Experimental study on the air/water counter-current flow limitation in a model of the hot leg of a pressurized water reactor

被引:29
|
作者
Deendarlianto [1 ,2 ]
Vallee, Christophe [1 ]
Lucas, Dirk [1 ]
Beyer, Matthias [1 ]
Pietruske, Heiko [1 ]
Carl, Helmar [1 ]
机构
[1] Forschungszentrum Dresden Rossendorf EV, Inst Safety Res, D-01314 Dresden, Germany
[2] Gadjah Mada Univ, Fac Engn, Dept Mech & Ind Engn, Yogyakarta 55281, Indonesia
关键词
D O I
10.1016/j.nucengdes.2008.08.003
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An experimental investigation on the air/water counter-current two-phase flow in a horizontal rectangular channel connected to an inclined riser has been conducted. This test-section representing a model of the hot leg of a pressurized water reactor is mounted between two separators in a pressurized experimental vessel. The cross-section and length of the horizontal part of the test-section are (0.25 m x 0.05 m) and 2.59 m, respectively, whereas the inclination angle of the riser is 50 degrees. The flow was captured by a highspeed camera in the bended region of the hot leg, delivering a detailed view of the stratified interface as well as of dispersed structures like bubbles and droplets. Countercurrent flow limitation (CCFL), or the onset of flooding, was found by analyzing the water levels measured in the separators. The counter-current flow limitation is defined as the maximum air mass flow rate at which the discharged water mass flow rate is equal to the inlet water mass flow rate. From the high-speed observations it was found that the initiation of flooding coincides with the formation of slug flow. Furthermore, a hysteresis was noticed between flooding and deflooding. The CCFL data was compared with similar experiments and empirical correlations available in the literature. Therefore, the Wallis-parameter was calculated for the rectangular cross-sections by using the channel height as length, instead of the diameter. The agreement of the CCFL Curve is good, but the zero liquid penetration was found at lower values of the Wallis parameter than in most of the previous work. This deviation can be attributed to the special rectangular geometry of the hot leg model of FZD, since the other investigations were done for pipes. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:3389 / 3402
页数:14
相关论文
共 50 条
  • [41] Development of counter-current flow limitation model applicable to a sharp-edged liquid entrance
    Jeong, JH
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2001, 18 (06) : 824 - 830
  • [42] Development of counter-current flow limitation model applicable to a sharp-edged liquid entrance
    Ji Hwan Jeong
    [J]. Korean Journal of Chemical Engineering, 2001, 18 : 824 - 830
  • [43] Two-phase flow regimes for counter-current air-water flows in narrow rectangular channels
    Byong Joo Kim
    Byung Hu Sohn
    Siyoung Jeong
    [J]. KSME International Journal, 2001, 15 : 941 - 950
  • [44] Two-phase flow regimes for counter-current air-water flows in narrow rectangular channels
    Kim, BJ
    Sohn, BH
    Jeong, S
    [J]. KSME INTERNATIONAL JOURNAL, 2001, 15 (07): : 941 - 950
  • [45] Experimental detergent drying analysis in a counter-current spray dryer with swirling air flow
    Wawrzyniak, Pawel
    Jaskulski, Maciej
    Piatkowski, Marcin
    Sobulska, Mariia
    Zbicinski, Ireneusz
    Egan, Stefan
    [J]. DRYING TECHNOLOGY, 2020, 38 (1-2) : 108 - 116
  • [46] CFD studies on the phenomena around counter-current flow limitations of gas/liquid two-phase flow in a model of a PWR hot leg
    Deendarlianto
    Hoehne, Thomas
    Lucas, Dirk
    Vallee, Christophe
    Zabala, Gustavo Adolfo Montoya
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (12) : 5138 - 5148
  • [47] Volume of Fluid simulation of air-water co-current and Counter-current flow with variable density turbulence formulation
    Pina, Johan Sarache
    Corzo, Santiago
    Godino, Dario
    Ramajo, Damian
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2024, 424
  • [48] Numerical simulations of counter-current two-phase flow experiments in a PWR hot leg model using an interfacial area density model
    Hoehne, Thomas
    Deendarlianto
    Lucas, Dirk
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2011, 32 (05) : 1047 - 1056
  • [49] The Effect of Horizontal Pipe Length to the Onset of Flooding Position on the Air-water Counter current Two-phase Flow in a 1/30 Scale of Pressurized Water Reactor (PWR)
    Badarudin, A.
    Pinindriya, S. T.
    Yoanita, Y., V
    Hadipranoto, M. S.
    Hartono, S.
    Ariawan, R.
    Indarto
    Deendarlianto
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [50] Co-current and counter-current modes for methanol steam reforming membrane reactor: Experimental study
    Basile, A.
    Tosti, S.
    Capannelli, G.
    Vitulli, G.
    Iulianelli, A.
    Gallucci, F.
    Drioli, E.
    [J]. CATALYSIS TODAY, 2006, 118 (1-2) : 237 - 245