Two Everest 4000A radiometers were used to measure sea surface temperatures in the Southern Ocean from the RSV Aurora Australis during the periods 7 August 1993-9 October 1993 and 1 January 1994-1 March 1994. On four separate occasions, the radiometers were calibrated under controlled laboratory conditions using a Thermos(TM) 60-L cooler; a cool room and a Contherm(TM) unit. The calibration results were best when the radiometers and calibration target were allowed to come to equilibrium at a set temperature, with root-mean-square differences of 0.1 degrees C between the measured and actual target temperatures. When the radiometers were operated under conditions of rapid temperature change, the root-mean-square differences were found to be as large as 0.6 degrees C. The bias error of the radiometers was found to have changed subsequent to each of their deployments in the Southern Ocean, and this underlines the importance of monitoring changes in the offset of the radiometers in the field.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 50 条
  • [31] DETONIC RESEARCH INFRARED RADIOMETER WITH NANOSECOND RESPONSE
    VONHOLLE, WG
    MCWILLIAMS, RA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (09): : 1218 - 1221
  • [32] Research on calibration method of relative infrared radiometer
    Yang, Sen
    Li, Chengwei
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [33] Design of infrared spectral radiometer for diffusion flame
    Jin, Z
    Dai, JM
    Wang, LP
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2004, : 1349 - 1353
  • [34] Characterization of a thermal-infrared field radiometer
    Sicard, M
    Spyak, PR
    EARTH OBSERVING SYSTEMS II, 1997, 3117 : 269 - 280
  • [35] INFRARED RADIOMETER FOR 1969 MARINER MISSION TO MARS
    CHASE, SC
    APPLIED OPTICS, 1969, 8 (03): : 639 - &
  • [36] Spectral Calibration for the Large Aperture Infrared Radiometer
    Ye Zhao
    Wan Zhi
    Li Xian-sheng
    Ren Jian-wei
    Liu Hong-xing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (07) : 1994 - 1998
  • [37] INFRARED RADIOMETER IMPROVES WIRE AND CABLE PRODUCTION
    WHITNEY, LC
    MICROTECNIC, 1971, 25 (05): : 316 - &
  • [38] Development of an infrared high-sensitive radiometer
    Abrahamian, JA
    Adamian, ZN
    Aroutiounian, VM
    Gasparyan, FV
    Martirossian, SG
    INFRARED SPACEBORNE REMOTE SENSING VII, 1999, 3759 : 163 - 168
  • [39] LOW-NOISE RADIOMETER FOR INFRARED RANGE
    KSANFOMALITI, LV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (04): : 1178 - +
  • [40] A pyroelectric detector based nulling infrared radiometer
    Jeffries, WQ
    11TH SYMPOSIUM ON METEOROLOGICAL OBSERVATIONS AND INSTRUMENTATION, 2001, : 412 - 417