This paper investigates the impact of possible parameter extraction errors caused by inaccurate definition of the calibration reference impedance of in-situ multiline TRL. Two calibration sets implemented on GaAs and Si/SiGe: C wafer processes were quantitatively analyzed. Obtained results demonstrated that for most practical cases, the desired 5%-level of confidence of extracted parameters of high-reflective devices can easily be achieved without additional efforts. Thus, implementation of the in-situ TRL into a characterization workflow of high-performance microwave devices can be significantly simplified.
引用
收藏
页码:593 / 596
页数:4
相关论文
共 50 条
  • [41] Review of techniques for In-Situ oxygen extraction on the moon
    Schlueter, Lukas
    Cowley, Aidan
    PLANETARY AND SPACE SCIENCE, 2020, 181
  • [42] Design of an in-situ injection/extraction bioremediation system
    Kawakami, BT
    Christ, J
    Goltz, MN
    McCarty, PL
    FIRST INTERNATIONAL CONFERENCE ON REMEDIATION OF CHLORINATED AND RECALCITRANT COMPOUNDS, VOL 6: DESIGNING AND APPLYING TREATMENT TECHNOLOGIES, 1998, : 33 - 38
  • [43] In-situ kerogen extraction via combustion and pyrolysis
    Kar, Taniya
    Hascakir, Berna
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2017, 154 : 502 - 512
  • [44] Research advances on the in-situ pressure-preserved coring and gas parameter determination for deep coal seams
    Xie H.
    Cui P.
    Shang D.
    Fan D.
    Chen L.
    Yang M.
    Du L.
    Gao M.
    Meitiandizhi Yu Kantan/Coal Geology and Exploration, 2023, 51 (08): : 1 - 12
  • [45] On the thru-reflect-line (TRL) numerical calibration and error analysis for parameter extraction of circuit model
    Li, Lin
    Wu, Ke
    Russer, Peter
    INTERNATIONAL JOURNAL OF RF AND MICROWAVE COMPUTER-AIDED ENGINEERING, 2006, 16 (05) : 470 - 482
  • [46] In-situ measurement of dielectric parameter of soil at microwave frequencies
    Mishra U.S.
    Behari J.
    Journal of the Indian Society of Remote Sensing, 2000, 28 (1) : 1 - 7
  • [47] IN-SITU VACUUM GAUGE CALIBRATION BY REFERENCE TRANSFER METHOD
    BLADO, LD
    LILIENKA.RH
    JOURNAL OF ENVIRONMENTAL SCIENCES, 1972, 15 (01): : 24 - &
  • [48] Preparation of reference glasses for in-situ analysis of lithium and boron
    Le Fevre, Brieuc
    Ottolini, Luisa
    MICROCHIMICA ACTA, 2006, 155 (1-2) : 189 - 194
  • [49] Preparation of Reference Glasses for in-situ Analysis of Lithium and Boron
    Brieuc Le Fevre
    Luisa Ottolini
    Microchimica Acta, 2006, 155 : 189 - 194
  • [50] IMPEDANCE SPECTROSCOPY AND OTHER ELECTROCHEMICAL IN-SITU INVESTIGATIONS OF THE PHOSPHATING PROCESS
    LOSCH, A
    SCHULTZE, JW
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 359 (1-2): : 39 - 61