Intra-aortic filtration - Capturing particulate emboll during aortic cross-clamping

被引:0
|
作者
Christenson, JT
Vala, DL
Licker, M
Sierra, J
Kalangos, A
机构
[1] Univ Hosp Geneva, Dept Cardiovasc Surg, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Dept Anesthesiol, CH-1211 Geneva, Switzerland
关键词
aortic cannula; aortic cross-clamping; atherosclerosis; cardiac surgical procedures/adverse effects; cardiopulmonary bypass; clamps; surgical; coronary artery bypass/surgery; embolism/prevention & control; filtration/methods/therapeutic use; heart valve diseases/surgery; postoperative complications;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Particulate emboli are an important factor in the development of complications after cardiac surgery. The use of an intra-aortic filter during aortic declamping has proved safe and effective in reducing the incidence of embolic complications. Because aortic cross-clamping is also associated with the risk of embolism, we measured the release of particulate emboli at the time of aortic cross-clamping and at declamping. We deployed intra-aortic filters (Edwards EMBOL-X(R) Slim Protection System) at 2 different times during 15 consecutive cardiac procedures with cardiopulmonary bypass. Filter A was inserted before aortic cross-clamping and left in place for a mean time of 3 minutes, and Filter B was inserted before aortic declamping for a mean of 77 minutes. An independent institution performed histopathologic examination. All filters captured particulate emboli, independent of the patients' degree of proximal aortic atherosclerotic disease. Macroscopy showed that Filter A captured more particles (mean, 70 +/- 2.6) in 7 of 15 patients (46.7%), Filter B captured more particles (mean, 6.7 +/- 2.6) in 5 of 15 patients (33.3%), and the filters captured the same number in 3 of 15 patients (20%). Microscopy showed that both filters captured fibrous atheroma or fibrous cap in 10 of 15 patients. We observed no complications related to the use of the filters. Aortic cross-clamping is associated with a high risk of embolism. We suggest that optimal protection against embolism during cardiac surgery can be achieved by applying intra-aortic filtration not only before aortic declamping but also before aortic cross-clamping.
引用
收藏
页码:515 / 521
页数:7
相关论文
共 50 条
  • [21] Predicting Fluid Responsiveness During Infrarenal Aortic Cross-Clamping in Pigs
    Biais, Matthieu
    Calderon, Joachim
    Pernot, Mathieu
    Barandon, Laurent
    Couffinhal, Thierry
    Ouattara, Alexandre
    Sztark, Francois
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) : 1101 - 1107
  • [22] CEREBROSPINAL-FLUID PRODUCTION DURING PROXIMAL AORTIC CROSS-CLAMPING
    STROMHOLM, T
    SAETHER, OD
    AADAHL, P
    UNSGARD, G
    MYHRE, HO
    [J]. EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (02): : 161 - 165
  • [23] EFFECT OF DOPAMINE ON RENAL-FUNCTION DURING AORTIC CROSS-CLAMPING
    SALEM, MG
    MCLOUGHLIN, GA
    CROOKE, JW
    MIDDLE, JG
    TAYLOR, WH
    [J]. CLINICAL SCIENCE, 1986, 71 : P45 - P46
  • [24] COMBINED CARDIAC OPERATION AND CAROTID ENDARTERECTOMY DURING AORTIC CROSS-CLAMPING
    WEISS, SJ
    SUTTER, FP
    SHANNON, TO
    GOLDMAN, SM
    [J]. ANNALS OF THORACIC SURGERY, 1992, 53 (05): : 813 - 816
  • [25] Particulate emboli capture by an intra-aortic filter device during aortic valve replacement
    Leite Filho, Osanan Amorim
    de Almeida Brandao, Carlos Manuel
    Alberto Pomerantzeff, Pablo Maria
    Vieira Guedes, Marco Antonio
    Higuchi, Maria de Lourdes
    Groppo Stolf, Noedir Antonio
    [J]. REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2008, 23 (03): : 431 - 435
  • [26] HUMAN CARDIAC MITOCHONDRIA DURING CARDIOPULMONARY BYPASS AND AORTIC CROSS-CLAMPING
    MELA, L
    ABERDEEN, E
    PARK, CD
    [J]. CIRCULATION, 1972, 46 (04) : 191 - &
  • [27] MECHANISMS OF RENAL HEMODYNAMIC IMPAIRMENT DURING INFRARENAL AORTIC CROSS-CLAMPING
    COLSON, P
    RIBSTEIN, J
    SEGUIN, JR
    MARTYANE, C
    ROQUEFEUIL, B
    [J]. ANESTHESIA AND ANALGESIA, 1992, 75 (01): : 18 - 23
  • [28] THE EFFECT OF DOPAMINE ON RENAL-FUNCTION DURING AORTIC CROSS-CLAMPING
    SALEM, MG
    MCLOUGHLIN, GA
    CROOKE, JW
    MIDDLE, JG
    TAYLOR, WH
    [J]. BRITISH JOURNAL OF SURGERY, 1987, 74 (06) : 546 - 546
  • [29] Modified technique for aortic cross-clamping during liver donor procurement
    Desai, Chirag S.
    Girlanda, Raffaele
    Hawksworth, Jason
    Fishbein, Thomas M.
    [J]. CLINICAL TRANSPLANTATION, 2014, 28 (05) : 611 - 615
  • [30] RENAL-FUNCTION DURING INFRARENAL AORTIC CROSS-CLAMPING - REPLY
    COLSON, P
    [J]. ANESTHESIA AND ANALGESIA, 1993, 76 (02): : 459 - 460