Data analysis for Seebeck coefficient measurements

被引:132
|
作者
de Boor, J. [1 ]
Mueller, E. [1 ,2 ]
机构
[1] German Aerosp Ctr, Inst Mat Res, D-51147 Cologne, Germany
[2] Univ Giessen, Inst Inorgan & Analyt Chem, D-35392 Giessen, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2013年 / 84卷 / 06期
关键词
THERMOELECTRIC-MATERIALS; RESISTIVITY MEASUREMENTS; ELECTRICAL-RESISTIVITY; TEMPERATURE-RANGE; THERMOPOWER;
D O I
10.1063/1.4807697
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Seebeck coefficient is one of the key quantities of thermoelectric materials and routinely measured in various laboratories. There are, however, several ways to calculate the Seebeck coefficient from the raw measurement data. We compare these different ways to extract the Seebeck coefficient, evaluate the accuracy of the results, and show methods to increase this accuracy. We furthermore point out experimental and data analysis parameters that can be used to evaluate the trustworthiness of the obtained result. The shown analysis can be used to find and minimize errors in the Seebeck coefficient measurement and therefore increase the reliability of the measured material properties. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Uncertainty analysis of axial temperature and Seebeck coefficient measurements
    Yazdani, Sajad
    Kim, Hyun-Young
    Pettes, Michael Thompson
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (08):
  • [2] Seebeck coefficient measurements of lithium isotopes
    Surla, V.
    Tung, M.
    Xu, W.
    Andruczyk, D.
    Neumann, M.
    Ruzic, D. N.
    Mansfield, D.
    JOURNAL OF NUCLEAR MATERIALS, 2011, 415 (01) : 18 - 22
  • [3] AN AUTOMATIC TECHNIQUE FOR ACCURATE MEASUREMENTS OF SEEBECK COEFFICIENT
    BERGLUND, CN
    BEAIRSTO, RC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (01): : 66 - &
  • [4] Reliable measurements of the Seebeck coefficient on a commercial system
    Liu, Yintu
    Fu, Chenguang
    Xie, Hanhui
    Zhao, Xinbing
    Zhu, Tiejun
    JOURNAL OF MATERIALS RESEARCH, 2015, 30 (17) : 2670 - 2677
  • [5] Reliable measurements of the Seebeck coefficient on a commercial system
    Yintu Liu
    Chenguang Fu
    Hanhui Xie
    Xinbing Zhao
    Tiejun Zhu
    Journal of Materials Research, 2015, 30 : 2670 - 2677
  • [6] Experimental setup for the Seebeck and Nernst coefficient measurements
    Sharma, Shailja
    Yadav, C. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (12):
  • [7] Error Modeling of Seebeck Coefficient Measurements Using Finite-Element Analysis
    Joshua Martin
    Journal of Electronic Materials, 2013, 42 : 1358 - 1364
  • [8] Error Modeling of Seebeck Coefficient Measurements Using Finite-Element Analysis
    Martin, Joshua
    JOURNAL OF ELECTRONIC MATERIALS, 2013, 42 (07) : 1358 - 1364
  • [9] Modelling and uncertainty analysis of Seebeck coefficient measurements by using the finite element method
    Huang, K.
    Edler, F.
    Haupt, S.
    Ziolkowski, P.
    Stiewe, C.
    Mueller, E.
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 3500 - 3505
  • [10] HIGH-TEMPERATURE SEEBECK COEFFICIENT MEASUREMENTS ON SPINEL
    WOOD, C
    WOOSLEY, J
    SONDER, E
    WEEKS, RA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (03): : 386 - 386