Direct microfabrication using an X-ray micro-beam

被引:2
|
作者
Katoh, T
Zhang, YP
Kagoshima, Y
Tsusaka, Y
Matsui, J
机构
[1] Sumitomo Heavy Ind Ltd, Tokyo 1888585, Japan
[2] Himeji Inst Technol, Himeji, Hyogo 6791297, Japan
关键词
direct writing; micro-beam; X-ray lens; PTFE; PMMA; synchrotron radiation;
D O I
10.1016/S0924-4247(02)00011-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A micro-beam of hard X-ray (10 keV) as small as 5 mum in diameter has been generated using a single refractive lens (SRL) and been applied for direct writing, which may find possible applications in three-dimensional (3D) micro-fabrication. The refractive lenses are parabolic-shaped concave lenses with a radius of 4 pm and an aperture of 179 pm and have been produced using our high aspect-ratio techniques with synchrotron radiation (SR). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:725 / 728
页数:4
相关论文
共 50 条
  • [21] Effects of Synchrotron X-Ray Micro-beam Irradiation on Normal Mouse Ear Pinnae
    Potez, Marine
    Bouchet, Audrey
    Wagner, Jeannine
    Donzelli, Mattia
    Brauer-Krisch, Elke
    Hopewell, John W.
    Laissue, Jean
    Djonov, Valentin
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 101 (03): : 680 - 689
  • [22] X-Ray Micro-Beam Diffraction Determination of Full Stress Tensors in Cu TSVs
    Okoro, Chukwudi
    Levine, Lyle E.
    Xu, Ruqing
    Tischler, Jonathan Z.
    Liu, Wenjun
    Kirillov, Oleg
    Hummler, Klaus
    Obeng, Yaw S.
    2013 IEEE 63RD ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2013, : 648 - 652
  • [23] X-ray micro-beam characterization of lattice rotations and distortions due to an individual dislocation
    Felix Hofmann
    Brian Abbey
    Wenjun Liu
    Ruqing Xu
    Brian F. Usher
    Eugeniu Balaur
    Yuzi Liu
    Nature Communications, 4
  • [24] Synchrotron X-ray micro-beam studies of ancient Egyptian make-up
    Martinetto, P
    Anne, M
    Dooryhée, E
    Drakopoulos, M
    Dubus, M
    Salomon, J
    Simionovici, A
    Walter, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 744 - 748
  • [25] Analysis of hydroxyapatite (HAp) texture in regenerated hard tissues using micro-beam X-ray diffractometer technique
    Nakano, T
    Kaibara, K
    Tabata, Y
    Nagata, N
    Enomoto, S
    Marukawa, E
    Umakoshi, Y
    TISSUE ENGINEERING FOR THERAPEUTIC USE 6, 2002, 1243 : 95 - 104
  • [26] A compact micro-beam system using a tapered glass capillary for proton-induced X-ray radiography
    Hasegawa, Jun
    Shiba, Shigeki
    Fukuda, Hitoshi
    Oguri, Yoshiyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (10): : 2125 - 2129
  • [27] Structural analysis of cell membrane complex of a hair fibre by micro-beam X-ray diffraction
    Ohta, N
    Oka, T
    Inoue, K
    Yagi, N
    Kato, S
    Hatta, I
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2005, 38 : 274 - 279
  • [28] Erratum: X-ray micro-beam characterization of lattice rotations and distortions due to an individual dislocation
    Felix Hofmann
    Brian Abbey
    Wenjun Liu
    Ruqing Xu
    Brian F. Usher
    Eugeniu Balaur
    Yuzi Liu
    Nature Communications, 5
  • [29] Preliminary investigation of trace element in Pterygium using Synchrotron radiation micro-beam X-ray fluorescence analysis (μ-XRF)
    Xie, Q.
    Peng, L.
    Cai, F.
    Li, Ai G.
    Yang, K.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [30] Physiologically gated micro-beam radiation therapy using electronically controlled field emission x-ray source array
    Chtcheprov, Pavel
    Hadsell, Michael
    Burk, Laurel
    Ger, Rachel
    Zhang, Lei
    Yuan, Hong
    Lee, Yueh Z.
    Chang, Sha
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671