An Integrated Screen-Printed Potentiometric Strip for Determination of Ca2+ in Seawater

被引:20
|
作者
Yin, Tanji [1 ,2 ,3 ]
Yu, Han [1 ,2 ,4 ,5 ]
Ding, Jiawang [1 ,2 ,3 ]
Qin, Wei [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Shandong, Peoples R China
[2] YICCAS, Shandong Prov Key Lab Coastal Environm Proc, Yantai 264003, Shandong, Peoples R China
[3] Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao 266200, Shandong, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[5] Shang Cai First Senior Middle Sch, Zhumadian 46300, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
ION-SELECTIVE ELECTRODES; CARBON NANOTUBES; CALCIUM; SURFACE; SEA;
D O I
10.1149/2.0251908jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The detection of Ca2+ in seawater is of critical importance to understand the growth of marine organisms and the circulation of the ocean ecosystem. This paper reports an integrated screen-printed potentiometric strip based on an all-solid-state Ca2+-selective polymeric membrane indicator electrode and an all-solid-state reference electrode for determination of Ca2+ in seawater, for which the conductive carbon ink-based substrate was pretreated by the physical and electrochemical methods. The proposed pretreatment procedures are found to improve the electro-transfer kinetics, decrease the electron-transfer resistances and increase the double layer capacitance of the screen-printed carbon electrode, which are favorable for constructing the all-solid-state Ca2+-ISEs without the additional materials as solid contacts. The proposed screen-printed potentiometric strip shows a stable linear potential response in the range of 1.0 x 10(-5) - 0.1 M with a slope of 26.7 +/- 1.3 mV/dec (n = 3) in the presence of 0.5 M NaCl. Additionally, the prepared potentiometric strip was used to investigate the vertical distributions of Ca2+ in seawater, and the results are consistent with those by inductively coupled plasma-optical emission spectrometry. This work indicates that the proposed potentiometric strip can be used as an alternative tool for on-site and rapid detection of Ca2+ for marine monitoring. (C) 2019 The Electrochemical Society.
引用
收藏
页码:B589 / B593
页数:5
相关论文
共 50 条
  • [1] SCREEN-PRINTED POTENTIOMETRIC STRIP FOR CALCIUM ION DETERMINATION IN WATER AND MILK
    Ping, J. F.
    Wu, J.
    Ying, Y. B.
    [J]. TRANSACTIONS OF THE ASABE, 2013, 56 (02) : 739 - 744
  • [2] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    El-Attar, Rehab O.
    Hendawy, Hassan A. M.
    Khaled, Elmorsy
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (11) : 3019 - 3029
  • [3] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    Rehab O. El-Attar
    Hassan A. M. Hendawy
    Elmorsy Khaled
    [J]. Journal of the Iranian Chemical Society, 2020, 17 : 3019 - 3029
  • [4] New potentiometric screen-printed sensors for determination of homologous sodium alkylsulfates
    Makarova, N. M.
    Kulapina, E. G.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 817 - 824
  • [5] Screen-printed reference electrodes for potentiometric measurements
    Tymecki, L
    Zwierkowska, Z
    Koncki, R
    [J]. ANALYTICA CHIMICA ACTA, 2004, 526 (01) : 3 - 11
  • [6] Novel naproxenate screen-printed potentiometric sensors
    Khaled, Elmorsy
    Shoukry, Eman M.
    Amin, Mona F.
    Said, Basmat A. M.
    Abd-Elmonem, Mahmmoud S.
    [J]. EGYPTIAN PHARMACEUTICAL JOURNAL, 2018, 17 (03) : 201 - 211
  • [7] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    El-Dessouky, Maher M. I.
    Abou El-Ella, Salwa M.
    Mohamed, Rabab T. F.
    [J]. JOURNAL OF SOLUTION CHEMISTRY, 2013, 42 (06) : 1336 - 1354
  • [8] Potentiometric Screen-Printed Bisensor for Simultaneous Determination of Chromium(III) and Chromium(VI)
    Sanchez-Moreno, Raul A.
    Jesus Gismera, Ma
    Teresa Sevilla, Ma
    Procopio, Jesus R.
    [J]. ELECTROANALYSIS, 2011, 23 (01) : 287 - 294
  • [9] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Tamer Awad Ali
    Gehad G. Mohamed
    Maher M. I. El-Dessouky
    Salwa M. Abou El-Ella
    Rabab T. F. Mohamed
    [J]. Journal of Solution Chemistry, 2013, 42 : 1336 - 1354
  • [10] Screen-Printed Potentiometric Sensors for Chloride Measurement in Soils
    Cranny, A.
    Harris, N. R.
    White, N. M.
    Barrett-Lennard, E.
    Coles, N.
    Rivers, M.
    Smettem, K.
    Wu, J.
    [J]. 26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1157 - 1160