A Monte-Carlo based model of the AX-PET demonstrator and its experimental validation

被引:5
|
作者
Solevi, P. [1 ]
Oliver, J. F. [1 ]
Gillam, J. E. [1 ]
Bolle, E. [2 ]
Casella, C. [3 ]
Chesi, E. [4 ]
De Leo, R. [5 ]
Dissertori, G. [3 ]
Fanti, V. [6 ,7 ]
Heller, M. [8 ]
Lai, M. [8 ]
Lustermann, W. [3 ]
Nappi, E. [5 ]
Pauss, F. [3 ]
Rudge, A. [4 ]
Ruotsalainen, U. [9 ]
Schinzel, D. [3 ]
Schneider, T. [8 ]
Seguinot, J. [8 ]
Stapnes, S. [2 ]
Weilhammer, P. [4 ]
Tuna, U. [9 ]
Joram, C. [8 ]
Rafecas, M. [1 ]
机构
[1] Univ Valencia, CSIC, IFIC, E-46071 Valencia, Spain
[2] Univ Oslo, Dept Phys, NO-0317 Oslo, Norway
[3] ETH, CH-8092 Zurich, Switzerland
[4] Ohio State Univ, Dept Phys, Columbus, OH 43210 USA
[5] Ist Nazl Fis Nucl, Sez Bari, I-70122 Bari, Italy
[6] Univ Cagliari, Cagliari, Italy
[7] Sezione Ist Nazl Fis Nucl, Cagliari, Italy
[8] CERN, PH Dept, CH-1211 Geneva, Switzerland
[9] Tampere Univ Technol, Dept Signal Proc, FI-33100 Tampere, Finland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 16期
关键词
SIMULATION TOOLKIT; GATE; SPECT; RECONSTRUCTION; MATRIX;
D O I
10.1088/0031-9155/58/16/5495
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
AX-PET is a novel PET detector based on axially oriented crystals and orthogonal wavelength shifter (WLS) strips, both individually read out by silicon photo-multipliers. Its design decouples sensitivity and spatial resolution, by reducing the parallax error due to the layered arrangement of the crystals. Additionally the granularity of AX-PET enhances the capability to track photons within the detector yielding a large fraction of inter-crystal scatter events. These events, if properly processed, can be included in the reconstruction stage further increasing the sensitivity. Its unique features require dedicated Monte-Carlo simulations, enabling the development of the device, interpreting data and allowing the development of reconstruction codes. At the same time the non-conventional design of AX-PET poses several challenges to the simulation and modeling tasks, mostly related to the light transport and distribution within the crystals and WLS strips, as well as the electronics readout. In this work we present a hybrid simulation tool based on an analytical model and a Monte-Carlo based description of the AX-PET demonstrator. It was extensively validated against experimental data, providing excellent agreement.
引用
收藏
页码:5495 / 5510
页数:16
相关论文
共 50 条
  • [41] Compression of a Monte-Carlo based system matrix for iterative reconstruction of PET images
    Rehfeld, N
    Alber, M
    Fippel, M
    Nüsslin, F
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3945 - 3947
  • [42] EVALUATING PRECISION PLANTING BASED ON A MONTE-CARLO PLANTER MODEL
    ROHRBACH, RP
    BARRE, HJ
    BRAZEE, RD
    TRANSACTIONS OF THE ASAE, 1971, 14 (06): : 1146 - &
  • [43] Model sensitivity analysis of Monte-Carlo based SEM simulations
    Arat, Kerim T.
    Hagen, Cornelis W.
    RESULTS IN PHYSICS, 2020, 19
  • [44] Validation of Monte-Carlo Beam Model for a Range of Small Fields in Heterogeneous Medium - A Measurement Based Study
    Karthikeyan, N.
    Ganesh, K. M.
    Sambasivaselli, R.
    Senniandavar, V.
    Sandeep, Jain
    MEDICAL PHYSICS, 2016, 43 (06) : 3548 - 3548
  • [45] IPA MODEL OF NEURAL NETWORK AND ITS MONTE-CARLO LEARNING ALGORITHM
    MU, G
    LU, M
    ZHAN, Y
    OPTIK, 1991, 89 (01): : 11 - 14
  • [46] A MONTE-CARLO METHOD FOR THE VALIDATION OF DISCRIMINATION ELLIPSE DATA
    ALDER, C
    JOURNAL OF THE SOCIETY OF DYERS AND COLOURISTS, 1981, 97 (12): : 514 - 517
  • [47] Bandit based Monte-Carlo planning
    Kocsis, Levente
    Szepesvari, Csaba
    MACHINE LEARNING: ECML 2006, PROCEEDINGS, 2006, 4212 : 282 - 293
  • [48] Development and validation of a Monte-Carlo simulation model of a preoperative patient testing center (PTC)
    Epstein, RH
    Gratch, DM
    Bell, SD
    Bartkowski, RR
    Caffrey, D
    ANESTHESIOLOGY, 1999, 91 (3A) : U483 - U483
  • [49] MONTE-CARLO SIMULATION FOR PROTON THERAPY MONITORING USING PET
    Ty, C. Van Ngoc
    De Marzi, L.
    Jan, S.
    Lestand, L.
    Ferrand, R.
    Comtat, C.
    Trebossen, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S527 - S528
  • [50] Monte-Carlo System Modeling for PET Reconstruction: a Rotator Approach
    Zhang, Long
    Vandenberghe, Stefaan
    Staelens, Steven
    Verhaeghe, J.
    Kawrakow, Iwan
    Lemahieu, Ignace
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4367 - +