Production of six-degrees-of-freedom (6DoF) navigable audio using 30 Ambisonic microphones

被引:1
|
作者
Mroz, Bartlomiej [1 ]
Kabacinski, Marek [2 ]
Ciotucha, Tomasz [2 ]
Ruminski, Andrzej [2 ]
Zernicki, Tomasz [2 ]
机构
[1] Gdansk Univ Technol, Multimedia Syst Dept, Gdansk, Poland
[2] Zylia Sp Zoo, Poznan, Poland
关键词
virtual reality; spatial audio; Ambisonics; sound source localization; six-degrees-of-freedom;
D O I
10.1109/I3DA48870.2021.9610970
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper describes a method for planning, recording, and post-production of six-degrees-of-freedom audio recorded with multiple 3rd order Ambisonic microphone arrays. The description is based on the example of recordings conducted in August 2020 with the Poznan Philharmonic Orchestra using 30 units of Zylia ZM-1S. A convenient way to prepare and organize such a big project is proposed - this involves details of stage planning, collecting needed equipment, management, and running the recording. Additionally, the placement of 2D and 360 cameras as well as the design of moving camera paths are described. Two use cases of the collected Ambisonic audio are proposed. The first one is a production of a virtual reality application using Unreal Engine 4 and Wwise. The second one uses a combination of the virtual scene from the previously mentioned application and a footage from a mobile, moving camera to create a so-called "walkthrough movie". The proposed approach for six-degrees-of-freedom Ambisonic interpolation was evaluated on listening tests. Those tests demonstrate that it is possible to recreate a navigable 3D audio taking into account Ambisonic only input and given assumptions for microphone placement.
引用
收藏
页数:5
相关论文
共 27 条
  • [21] An Actuation Acceleration-Based Kinematic Modeling and Parameter Identification Approach for a Six-Degrees-of-Freedom 6-PSU Parallel Robot With Joint Clearances
    Liu, Xin
    Qi, Chenkun
    Lin, Jianfeng
    Li, Dongjin
    Gao, Feng
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2025, 17 (01):
  • [22] 6DoF-3D: Efficient and accurate 3D object detection using six degrees-of-freedom for autonomous driving
    Li, Zhen
    Yang, Zijun
    Gao, Yuliang
    Du, Yuren
    Serikawa, Seiichi
    Zhang, Lifeng
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 238
  • [23] Development of active six-degrees-of-freedom micro-vibration control system using hybrid actuators comprising air actuators and giant magnetostrictive actuators
    Nakamura, Yoshiya
    Nakayama, Masanao
    Yasuda, Masashi
    Fujita, Takafumi
    SMART MATERIALS & STRUCTURES, 2006, 15 (04): : 1133 - 1142
  • [24] Biomechanics Analysis of the Lower Limbs in 20 Male Sprinters Using the International Society of Biomechanics Six-Degrees-of-Freedom Model and the Conventional Gait Model
    Ji, Youbo
    Xu, Rui
    Zuo, Hao
    Wang, Zhonghan
    Jin, Hui
    MEDICAL SCIENCE MONITOR, 2021, 27
  • [25] SET UP ACCURACY MEASURED WITH 6 DEGREES OF FREEDOM (DOF) INFORMATION FOR PELVIC RADIOTHERAPY USING TOMOTHERAPY ON-LINE IMAGE REGISTRATION
    Routsis, D.
    Dean, J.
    Kirby, R.
    Adams, L.
    Fairfoul, J.
    Thomas, S.
    Russell, S.
    Patterson, H.
    Rimmer, Y.
    Burnet, N.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S98 - S99
  • [26] Precision of Radiotherapy of Prostate with Rectum Balloon guided with 6 Degrees of Freedom (6-dof) by means of Cone Beam CT online: Evaluation of Dorsal Target Margin Abnormalities by using elastic Deformation as the Basis for an adaptive Radiotherapy
    Xydis, K.
    Abu Jawad, J.
    Poettgen, C.
    Stuschke, M.
    Levegruen, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 : S90 - S90
  • [27] Geometric accuracy evaluation of a six-degree-of-freedom (6-DoF) couch with cone beam computed tomography (CBCT) using a phantom and correlation study of the position errors in pelvic tumor radiotherapy
    Fu, Caofei
    Ma, Changsheng
    Shang, Dongping
    Qiu, Qingtao
    Meng, Huipeng
    Duan, Jinghao
    Yin, Yong
    TRANSLATIONAL CANCER RESEARCH, 2020, 9 (10) : 6005 - 6012