Ac-dc current transfer step-up calibration and uncertainty calculation

被引:0
|
作者
Klonz, M [1 ]
Laiz, H [1 ]
Spiegel, T [1 ]
Bittel, P [1 ]
机构
[1] PTB, D-38116 Braunschweig, Germany
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
New ac-de current transfer standards are built for the current range from 0.3 mA to 20 A and the frequency range from 10 Hz to 100 kHz. A 3-dimensional PTB-Multijunction Thermal Converter (MJTC) with a heater resistance of 27 Omega is the basic standard for the ac-dc current transfer at currents from 20 mA to 50 mA. At lower currents, planar MJTCs (PMJTCs) with heater resistances from 90 Omega to 960 Omega are used in a step-down procedure. Coaxial current shunts in parallel with PMJTCs extend the current range up to 20 A. The standard measurement uncertainties are in the range from 0.2 muA/A at 25 mA and 1 kHz to 50 muA/A at 20 A and 100 kHz. The high sensitivity of the PMJTC allows bigger steps in the step-up calibration and some smaller steps between these steps. Calibration of all these steps leads to an overdetermined system to check for the validity of the assumptions made in the step-up procedure. This results in reduced uncertainties at the different current levels compared to the old method.
引用
收藏
页码:1435 / 1440
页数:4
相关论文