The comparative evaluation of patients' body dry weight under hemodialysis using two methods: Bioelectrical impedance analysis and conventional method

被引:0
|
作者
Alijanian, Neda [1 ]
Naini, Afsoon Emami [2 ]
Shahidi, Shahrzad [3 ]
Liaghat, Lida [1 ]
Samani, Rahil Riahi [1 ]
机构
[1] Isfahan Univ Med Sci, Dept Internal Med, Sch Med, Esfahan, Iran
[2] Isfahan Univ Med Sci, Isfahan Kidney Dis Res Ctr, Dept Nephrol, Sch Med, Esfahan, Iran
[3] Isfahan Univ Med Sci, Isfahan Kidney Dis Res Ctr, Dept Nephrol, Sch Med, Esfahan, Iran
来源
关键词
Bio impedance analysis; dry weight; hemodialysis; BIOIMPEDANCE SPECTROSCOPY; WHOLE-BODY; DIALYSIS PATIENTS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dry weight (DW) is an important concept related to patients undergoing hemodialysis. Conventional method seems to be time consuming and operator dependent. Bio impedance analysis (BIA) is a new and simple method reported to be an accurate way for estimating DW. In this study, we aimed to compare the conventional estimation of DW with measuring DW by BIA. Materials and Methods: This study involved 130 uremic patients, performed in Isfahan, Iran. DW was calculated by both conventional (CDW) and BIA (BIADW) method and results were compared based on different grouping factors including sex, underlying cause of renal failure (RF) (diabetic RF and non-diabetic RF), body mass index (BMI) status, and sessions of hemodialysis. We also calculated the difference between DWs of 2 methods (DW diff = CDW-BIADW). Results: The mean of BIADW was significantly lower than CDW (57.20 +/- 1.82 vs 59.36 +/- 1.77, P value < 0.001). After grouping cases according to the underlying cause, BMI, sex, and dialysis sessions BIADW was significantly lower than CDW. Conclusion: Based on the combination of problems with CDW measurement which are corrected by BIA, and more clinical reliability of CDW, we concluded that although conventional method is a time-consuming and operator-dependent way to assess DW, DW could be estimated by combining both of these methods by finding the mathematic correlation between these methods.
引用
收藏
页码:923 / 927
页数:5
相关论文
共 50 条
  • [1] Bioelectrical impedance analysis in assessment of dry weight in patients on hemodialysis
    Jerin, L
    Ladavac, R
    Zuban, F
    Pavletic-Popovic, V
    Grzalja, N
    PERIODICUM BIOLOGORUM, 2000, 102 (01) : 95 - 98
  • [2] Comparison of vector and conventional bioelectrical impedance analysis in the optimal dry weight prescription in hemodialysis
    Guida, B
    De Nicola, L
    Trio, R
    Pecoraro, P
    Iodice, C
    Memoli, B
    AMERICAN JOURNAL OF NEPHROLOGY, 2000, 20 (04) : 311 - 318
  • [3] New method of predicting dry weight using bioelectrical impedance analysis in haemodialysis patients
    Lee, Seoung Woo
    Kim, Deok Young
    Lee, Seung Hee
    Cho, Hyung Chan
    Kwon, Su Hyun
    Song, Joon Ho
    Kim, Moon Jae
    NEPHROLOGY, 2009, 14 (08) : 705 - 711
  • [4] DETERMINATION OF OPTIMAL DRY BODY WEIGHT BY BIOELECTRICAL IMPEDANCE ANALYSIS IN PATIENTS WITH END-STAGE RENAL DISEASE ON HEMODIALYSIS
    Chang, Jai Won
    Park, Tae Jin
    Park, Jong Ha
    Yang, Won Seok
    Kim, Soon Bae
    Lee, Sang Koo
    Park, Su-Kil
    Park, Jung Sik
    NEPHROLOGY, 2005, 10 : A183 - A183
  • [5] COMPARISON OF PHYSICIAN'S ASSESSMENT AND BIOELECTRICAL IMPEDANCE ANALYSIS METHODS IN DRY WEIGHT ASSESSMENT IN HEMODIALYSIS CHILDREN
    Konggrapun, Srisuwan
    NEPHROLOGY, 2014, 19 : 111 - 111
  • [6] Consistency of the Dry Weight of Hemodialysis Patients Predicted Using Bioelectrical Impedance Analysis Between Standing and Lying-Down Positions
    Kim, Hyunsuk
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 297 - 298
  • [7] RELIABLE ESTIMATION OF DRY WEIGHT IN HAEMODIALYSIS PATIENTS BY THE BIOELECTRICAL IMPEDANCE ANALYSIS
    Kim, Moon-Jae
    Lee, S. W.
    Kweon, S. H.
    Song, J. H.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 416 - 416
  • [8] Evaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis
    de Blasio, Francesca
    de Blasio, Francesco
    Berlingieri, Giulia Miracco
    Bianco, Andrea
    La Greca, Marta
    Franssen, Frits M. E.
    Scalfi, Luca
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 11 : 2419 - 2426
  • [9] Attempts to determine adequate dry weight of hemodialysis patients by a bioelectrical impedance spectroscopy device, body composition monitor-BCM (®)
    Shimobe, Tatsuhiro
    Matuo, Hiroshi
    Matsumoto, Takashi
    Nakamura, Kenji
    Minami, Takako
    Furusu, Akira
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52
  • [10] USE OF BIOELECTRICAL-IMPEDANCE ANALYSIS (BIA) FOR THE EVALUATION OF BODY-FLUID COMPOSITION IN HEMODIALYSIS AND CAPD PATIENTS
    PLUM, J
    LUBBE, M
    GRABENSEE, B
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 525 - 525