Assessing radiotracer kinetics in the Langendorff perfused heart

被引:11
|
作者
Mariotti, Erika [1 ]
Veronese, Mattia [2 ]
Dunn, Joel T. [1 ]
Medina, Rodolfo A. [1 ]
Blower, Philip J. [1 ]
Southworth, Richard [1 ]
Eykyn, Thomas R. [1 ,3 ,4 ,5 ]
机构
[1] St Thomas Hosp, Kings Coll London, Div Imaging Sci & Biomed Engn, London SE1 7EH, England
[2] Kings Coll London, Inst Psychiat, London SE5 8AF, England
[3] Royal Marsden NHS Trust, CRUK, Surrey SM2 5NG, England
[4] Royal Marsden NHS Trust, EPSRC Canc Imaging Ctr, Surrey SM2 5NG, England
[5] Inst Canc Res, Surrey SM2 5NG, England
来源
EJNMMI RESEARCH | 2013年 / 3卷
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
PET; Spectral analysis; Kinetic modelling; F-18]-FDG; F-18]-FMISO; Perfused heart; POSITRON EMISSION TOMOGRAPHY; SPECTRAL-ANALYSIS; RAT-HEART; HYPOXIA; ISCHEMIA; TRACER; BRAIN; BLOOD; MODEL;
D O I
10.1186/2191-219X-3-74
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The Langendorff perfused heart is a physiologically relevant and controllable model with potential for assessing the pharmacokinetics of new radiotracers under a range of pathophysiological conditions.. We assess the feasibility of extending the methods validated for in vivo PET data analysis to the characterisation of PET tracer kinetics applied to Langendorff perfused hearts. Methods: Monte Carlo simulations were used to study the accuracy and reproducibility of linear and non-linear spectral analysis (SA/NLSA), the Patlak graphical method and normalised tissue activity (NA). The methods were used to analyse time-activity curves of two widely used PET tracers, [F-18]-FDG and [F-18]-FMISO, acquired ex vivo from Langendorff perfused rat hearts under normoxic and hypoxic conditions. Results: Monte Carlo simulations showed NLSA to be superior to SA in identifying and quantifying the presence of irreversible trapping component (alpha(0)), for low values of alpha(0). The performance of NLSA and SA for high values of trapping was comparable. NLSA was also more precise than SA in determining the absence of trapping over the range of simulated kinetics and SNR. Simulations also suggest that the semi-quantitative method NA is adequate for the evaluation of trapping, and it was found to be more accurate than Patlak. The values of alpha(0) estimated with NLSA from the time series of both [F-18]-FDG and [F-18]-FMISO increased significantly from normoxia to hypoxia in agreement with previous studies. The values of trapping derived using SA increased but not significantly, reflecting the larger error associate with this method. Patlak estimated from the experimental datasets increased from normoxia to hypoxia but was not significant. NA estimated from the [F-18]-FDG data increased from normoxia to hypoxia, but was not significant, whilst NA calculated for [F-18]-FMISO time-activity curves increased significantly. Conclusions: Monte Carlo simulations suggested that spectral-based quantitative analysis methods are adequate for the kinetic characterisation of time-activity curves acquired ex vivo from perfused hearts. The uptake rate Patlak and the index NA also represent a good alternative to the SA and NLSA algorithms when the aim of the kinetic analysis is to measure changes in the amount of tracer trapped in the irreversible compartment in response to external stimuli. For low levels of trapping, NLSA and NA were subject to lower errors than SA and Patlak, respectively.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [1] Assessing radiotracer kinetics in the Langendorff perfused heart
    Erika Mariotti
    Mattia Veronese
    Joel T Dunn
    Rodolfo A Medina
    Philip J Blower
    Richard Southworth
    Thomas R Eykyn
    EJNMMI Research, 3
  • [2] Development and validation of an isolated perfused Langendorff heart model for the assessment of PET radiotracer kinetics
    McCarthy, Brian
    Riley, Amanda
    Chang, Po-Cheng
    Skill, James
    Payne, Ronald
    Hutchins, Gary
    Territo, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [3] Development and validation of an isolated perfused Langendorff heart model for the assessment of PET radiotracer kinetics
    McCarthy, Brian
    Riley, Amanda
    Chang, Po-Cheng
    Skill, James
    Payne, Ronald
    Hutchins, Gary
    Territo, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [4] LANGENDORFF AND THE PERFUSED HEART
    MARSH, NA
    JOURNAL OF PHYSIOLOGY-LONDON, 1979, 291 (JUN): : P3 - P4
  • [5] REAPPRAISAL OF THE LANGENDORFF ISOLATED PERFUSED HEART
    SINGI, G
    COELHOANDRADE, R
    FREIREMAIA, L
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 1981, 14 (06) : 435 - 435
  • [6] The blockade of If in isolated (Langendorff perfused) heart
    Zefirov, T. L.
    Kuptsova, A. M.
    Zefirova, T. P.
    Faskhutdinov, L. I.
    Ziyatdinova, N. I.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2018, 48 : 140 - 140
  • [7] THE LANGENDORFF PERFUSED HEART - A TEACHING VIDEO
    ALLEN, DG
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1992, 24 (06) : R6 - R6
  • [8] CARDIAC DYNAMICS OF THE LANGENDORFF PERFUSED HEART
    TROUVE, R
    NAHAS, G
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1985, 180 (02): : 303 - 311
  • [9] CHRONOINOTROPIC EFFECTS IN LANGENDORFF PERFUSED RAT HEART
    Dvornikov, A. V.
    Chan, C. K.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2012, (02) : 7 - 11
  • [10] Monocationic radiotracer kinetics and myocardial infarct size: a perfused rat heart study
    Okada, David R.
    Liu, Zhonglin
    Beju, Delia
    Okada, Robert D.
    Johnson, Gerald, III
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (07) : 617 - 627