Compact amperometric solid-electrolyte sensor for detection of NO2 in ppb range

被引:0
|
作者
Miura, N
Ono, M
Shimanoe, K
Yamazoe, N
机构
关键词
NO2; sensor; amperometric sensor; solid electrolyte;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A solid-state amperometric sensor for NO2 was designed by attaching a Na+ conductor (NASICON) based device with an NaNO2 layer deposited on the counter electrode. With the sensing electrode being polarized at a constant potential relative to the reference Au electrode, electric current flowing through the device under exposure to NO2 was measured as the sensing signal. The current response was almost linear to the NO2 concentration in the range from 10 ppb to 1 ppm at 150 degrees C. The 90% response time to even 20 ppb NO2 was ca. 60 s. The NO2 sensitivity was hardly affected by the coexistence of CO2, H2O and O2. A sensing mechanism is proposed from the sensing characteristics obtained.
引用
收藏
页码:951 / 954
页数:4
相关论文
共 50 条
  • [21] Influence of the Solid-Electrolyte Ionic Material in a Potentiometric Sensor for Ethylene Detection
    Toldra-Reig, Fidel
    Pastor, Daniel
    Serra, Jose M.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (14) : B1343 - B1355
  • [22] Solid-electrolyte amperometric sensor for measuring NO in air, nitrogen, and nitrogen-oxygen gas mixtures
    A. S. Kalyakin
    A. N. Volkov
    L. A. Dunyushkina
    [J]. Ionics, 2021, 27 : 2697 - 2705
  • [23] Effect of the geometry of a working electrode on the behavior of a planar amperometric NO2 sensor based on solid polymer electrolyte
    Kubersky, P.
    Hamacek, A.
    Nespurek, S.
    Soukup, R.
    Vik, R.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 187 : 546 - 552
  • [24] Amperometric solid-state NO2 sensor based on plasticized PVC matrix containing a hydrophobic electrolyte
    Langmaier, J
    Opekar, F
    Samec, Z
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) : 1 - 6
  • [25] CO2 DETECTION WITH LITHIUM SOLID-ELECTROLYTE SENSORS
    IMANAKA, N
    MURATA, T
    KAWASATO, T
    ADACHI, G
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 476 - 479
  • [26] Noise in Amperometric NO2 Sensor
    Sedlak, Petr
    Sikula, Josef
    Sedlakova, Vlasta
    Chvatal, Milos
    Majzner, Jiri
    Vondra, Marek
    Kubersky, Petr
    Nespurek, Stanislav
    Hamacek, Ales
    [J]. 2013 22ND INTERNATIONAL CONFERENCE ON NOISE AND FLUCTUATIONS (ICNF), 2013,
  • [27] Amperometric gas sensors with detection limits in the low ppb range
    Hodgson, AWE
    Jacquinot, P
    Jordon, LR
    Hauser, PC
    [J]. ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) : 43 - 48
  • [28] A NOx sensor based on solid-electrolyte impedance transducer
    Shimizu, Youichi
    Takase, Satoko
    Koba, Daisuke
    [J]. MULTI-FUNCTIONAL MATERIALS AND STRUCTURES, PTS 1 AND 2, 2008, 47-50 : 479 - 482
  • [29] INTERNAL-REFERENCE SOLID-ELECTROLYTE OXYGEN SENSOR
    HAALAND, DM
    [J]. ANALYTICAL CHEMISTRY, 1977, 49 (12) : 1813 - 1817
  • [30] Amperometric solid-state sensor for NO and NO2 based on protonic conduction
    Alberti, G
    Cherubini, F
    Palombari, R
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 37 (03) : 131 - 134