET data analysis to the characterisation of PET tracer kinetics applied to Langendorff perfused hearts. Methods: Monte Carlo simulations were used to study the accuracy and reproducibility of linear and non-linear spectral analysis (SA/NLSA), the Patlak graphical method and normalised tissue activity (NA). The methods were used to analyse time-activity curves of two widely used PET tracers, [F-18]-FDG and [F-18]-FMISO, acquired ex vivo from Langendorff perfused rat hearts under normoxic and hypoxic conditions. Results: Monte Carlo simulations showed NLSA to be superior to SA in identifying and quantifying the presence of irreversible trapping component (alpha(0)), for low values of alpha(0). The performance of NLSA and SA for high values of trapping was comparable. NLSA was also more precise than SA in determining the absence of trapping over the range of simulated kinetics and SNR. Simulations also suggest that the semi-quantitative method NA is adequate for the evaluation of trapping, and it was found to be more accurate than Patlak. The values of alpha(0) estimated with NLSA from the time series of both [F-18]-FDG and [F-18]-FMISO increased significantly from normoxia to hypoxia in agreement with previous studies. The values of trapping derived using SA increased but not significantly, reflecting the larger error associate with this method. Patlak estimated from the experimental datasets increased from normoxia to hypoxia but was not significant. NA estimated from the [F-18]-FDG data increased from normoxia to hypoxia, but was not significant, whilst NA calculated for [F-18]-FMISO time-activity curves increased significantly. Conclusions: Monte Carlo simulations suggested that spectral-based quantitative analysis methods are adequate for the kinetic characterisation of time-activity curves acquired ex vivo from perfused hearts. The uptake rate Patlak and the index NA also represent a good alternative to the SA and NLSA algorithms when the aim of the kinetic analysis is to measure changes in the amount of tracer trapped in the irreversible compartment in response to external stimuli. For low levels of trapping, NLSA and NA were subject to lower errors than SA and Patlak, respectively.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [21] Protection induced by a brief ischemic episode in the Langendorff perfused rat heart
    Schjott, J
    Brurok, H
    Berg, K
    Jynge, P
    ACADEMIC RADIOLOGY, 1996, 3 (08) : 645 - 650
  • [22] Intracellular and intercellular mitochondrial membrane potential oscillations in the Langendorff perfused heart
    Slodzinski, MK
    Aon, M
    O'Rourke, B
    BIOPHYSICAL JOURNAL, 2004, 86 (01) : 461A - 461A
  • [23] Successful Langendorff-perfused Isolated Heart Preparation in Neonatal Mice
    Barajas, Matthew
    Levy, Richard J.
    Griffiths, Keren K.
    ANESTHESIA AND ANALGESIA, 2020, 130 : 119 - 120
  • [24] ACTIVATION OF THE LANGENDORFF PERFUSED RAT-HEART UNDER DEPOLARIZING CONDITIONS
    ABAURRE, PF
    STEFANON, I
    TRINDADE, JD
    LEITE, CM
    VASSALLO, DV
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 1990, 23 (08) : 735 - 738
  • [25] MULTINUCLEAR NMR-STUDIES OF THE LANGENDORFF PERFUSED RAT-HEART
    JELICKS, LA
    GUPTA, RK
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1989, 264 (26) : 15230 - 15235
  • [26] Is rate-pressure product of any use in the isolated rat heart? Assessing cardiac "effort' and oxygen consumption in the Langendorff-perfused heart
    Aksentijevic, Dunja
    Lewis, Hannah R.
    Shattock, Michael J.
    EXPERIMENTAL PHYSIOLOGY, 2016, 101 (02) : 282 - 294
  • [27] Contractility measurements in rat heart: Comparison of isolated myocytes and Langendorff-perfused whole heart
    Gao, BaoXi
    Qu, Yusheng
    Fang, Mei
    Vargas, Hugo
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2013, 68 (01) : E27 - E27
  • [28] Functional properties and responses to ischaemia-reperfusion in Langendorff perfused mouse heart
    Headrick, JP
    Peart, J
    Hack, B
    Flood, A
    Matherne, GP
    EXPERIMENTAL PHYSIOLOGY, 2001, 86 (06) : 703 - 716
  • [29] ATRIAL NATRIURETIC FACTOR IN THE LANGENDORFF PERFUSED CORONARY VASCULATURE OF THE RABBIT ISOLATED HEART
    KLAIR, SS
    LOUTTIT, JB
    CHARLTON, PA
    LIFE SCIENCES, 1989, 45 (25) : 2477 - 2483
  • [30] Effect of copper on Langendorff perfused guinea pig heart during ischaemia and reperfusion
    Lin, H
    Jeremy, JY
    Suleiman, MS
    JOURNAL OF PHYSIOLOGY-LONDON, 1998, 511P : 89P - 90P