Is the New AquaTrainer® Snorkel Valid for VO2 Assessment in Swimming?

被引:48
|
作者
Baldari, C. [1 ]
Fernandes, R. J. [2 ,3 ]
Meucci, M. [1 ]
Ribeiro, J. [2 ]
Vilas-Boas, J. P. [2 ,3 ]
Guidetti, L. [1 ]
机构
[1] Univ Rome Foro Ital, Dept Hlth Sci, I-00135 Rome, Italy
[2] Univ Porto, Fac Sport, Ctr Res Educ Innovat & Intervent Sport, P-4100 Oporto, Portugal
[3] Univ Porto, Porto Biomech Lab, P-4100 Oporto, Portugal
关键词
respiratory valves; K4b(2); oxygen consumption; energetics; OXYGEN-UPTAKE MEASUREMENTS; FRONT CRAWL; RESPIRATORY VALVE; TELEMETRY SYSTEM; GAS-ANALYSIS; EXERCISE; RELIABILITY; KINETICS;
D O I
10.1055/s-0032-1321804
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The Cosmed AquaTrainer (R) snorkel, in connection with the K4b(2) analyzer, is the most recent instrument used for real time gas analysis during swimming. This study aimed to test if a new AquaTrainer (R) snorkel with 2 (SV2) or 4 (SV4) valves is comparable to a standard face mask (Mask) being valid for real time gas analysis under controlled laboratory and swimming pool conditions. 9 swimmers performed 2 swimming and 3 cycling tests at 3 different workloads on separate days. Tests were performed in random order, at constant exercise load with direct turbine temperature measurements, breathing with Mask, SV4 and SV2 while cycling, and with SV2 and SV4 while swimming. A high agreement was obtained using Passing - Bablok regression analysis in oxygen consumption, carbon dioxide production, tidal volumes, pulmonary ventilation, expiratory fraction of oxygen and carbon dioxide, and heart rate comparing different conditions in swimming and cycling. Proportional and fixed differences were always rejected (95 % CI always contained the value 1 for the slope and the 0 for the intercept). In conclusion, the new SV2 AquaTrainer (R) snorkel, can be considered a valid device for gas analysis, being comparable to the Mask and the SV4 in cycling, and to the SV4 in swimming.
引用
收藏
页码:336 / 344
页数:9
相关论文
共 50 条
  • [21] Which Are The Best VO2 Sampling Intervals to Characterize Low to Severe Swimming Intensities?
    de Jesus, K.
    Guidetti, L.
    de Jesus, K.
    Vilas-Boas, J. P.
    Baldari, C.
    Fernandes, R. J.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2014, 35 (12) : 1030 - 1036
  • [22] Sigmoidal VO2 on-kinetics: A new pattern in VO2 responses at the lower district of extreme exercise domain
    Balci, Gorkem Aybars
    As, Hakan
    Ozkaya, Ozgur
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2020, 281
  • [23] VO2 Kinetics is Slower in Swimming than in Arm Cranking or Cycling in Trained Triathletes
    Millet, Gregoire P.
    Libicz, Sebastien
    Roels, Belle
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S237 - S238
  • [24] IS ASYMPTOTIC VO2 AN OBLIGATE DETERMINANT OF VO2 KINETICS DURING EXERCISE
    WHIPP, BJ
    DAVIS, JA
    STREMEL, RW
    CASABURI, R
    WASSERMAN, K
    FEDERATION PROCEEDINGS, 1978, 37 (03) : 865 - 865
  • [25] Synthesis of VO2(A) Nanostructures by a Hydrothermal Method and Their Transition to VO2(M)
    Zhong, Yalan
    Zhang, Yifu
    Liu, Xin
    Liu, Xinghai
    Huang, Chi
    Li, Houbin
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-3, 2011, 295-297 : 368 - +
  • [26] NEW GROWING METHOD FOR VO2 SINGLE CRYSTALS
    SASAKI, H
    WATANABE, A
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1964, 19 (09) : 1748 - +
  • [27] Body size and VO2 peak:: A new perspective?
    McCann, DJ
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2004, 25 (01) : 50 - 55
  • [28] Regulating the surface morphology and improving the thermochromic properties of VO2 films by introducing Cu-Ag and Cu-Zr nanoparticles into the VO2/VO2/VO2 structure
    Wang, Wei
    Qiao, Wentao
    Zhang, Cong
    Zhang, Shiqi
    Zong, Haitao
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (07):
  • [29] VO2 reserve -: A new method for exercise prescription
    Swain, DP
    ACSMS HEALTH & FITNESS JOURNAL, 1999, 3 (05) : 10 - 14
  • [30] A new approach to prepare VO2 (B) nanoribbons
    Liu, Xinghai
    Xie, Guangyong
    Huang, Chi
    Wu, Hanzheng
    Luo, Yunbai
    CHEMISTRY LETTERS, 2007, 36 (11) : 1366 - 1367