Surgical correction of high myopia in phakic eyes with Worst-Fechner myopia intraocular lenses

被引:0
|
作者
PerezSantonja, JJ [1 ]
Bueno, JL [1 ]
Zato, MA [1 ]
机构
[1] AUTONOMOUS UNIV MADRID, SCH MED, FDN JIMENEZ DIAZ, DEPT OPHTHALMOL, E-28049 MADRID, SPAIN
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND: Implanting an anterior chamber intraocular lens in a phakic eye is an effective surgical procedure for the correction of high myopia. However, the potential risks on the anterior segment structures are not well-known. We conducted a prospective study to evaluate the effectiveness, predictability, and safety after Worst-Fechner lenses were implanted to correct high myopia. METHODS: We studied 32 eyes with preoperative myopia from -9.50 to -27.00 diopters (D) (-16.60 +/- 6.29 D). All 32 eyes were studied by clinical specular microscopy, and the endothelium was analyzed for cell density. Twenty eyes mere additionally examined by fluorophotometry for lens transmittance changes. Thirty eyes were additionally examined using the flare mode of a laser flare cell photometer for anterior chamber imflammation; the patients were divided into three subgroups of ten eyes each according to when the postoperative flare measurements were done: 12 months, 18 months, and 24 months. Thirteen phakic eyes with myopia greater than -6.00 D were used as a control group for the flare study. The mean follow-up was 18.3 +/- 8 months (range 6 to 24 mo). RESULTS: Fifty-seven per cent of eyes (16 of 28) had an uncorrected visual acuity of 20/40 or better 12 months after surgery, and 58% (10 of 17 eyes) at 24 months. Spectacle-corrected visual acuity improved: 0.15 at 12 months and 0.16 at 24 months (0.1 = one line) from preoperative values. Visual acuity was stable after 3 months. Eighty per cent of eyes (25 of 31) at 6 months, 75% (21 of 28) at 12 months, and 76.5% (13 of 17) at 24 months had been correctly planned to within +1.00 D of emmetropia. The refractive results were stable 3 months after surgery. The mean endothelial cell loss was 7.2% at 3 months, 10.6% at 6 months, 13% at 12 months, and 17.6% at 24 months after surgery. The mean lens transmittance loss was 0.62% at 3 months, 0.72% at 6 months, 0.82% at 12 months, and 1.03% at 18 months after surgery. Flare values were significantly higher for eyes implanted with Worst-Fechner lenses than were those of the control group in all periods under consideration (Mann-Whitney test, p < 0.05). A decentration greater than 0.5 mm was present in 43% of eyes (14 of 32), and halos in 564 (18 of 32). In three eyes (9.3%), fixation of the lens to the iris was not stable. CONCLUSIONS: Our results for the Worst-Fechner myopia lens confirm earlier findings on the effectiveness of the refractive results. However, our study showed a continual decrease in endothelial cell density a decrease in lens transmittance, and a chronic subclinical inflammation after the implantation of these lenses. Moreover, decentration was common, and the fixation of the IOL to the iris was not stable in some eyes.
引用
收藏
页码:268 / 281
页数:14
相关论文
共 50 条
  • [21] Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia
    Barsam, Allon
    Allan, Bruce D. S.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2010, (05):
  • [22] Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia
    Barsam, Allon
    Allan, Bruce D. S.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (01):
  • [23] Phakic intraocular lenses to correct high myopia:: Adatomed, Staar, and Artisan
    Menezo, JL
    Peris-Martínez, C
    Cisneros, AL
    Martínez-Costa, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01): : 33 - 44
  • [24] Retinal detachment in phakic eyes with anterior chamber intraocular lenses to correct severe myopia
    Ruiz-Moreno, JM
    Alió, JL
    Pérez-Santonja, JJ
    de la Hoz, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (03) : 270 - 275
  • [25] Retinal detachment in phakic eyes with anterior chamber intraocular lenses to correct severe myopia
    Kwok, AKH
    Young, AL
    Bhende, P
    Lam, DSC
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (03) : 395 - 396
  • [26] THE CORRECTION OF MYOPIA BY LENS IMPLANTATION INTO PHAKIC EYES
    WILSON, SE
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (04) : 465 - 465
  • [27] Intraocular pressure in myopic patients after Worst-Fechner anterior chamber phakic intraocular lens implantation
    Aguilar-Valenzuela, L
    Lleó-Pérez, A
    Alonso-Muñoz, L
    Casanova-Izquierdo, J
    Pérez-Moltó, FJ
    Rahhal, MS
    JOURNAL OF REFRACTIVE SURGERY, 2003, 19 (02) : 131 - 136
  • [28] THE CORRECTION OF MYOPIA BY LENS IMPLANTATION INTO PHAKIC EYES
    FECHNER, PU
    VANDERHEIJDE, GL
    WORST, JGF
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (06) : 659 - 663
  • [29] Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia
    Islam M.Rizk
    Abd-Almonem A.Al-hessy
    Sherief E.El-Khouly
    Ashraf M.Sewelam
    International Journal of Ophthalmology, 2019, (02) : 284 - 290
  • [30] Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia
    Rizk, Islam M.
    Al-hessy, Abd-Almonem A.
    El-Khouly, Sheriefe
    Sewelam, Ashraf M.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (02) : 284 - 290