Innovative techniques for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart

被引:81
|
作者
Cannon, BC [1 ]
Friedman, RA [1 ]
Fenrich, AL [1 ]
Fraser, CD [1 ]
McKenzie, ED [1 ]
Kertesz, NJ [1 ]
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Div Pediat, Cardiol Sect, Houston, TX 77030 USA
来源
关键词
implantable cardioverter-defibrillator; pediatric cardiology;
D O I
10.1111/j.1540-8159.2006.00314.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Because of venous occlusion, intracardiac shunting, previous surgery, or small size placement of implantable cardioverter-defibrillator (ICD) leads may not be possible using traditional methods. The purpose of this study was to evaluate and describe innovative methods of placing ICD leads. Methods: The records of all patients undergoing ICD implantation at our institution were reviewed to identify patients with nontraditional lead placement. Indications for ICD, method of lead and coil placement, defibrillation thresholds, complications, and follow-up results were reviewed retrospectively. Results: Eight patients (aged 11 months to 29 years) were identified. Six patients with limited venous access to the heart (four extracardiac Fontan, one bidirectional Glenn, one 8 kg 11-month-old) underwent surgical placement of an ICD coil directly into the pericardial sac. A second bipolar lead was placed on the ventricle for sensing and pacing. Two patients with difficult venous access had a standard transvenous ICD lead inserted directly into the right atrium (transatrial approach) and then positioned into the ventricle. All patients had a defibrillation threshold of < 20 J, although one patient required placement of a second coil due to an elevated threshold. There have been no complications and two successful appropriate ICD discharges at follow-up (median 22 months, range 5-42 months). Conclusions: Many factors may prohibit transvenous ICD lead placement. Nontraditional surgical placement of subcutaneous ICD leads on the pericardium or the use of a transatrial approach can be effective techniques in these patients. These procedures can be performed at low risk to the patient with excellent defibrillation thresholds.
引用
收藏
页码:181 / 187
页数:7
相关论文
共 50 条
  • [21] Inappropriate shocks of implantable cardioverter-defibrillator during central venous access: A preventable complication
    Veloso, Henrique Horta
    Chaves, Jefferson Cavalcanti
    Sobrinho, Jose Jazbik
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 204 : 61 - 63
  • [22] Incidence of and predictors for appropriate implantable cardioverter-defibrillator therapy in patients with a secondary preventive implantable cardioverter-defibrillator indication
    Schaer, Beat
    Kuehne, Michael
    Reichlin, Tobias
    Osswald, Stefan
    Sticherling, Christian
    EUROPACE, 2016, 18 (02): : 227 - 231
  • [23] SILICONE POUCH FOR PROTECTION OF AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEADS
    CILLEY, JH
    CERNAIANU, AC
    LIBBY, JA
    BALDINO, WA
    DELROSSI, AJ
    ANNALS OF THORACIC SURGERY, 1991, 51 (03): : 504 - 505
  • [24] Mechanical and electrical dysfunction of Riata implantable cardioverter-defibrillator leads
    Demirel, Fatma
    Adiyaman, Ahmet
    Delnoy, Peter Paul H. M.
    Smit, Jaap Jan J.
    Misier, Anand R. Ramdat
    Elvan, Arif
    EUROPACE, 2014, 16 (12): : 1787 - 1794
  • [25] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - TECHNIQUES OF IMPLANTATION AND RESULTS
    THURER, RJ
    LUCERI, RM
    BOLOOKI, H
    ANNALS OF THORACIC SURGERY, 1986, 42 (02): : 143 - 147
  • [26] Occurrence and extraction of implantable cardioverter-defibrillator leads with conductor externalization
    Maciag, Aleksander
    Syska, Pawel
    Sterlinski, Maciej
    Kolodzinska, Agnieszka
    Oreziak, Artur
    Kusmierski, Krzysztof
    Marciniak-Emmons, Marta
    Przybylski, Andrzej
    Szumowski, Lukasz
    Opolski, Grzegorz
    Szwed, Hanna
    CARDIOLOGY JOURNAL, 2018, 25 (02) : 221 - 228
  • [27] Failure of implantable cardioverter-defibrillator leads: A matter of lead size?
    Rordorf, Roberto
    Poggio, Luca
    Savastano, Simone
    Vicentini, Alessandro
    Petracci, Barbara
    Chieffo, Enrico
    Klersy, Catherine
    Landolina, Maurizio
    HEART RHYTHM, 2013, 10 (02) : 184 - 190
  • [28] Periprocedural Risk and Survival Associated With Implantable Cardioverter-Defibrillator Placement in Older Patients With Advanced Heart Failure
    Fudim, Marat
    Ali-Ahmed, Fatima
    Parzynski, Craig S.
    Ambrosy, Andrew P.
    Friedman, Daniel J.
    Pokorney, Sean D.
    Curtis, Jeptha P.
    Fonarow, Gregg C.
    Masoudi, Frederick A.
    Hernandez, Adrian F.
    Al-Khatib, Sana M.
    JAMA CARDIOLOGY, 2020, 5 (06) : 643 - 651
  • [29] Psychological Effects of Implantable Cardioverter-Defibrillator Leads under Advisory
    Heatherly, Steven J.
    Simmons, Tony
    Fitzgerald, David M.
    Mitchell, Mark
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (06): : 694 - 699
  • [30] Prediction of atrial fibrillation in patients with an implantable cardioverter-defibrillator and heart failure
    Bertini, Matteo
    Borleffs, C. Jan Willem
    Delgado, Victoria
    Ng, Arnold C. T.
    Piers, Sebastiaan R. D.
    Shanks, Miriam
    Antoni, M. Louisa
    Biffi, Mauro
    Boriani, Giuseppe
    Schalij, Martin J.
    Bax, Jeroen J.
    Van de Veire, Nico R. L.
    EUROPEAN JOURNAL OF HEART FAILURE, 2010, 12 (10) : 1101 - 1110