Measurements of chest wall volume variation during tidal breathing in the supine and lateral positions in healthy subjects

被引:11
|
作者
Nozoe, Masafumi [1 ]
Mase, Kyoshi [2 ]
Takashima, Sachie [2 ]
Matsushita, Kazuhiro [1 ]
Kouyama, Yusuke [1 ]
Hashizume, Hiromi [1 ]
Kawasaki, Yurina [3 ]
Uchiyama, Yuki [4 ]
Yamamoto, Noriyasu [5 ]
Fukuda, Yoshihiro [4 ]
Domen, Kazuhisa [6 ]
机构
[1] Hyogo Coll Med, Sasayama Med Ctr, Dept Rehabil, Sasayama, Hyogo, Japan
[2] Konan Womens Univ, Fac Nursing & Rehabil, Dept Phys Therapy, Kobe, Hyogo, Japan
[3] Konan Kakogawa Hosp, Dept Rehabil, Kobe, Hyogo, Japan
[4] Hyogo Coll Med, Dept Gen Med & Community Hlth Sci, Hyogo, Japan
[5] Hyogo Coll Med, Dept Funct Regenerat Sci, Hyogo, Japan
[6] Hyogo Coll Med, Dept Rehabil Med, Hyogo, Japan
关键词
Chest wall volume; Lateral position; Optoelectronic plethysmography; ELECTRICAL-IMPEDANCE TOMOGRAPHY; OPTOELECTRONIC PLETHYSMOGRAPHY; INTRAABDOMINAL PRESSURE; RIB CAGE; EXERCISE; VENTILATION; KINEMATICS; MECHANICS; MOTION; ADULTS;
D O I
10.1016/j.resp.2013.12.016
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: To study the feasibility and the laterality of measurements of chest wall volume variation during tidal breathing in the lateral position in healthy subjects. Methods: Eighteen normal subjects were studied. Chest wall volume changes were measured by opto-electronic plethysmography in the supine and right and left lateral positions during quiet breathing. The accuracy of measuring lung volume was also examined using hot wire spirometry in 10 of the subjects. Results: The measurement errors between lung volume changes and chest wall volume changes were not significantly different in all positions. There was no significant difference between right and left compartmental volume changes in the supine position. However, chest wall volume changes were lower on the dependent side in the lateral position than on the non-dependent side because of the decrease in abdominal rib cage and abdomen volume changes. Conclusion: Chest wall volume measurements during quiet breathing in the lateral position have high measuring accuracy and show laterality. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 42
页数:5
相关论文
共 46 条
  • [41] Computational fluid dynamics modeling of upper airway during tidal breathing using volume-gated MRI in OSAS and control subjects
    Persak, Steven C.
    Sin, Sanghun
    Arens, Raanan
    Wootton, David M.
    2010 IEEE 36TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2010,
  • [42] Approximate entropy showed greater tidal volume and breathing frequency variability during steady state exercise in healthy adolescents compared to adults
    Welch, Ryan
    Casey, Sarah
    Kolbe, John
    Kevin, Ellyett
    PHYSIOLOGY, 2023, 38
  • [43] Relationship between heart rate variability, blood pressure and arterial wall properties during air and oxygen breathing in healthy subjects
    Graff, Beata
    Szyndler, Anna
    Czechowicz, Krzysztof
    Kucharska, Wieslawa
    Graff, Grzegorz
    Boutouyrie, Pierre
    Laurent, Stephane
    Narkiewicz, Krzysztof
    AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2013, 178 (1-2): : 60 - 66
  • [44] The Accuracy of Tidal Volume Measured With a Smart Shirt During Tasks of Daily Living in Healthy Subjects: Cross-sectional Study
    Mannee, Denise
    de Jongh, Frans
    van Helvoort, Hanneke
    JMIR FORMATIVE RESEARCH, 2021, 5 (10)
  • [45] Middle cerebral artery blood flow velocity, end-tidal pCO2 and blood pressure in patients with obstructive sleep apnea and in healthy subjects during continuous positive airway pressure breathing
    Droste, DW
    Lüdemann, P
    Anders, F
    Kemény, V
    Thomas, M
    Krauss, JK
    Ringelstein, EB
    NEUROLOGICAL RESEARCH, 1999, 21 (08) : 737 - 741
  • [46] Difference in diaphragmatic motion during tidal breathing in a standing position between COPD patients and normal subjects: Time-resolved quantitative evaluation using dynamic chest radiography with flat panel detector system ("dynamic X-ray phrenicography")
    Yamada, Yoshitake
    Ueyama, Masako
    Abe, Takehiko
    Araki, Tetsuro
    Abe, Takayuki
    Nishino, Mizuki
    Jinzaki, Masahiro
    Hatabu, Hiroto
    Kudoh, Shoji
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 76 - 82