Observer performance for JPEG vs. Wavelet image compression of x-ray coronary angiograms

被引:14
|
作者
Morioka, CA [1 ]
Eckstein, MP [1 ]
Bartroff, JL [1 ]
Hausleiter, J [1 ]
Aharanov, G [1 ]
Whiting, JS [1 ]
机构
[1] Cedars Sinai Med Ctr, Dept Med Phys & Imaging, Los Angeles, CA 90048 USA
来源
OPTICS EXPRESS | 1999年 / 5卷 / 01期
关键词
D O I
10.1364/OE.5.000008
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Development of "filmless" cardiac catheterization laboratories is eminent. The problems of implementing a digital catheterization laboratory involve archiving large amounts of data per procedure and high transfer rates to retrieve previous procedures. Lossy compression can accommodate these changes, but at the cost of possibly impairing detection of clinically important angiographic features. Our study involves the observer detection and classification of features in clinical images and the effects that JPEG and wavelet compression have on the detectability of these features. We found no significant degradation in human observer performance with 7:1 and 15:1 JPEG compressed images in 6 clinically relevant visual tasks. Human observer performance for wavelet compression degraded significantly for 2 out of 6 tasks at 7:1 compression and 4 out of 6 tasks at 19:1 compression. (C) 1999 Optical Society of America.
引用
收藏
页码:8 / 19
页数:12
相关论文
共 50 条
  • [1] Automated optimization of JPEG 2000 encoder options based on model observer performance for detecting variable signals in X-ray coronary angiograms
    Zhang, YI
    Pham, BT
    Eckstein, MP
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (04) : 459 - 474
  • [2] Evaluation of JPEG 2000 encoder options: Human and model observer detection of variable signals in X-ray coronary angiograms
    Zhang, Y
    Pham, B
    Eckstein, MP
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) : 613 - 632
  • [3] EFFECT OF LOSSY IMAGE COMPRESSION ON OBSERVER PERFORMANCE IN DYNAMICALLY DISPLAYED DIGITAL CORONARY ANGIOGRAMS
    WHITING, J
    ECKSTEIN, M
    HONIG, D
    GU, S
    EINAV, S
    EIGLER, N
    CIRCULATION, 1992, 86 (04) : 444 - 444
  • [4] Denoising and wavelet compression of X-ray image for teleradiology
    Thakur, Anita
    Bhan, Anupama
    Vyas, Garima
    2014 3RD INTERNATIONAL CONFERENCE ON RELIABILITY, INFOCOM TECHNOLOGIES AND OPTIMIZATION (ICRITO) (TRENDS AND FUTURE DIRECTIONS), 2014,
  • [5] A comparative performance analysis of JPEG 2000 vs. WSQ for fingerprint image compression
    Figueroa-Villanueva, MA
    Ratha, NK
    Bolle, RM
    AUDIO-AND VIDEO-BASED BIOMETRIC PERSON AUTHENTICATION, PROCEEDINGS, 2003, 2688 : 385 - 392
  • [6] Simulating coronary arteries in x-ray angiograms
    Morioka, CA
    Abbey, CK
    Eckstein, M
    Close, RA
    Whiting, JS
    LeFree, M
    MEDICAL PHYSICS, 2000, 27 (10) : 2438 - 2444
  • [7] Vessel Segmentation of Coronary X-ray Angiograms
    Tache, Irina Andra
    2016 20TH INTERNATIONAL CONFERENCE ON SYSTEM THEORY, CONTROL AND COMPUTING (ICSTCC), 2016, : 727 - 731
  • [8] Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks
    Eckstein, MP
    Bartroff, JL
    Abbey, CK
    Whiting, JS
    Bochud, FO
    OPTICS EXPRESS, 2003, 11 (05): : 460 - 475
  • [9] Wavelet-based compression/denoising of coronary X-ray images
    Zaid, Azza Ouled
    Bouallegue, Ammar
    Olivier, Christian
    Nait-Ali, Amine
    INTERNATIONAL JOURNAL OF SIGNAL AND IMAGING SYSTEMS ENGINEERING, 2009, 2 (1-2) : 7 - 16
  • [10] Selection of Wavelet Filters for Panoramic Dental X-Ray Image Compression
    Borwonwatanadelok, Pusit
    Purahong, Boonchana
    Udomhunsakul, Somkait
    ICECT: 2009 INTERNATIONAL CONFERENCE ON ELECTRONIC COMPUTER TECHNOLOGY, PROCEEDINGS, 2009, : 237 - +