Comparison of CID versus ETD-based MS/MS fragmentation for the analysis of doubly derivatized steroids

被引:6
|
作者
Juang, Yu-Min [1 ]
She, Tzu-Fang [1 ]
Chen, Hui-Yi [2 ]
Lai, Chien-Chen [1 ,3 ,4 ]
机构
[1] Natl Chung Hsing Univ, Inst Mol Biol, Taichung 402, Taiwan
[2] Natl Chung Hsing Univ, Ctr Biotechnol, Taichung 402, Taiwan
[3] China Med Univ, Grad Inst Chinese Med Sci, Taichung, Taiwan
[4] Natl Chung Hsing Univ, Rong Hsing Res Ctr Translat Med, Taichung 402, Taiwan
来源
JOURNAL OF MASS SPECTROMETRY | 2013年 / 48卷 / 12期
关键词
mass spectrometry; MS/MS; electron transfer dissociation; collision-induced dissociation; steroids; ELECTRON-TRANSFER DISSOCIATION; ASSISTED LASER DESORPTION/IONISATION; TANDEM MASS-SPECTROMETRY; CHOLESTEROL; IONIZATION; OXYSTEROLS; EXTRACTION; ESTROGENS;
D O I
10.1002/jms.3300
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization coupled with collision-induced dissociation (CID) and tandem mass spectrometry (MS/MS) is a commonly used technique to analyze the chemical composition of steroids. However, steroids are structurally similar compounds, making it difficult to interpret their product-ion spectra. Electron transfer dissociation (ETD), a relatively new technique for protein and peptide fragmentation, has been shown to provide more detailed structural information. In this study, we compared the ability of CID with that of ETD to differentiate between eight 3,20-dioxosteroids that had been derivatizated with a quaternary ammonium salt, Girard reagent P (GirP), at room temperature or after exposure to microwave irradiation to generate doubly charged ions. We found that the derivatization of steroid with GirP hydrazine occurred in less than 10min when the reaction was carried out in the presence of microwave irradiation compared to 30min when the reaction was carried out at room temperature. According to the MS/MS spectra, CID provided rich, structurally informative ions; however, the spectra were complex, thereby complicating the peak assignment. In contrast, ETD generated simpler spectra, making it easier to recognize individual peaks. Remarkably, both CID and ETD were allowed to differentiate of steroid isomers, 17-hydroxyprogesterone (17OHP) and deoxycorticosterone (DOC), but the signature ions obtained from CID were less intense than those generated by ETD, which generated much clearer spectra. These results indicate that ETD in conjunction with CID can provide more structural information for precise characterization of steroids. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1349 / 1356
页数:8
相关论文
共 50 条
  • [1] Comparison of CID Versus ETD Based MS/MS Fragmentation for the Analysis of Protein Ubiquitination
    Sobott, Frank
    Watt, Stephen J.
    Smith, Julia
    Edelmann, Mariola J.
    Kramer, Holger B.
    Kessler, Benedikt M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (09) : 1652 - 1659
  • [2] Effectiveness of CID, HCD, and ETD with FT MS/MS for Degradomic-Peptidomic Analysis: Comparison of Peptide Identification Methods
    Shen, Yufeng
    Tolic, Nikola
    Xie, Fang
    Zhao, Rui
    Purvine, Samuel O.
    Schepmoes, Athena A.
    Ronald, J. Moore
    Anderson, Gordon A.
    Smith, Richard D.
    JOURNAL OF PROTEOME RESEARCH, 2011, 10 (09) : 3929 - 3943
  • [3] Sequencing-Grade De novo Analysis of MS/MS Triplets (CID/HCD/ETD) From Overlapping Peptides
    Guthals, Adrian
    Clauser, Karl R.
    Frank, Ari M.
    Bandeira, Nuno
    JOURNAL OF PROTEOME RESEARCH, 2013, 12 (06) : 2846 - 2857
  • [4] New approach for characterization of post translational modified peptides using ion trap MS with combined ETD/CID fragmentation
    Hartmer, R
    Lubeck, M
    LC GC EUROPE, 2005, : 11 - 13
  • [5] New approach for characterization of post-translationally modified peptides using ion trap MS with combined ETD-CID fragmentation
    Hartmer, R
    Lubeck, M
    LC GC NORTH AMERICA, 2005, : 14 - 14
  • [6] Proteome Analysis of Sorangium cellulosum Employing 2D-HPLC-MS/MS and Improved Database Searching Strategies for CID and ETD Fragment Spectra
    Leinenbach, Andreas
    Hartmer, Ralf
    Lubeck, Markus
    Kneissl, Benny
    Elnakady, Yasser A.
    Baessmann, Carsten
    Mueller, Rolf
    Huber, Christian G.
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (09) : 4350 - 4361
  • [7] Derivatized versus non-derivatized LC-MS/MS techniques for the analysis of estrogens and estrogen-like endocrine disruptors in human plasma
    Vitku, J.
    Horackova, L.
    Kolatorova, L.
    Duskova, M.
    Skodova, T.
    Simkova, M.
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2023, 260
  • [8] Analysis for clonidine by LC/MS/MS, and a comparison of patient values using LC/MS/MS versus GC/NPD.
    McMullin, MM
    Diamond, FX
    Monahan, R
    CLINICAL CHEMISTRY, 1998, 44 : A86 - A86
  • [9] Comparison of proteome analysis by HPLC-Chip/MS versus nanospray LC/MS
    Vollmer, M
    Miller, C
    Gauthier, GL
    JOURNAL OF BIOTECHNOLOGY, 2005, 118 : S21 - S21
  • [10] Comparison of data analysis parameters and MS/MS fragmentation techniques for quantitative proteome analysis using isobaric peptide termini labeling (IPTL)
    Christian J. Koehler
    Magnus Ø. Arntzen
    Achim Treumann
    Bernd Thiede
    Analytical and Bioanalytical Chemistry, 2012, 404 : 1103 - 1114