Adjusting the neurons models in neuromimetic ICs using the voltage-clamp technique

被引:6
|
作者
Saighi, Sylvain [1 ]
Buhry, Laure [1 ]
Bornat, Yannick [1 ]
N'Kaoua, Gilles [1 ]
Tomas, Jean [1 ]
Renaud, Sylvie [1 ]
机构
[1] Univ Bordeaux 1, CNRS, ENSEIRB, IMS Lab Engn Neuromoph Syst, F-33405 Talence, France
关键词
D O I
10.1109/ISCAS.2008.4541730
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an original method to tune a neuromimetic IC based on neuron conductance-based models (Hodgkin-Huxley formalism). This method is well known in electrophysiology as the "voltage-clamp" technique. It consists in measuring the neural conductances while holding the membrane voltage at a clamped level. The voltage- and time-dependent variables of the conductance equations are then interpolated from the measurements. We apply this technique on the neuromimetic IC to extract the exact parameters of the neuron model. This model is computed in software, and results are compared with the hardware simulation. We conclude by mentioning the potential applications of this technique in hardware simulation systems based on neuromimetic ASICs.
引用
收藏
页码:1564 / 1567
页数:4
相关论文
共 50 条
  • [21] VOLTAGE-CLAMP FREQUENCY-DOMAIN ANALYSIS OF NMDA-ACTIVATED NEURONS
    MOORE, LE
    HILL, RH
    GRILLNER, S
    JOURNAL OF EXPERIMENTAL BIOLOGY, 1993, 175 : 59 - 87
  • [22] A novel high throughput combined voltage-clamp/current-clamp analysis of single primary neurons
    Ghovanloo, Mohammad-Reza
    Tyagi, Sidharth
    Zhao, Peng
    Kiziltug, Emre
    Estacion, Mark
    Dib-Hajj, Sulayman
    Waxman, Stephen G.
    BIOPHYSICAL JOURNAL, 2023, 122 (03) : 101A - 101A
  • [23] High-throughput combined voltage-clamp/current-clamp analysis of freshly isolated neurons
    Ghovanloo, Mohammad -Reza
    Tyagi, Sidharth
    Zhao, Peng
    Kiziltug, Emre
    Estacion, Mark
    Dib-Hajj, Sulayman D.
    Waxman, Stephen G.
    CELL REPORTS METHODS, 2023, 3 (01):
  • [24] VOLTAGE-CLAMP ANALYSIS OF MOSSY FIBER SYNAPTIC INPUT TO HIPPOCAMPAL-NEURONS
    BROWN, TH
    JOHNSTON, D
    JOURNAL OF NEUROPHYSIOLOGY, 1983, 50 (02) : 487 - 507
  • [25] UTILIZATION OF VOLTAGE-CLAMP DATA IN GENERATION OF CHANNEL-STATE MODELS
    FELLMETH, BD
    NATION, JB
    BIOPHYSICAL JOURNAL, 1981, 33 (02) : A123 - A123
  • [26] Understanding hERG Channels Gating using Voltage-Clamp Fluorimetry
    Dou, Ying
    Es-Salah-Lamoureux, Zeineb
    Xiong, Ping Yu
    Fedida, David
    BIOPHYSICAL JOURNAL, 2012, 102 (03) : 329A - 330A
  • [27] NEW TECHNIQUE FOR SIMULTANEOUS INTERNAL DIALYSIS AND VOLTAGE-CLAMP IN MYXICOLA - ASYMMETRY CURRENTS
    SCHAUF, CL
    BULLOCK, JO
    BIOPHYSICAL JOURNAL, 1978, 21 (03) : A207 - A207
  • [28] Characterization of a Fast Voltage-Sensing Protein using Voltage-Clamp Fluorometry
    Papp, Ferenc
    Smith, Jaime
    Szilagyi, Orsolya
    Chang, Tsg-Hui
    Swartz, Kenton J.
    BIOPHYSICAL JOURNAL, 2016, 110 (03) : 103A - 103A
  • [29] ETHANOL EFFECTS ON INWARD RECTIFICATION IN LOCUS COERULEUS NEURONS UNDER VOLTAGE-CLAMP CONDITIONS
    SHEFNER, SA
    OSMANOVIC, SS
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 1988, 12 (02) : 323 - 323
  • [30] MEMBRANE CURRENTS IN SMALL CULTURED RAT HIPPOCAMPAL-NEURONS - A VOLTAGE-CLAMP STUDY
    JOHANSSON, S
    ARHEM, P
    JOURNAL OF PHYSIOLOGY-LONDON, 1992, 445 : 141 - 156