Improved Local Optimization for Adaptive Bases Non-rigid Image Registration

被引:0
|
作者
Shen, Tak-Wai [1 ]
Cheung, Kwok-Wai [1 ]
机构
[1] Chu Hai Coll Higher Educ, Dept Comp Sci, Hong Kong, Hong Kong, Peoples R China
关键词
Adaptive bases algorithm; Local optimization; mutual information; non-rigid image registration;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Non-rigid image registration is an important preprocessing step in many medical image applications. It is a very computation intensive process. Adaptive bases method with local optimization is one approach used to speed up the commonly used free form deformation with B-spline transformation model. In this paper, an improved local optimization for the adaptive bases non-rigid image registration is proposed. By using smaller support size for basis function in the misregistration region identification process, the registration speed is significantly increased. The registration accuracy is also improved by using higher grid point density for local optimization in the identified misregistration region. The proposed algorithm not only preserves the advantage of computing local deformation on disjoint regions which trying to solve the problem globally, but also further reduces the running time. It can achieve notable improvement over the traditional methods. Performance of the proposed algorithm is evaluated using simulated and clinical brain dataset with standard measures such as RMSE and mutual information based similarity measure (NMI). Experimental results show that significant improvements on speed and accuracy are achieved as compared to the conventional approaches.
引用
收藏
页码:1526 / 1529
页数:4
相关论文
共 50 条
  • [21] Constrained non-rigid registration for use in image-guided adaptive radiotherapy
    Greene, W. H.
    Chelikani, S.
    Purushothaman, K.
    Knisely, J. P. S.
    Chen, Z.
    Papademetris, X.
    Staib, L. H.
    Duncan, J. S.
    MEDICAL IMAGE ANALYSIS, 2009, 13 (05) : 809 - 817
  • [22] Adaptive Non-rigid Registration and Structure from Motion from Image Trajectories
    Alessio Del Bue
    International Journal of Computer Vision, 2013, 103 : 226 - 239
  • [23] Non-rigid image registration using adaptive grid generation: Preliminary results
    Chen, Hua-mei
    Hsieh, Chih-Yao
    Liao, Guojun
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 580 - +
  • [24] Adaptive Non-rigid Registration and Structure from Motion from Image Trajectories
    Del Bue, Alessio
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2013, 103 (02) : 226 - 239
  • [25] An Improved Non-Rigid Point Set Registration Algorithm by Preserving Local Topology
    Sang, Qiang
    Huang, Tao
    Tang, Huihuang
    Jiang, Ping
    PATTERN RECOGNITION AND IMAGE ANALYSIS, 2021, 31 (04) : 646 - 655
  • [26] An Improved Non-Rigid Point Set Registration Algorithm by Preserving Local Topology
    Tao Qiang Sang
    Huihuang Huang
    Ping Tang
    Pattern Recognition and Image Analysis, 2021, 31 : 646 - 655
  • [27] Medical image non-rigid registration based on improved finite element method
    Xu, Shengzhou
    Hu, Huaifei
    Sensors and Transducers, 2013, 161 (12): : 568 - 573
  • [28] Optimal grid point selection for improved non-rigid medical image registration
    Fookes, C
    Maeder, A
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1187 - 1194
  • [29] Non-Rigid Ultrasound Image Registration Based on Intensity and Local Phase Information
    Woo, Jonghye
    Hong, Byung-Woo
    Hu, Chang-Hong
    Shung, K. Kirk
    Kuo, C. -C. Jay
    Slomka, Piotr J.
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2009, 54 (1-3): : 33 - 43
  • [30] Non-Rigid Ultrasound Image Registration Based on Intensity and Local Phase Information
    Jonghye Woo
    Byung-Woo Hong
    Chang-Hong Hu
    K. Kirk Shung
    C.-C. Jay Kuo
    Piotr J. Slomka
    Journal of Signal Processing Systems, 2009, 54 : 33 - 43