A Two-Step Self-calibration Method with Portable Measurement Devices for Industrial Robots Based on POE Formula

被引:2
|
作者
Gu, Lefeng [1 ,2 ]
Yang, Guilin [1 ,2 ]
Fang, Zaojun [1 ]
Shen, Wenjun [1 ,2 ]
Zheng, Tianjiang [1 ]
Chen, Chinyin [1 ]
Zhang, Chi [1 ]
机构
[1] Chinese Acad Sci, Zhejiang Key Lab Robot & Intelligent Mfg Equipmen, Ningbo Inst Mat Technol & Engn, Ningbo 315201, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Self-calibration; POE formula; Kinematic calibration; MODEL;
D O I
10.1007/978-3-030-27526-6_63
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A two-step self-calibration method based on portable calibration devices is proposed in this paper. In the first step, the distance errors in a large-range workspace is utilized to calibrate the manipulator. In the second step, the position errors is utilized to calibrate an external world frame to describe all the coordinate systems in a robot cell and further enhance the calibration results in the first step. For each step, a linear and simplified calibration model is then formulated by employing the local POE formula and introducing the position adjoint conversion matrix. Based on the calibration model, portable and cost-effective self-calibration devices are designed, which consist of a spherical center measuring device, a movable ball bar and Tri-ball plate. The calibration devices presented can obtain distance errors in a large-range workspace and position errors in a local workspace of a manipulator, which enhance the reliability of the calibration results and set an external reference frame. Finally, an accurate kinematic model with respect to the external user-defined frame is given, which enables the off-line programming to be more accurate and effective. The simulation results demonstrate that the proposed two-step self-calibration algorithm is effective and robust.
引用
收藏
页码:715 / 727
页数:13
相关论文
共 50 条
  • [31] Self-calibration method of precision shafting angle measurement error based on multiple reading heads
    Zhang, Run
    Bao, Wenhui
    Zhao, Huining
    Jia, Huakun
    Yu, Liandong
    [J]. TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053
  • [32] Geometric error self-calibration method of five-axis dispensing machine based on the product of exponentials formula
    Tang, Xianxing
    Zhou, Haibo
    Kuang, Lei
    [J]. MEASUREMENT, 2024, 231
  • [33] A two-step method for kinematic parameters calibration based on complete pose measurement-Verification on a heavy-duty robot
    Miao, Lei
    Zhang, Yongliang
    Song, Zhichao
    Guo, Yingjie
    Zhu, Weidong
    Ke, Yinglin
    [J]. ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2023, 83
  • [34] Measurement Method of Void Fraction in Narrow Channel Based on Two-step Morphological Image Method
    Pan L.
    Liu Y.
    Li W.
    Liu Y.
    [J]. Liu, Yang (liu_yang@tsinghua.edu.cn), 2018, Atomic Energy Press (52): : 2256 - 2262
  • [35] An Amplitude-phase Measurement Method of Phased Array Antenna Based on Self-Calibration RF Channel
    Chen Tengbo
    Zhang Lu
    Du Hailong
    [J]. 2018 10TH INTERNATIONAL CONFERENCE ON COMMUNICATION SOFTWARE AND NETWORKS (ICCSN), 2018, : 460 - 464
  • [36] Calibration method of anchor position in indoor environment based on two-step extended Kalman filter
    Tian, Xin
    Wei, Guoliang
    Zhou, Jun
    [J]. MULTIDIMENSIONAL SYSTEMS AND SIGNAL PROCESSING, 2021, 32 (04) : 1141 - 1158
  • [37] Calibration Technology on Binocular CCD Ranging System Based on Improving Tsai Two-step Method
    Zhang Lijuan
    Li Dongming
    Zhao Hui
    Wang Junnan
    [J]. PROCEEDINGS OF 2012 2ND INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND NETWORK TECHNOLOGY (ICCSNT 2012), 2012, : 247 - 251
  • [38] Calibration method of anchor position in indoor environment based on two-step extended Kalman filter
    Xin Tian
    Guoliang Wei
    Jun Zhou
    [J]. Multidimensional Systems and Signal Processing, 2021, 32 : 1141 - 1158
  • [39] A Low Noise CMOS Image Sensor with a 14-bit Two-Step Single-Slope ADC and a Column Self-Calibration Technique
    Lim, Woongtaek
    Hwang, Jongyoon
    Kim, Dongjoo
    Jeon, Shiwon
    Son, Suho
    Song, Minkyu
    [J]. 2014 21ST IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS (ICECS), 2014, : 48 - 51
  • [40] The self-calibration method based on grating-rulers used for 6-DOF motion measurement system
    Zhang, Ying
    Liu, Zhihua
    Zheng, Dezhi
    Cai, Chenguang
    [J]. MEASUREMENT, 2022, 204