High-Resolution Computational Fluid Dynamic Simulation of Haemodialysis Cannulation in a Patient-Specific Arteriovenous Fistula

被引:18
|
作者
Fulker, David [1 ]
Ene-Iordache, Bogdan [2 ]
Barber, Tracie [1 ]
机构
[1] Univ New South Wales, Sch Mech & Mfg Engn, Ainsworth Bldg,Kensington Campus, Kensington, NSW 2025, Australia
[2] Ist Ric Farmacol Mario Negri, IRCCS, Dept Biomed Engn, I-24020 Ranica, BG, Italy
关键词
arterial needle; venous needle; hemodialysis; access recirculation; arteriovenous fistula; turbulence; PARTICLE IMAGE VELOCIMETRY; WALL SHEAR-STRESS; VASCULAR ACCESS; VENOUS NEEDLE; DISTURBED FLOW; STENOSIS; TURBULENCE; GRAFTS; COMPLICATIONS; HEMODYNAMICS;
D O I
10.1115/1.4038289
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arteriovenous fistulae (AVF) are the preferred choice of vascular access in hemodialysis patients; however, complications such as stenosis can lead to access failure or recirculation, which reduces dialysis efficiency. This study utilized computational fluid dynamics on a patient-specific radiocephalic fistula under hemodialysis treatment to determine the dynamics of access recirculation and identify the presence of disturbed flow. Metrics of transverse wall shear stress (transWSS) and oscillatory shear index (OSI) were used to characterize the disturbed flow acting on the blood vessel wall, while a power spectral density (PSD) analysis was used to calculate the any turbulence within the access. Results showed that turbulence is generated at the anastomosis and continues through the swing segment. The arterial needle dampens the flow as blood is extracted to the dialyzer, while the venous needle reintroduces turbulence due to the presence of jet flows. Adverse shear stresses are present throughout the vascular access and coincide with these complex flow fields. The position of the needles had no effect in minimizing these forces. However, improved blood extraction may occur when the arterial needle is placed further from the anastomosis, minimizing the effects of residual turbulent structures generated at the anastomosis. Furthermore, the arterial and venous needle may be placed in close proximity to each other without increasing the risk of access recirculation, in a healthy mature fistula, due to the relatively stable blood flow in this region. This may negate the need for a long cannulation segment and aid clinicians in optimizing needle placement for hemodialysis.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A Patient-Specific Computational Fluid Dynamic Model for Hemodynamic Analysis of Left Ventricle Diastolic Dysfunctions
    Vinh-Tan Nguyen
    Wibowo, Stella Nathania
    Leow, Yue An
    Hoang-Huy Nguyen
    Liang, Zhong
    Leo, Hwa Liang
    [J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2015, 6 (04) : 412 - 429
  • [22] The importance of blood rheology in patient-specific computational fluid dynamics simulation of stenotic carotid arteries
    Jessica Benitez Mendieta
    Davide Fontanarosa
    Jiaqiu Wang
    Phani Kumari Paritala
    Tim McGahan
    Thomas Lloyd
    Zhiyong Li
    [J]. Biomechanics and Modeling in Mechanobiology, 2020, 19 : 1477 - 1490
  • [23] Patient-specific computational fluid dynamics for hypertrophic obstructive cardiomyopathy
    Hou, Quanfei
    Wu, Wenqian
    Fang, Lingyun
    Zhang, Xin
    Sun, Chenchen
    Ji, Li
    Yang, Ming
    Lei, Ziqiao
    Gao, Fan
    Wang, Jing
    Xie, Mingxing
    Chen, Shu
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 389
  • [24] The importance of blood rheology in patient-specific computational fluid dynamics simulation of stenotic carotid arteries
    Mendieta, Jessica Benitez
    Fontanarosa, Davide
    Wang, Jiaqiu
    Paritala, Phani Kumari
    McGahan, Tim
    Lloyd, Thomas
    Li, Zhiyong
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (05) : 1477 - 1490
  • [25] COMPUTATIONAL FLUID DYNAMICS - A PATIENT-SPECIFIC ASSESSMENT OF THE THORACIC AORTA
    Youssefi, Pouya
    Gomez, Alberto
    He, Taigang
    Anderson, Lisa
    Bunce, Nick
    Sharma, Rajan
    Figueroa, Alberto
    Jahangiri, Marjan
    [J]. HEART, 2016, 102 : A126 - A127
  • [26] Computational fluid dynamic evaluation of the side-to-side anastomosis for arteriovenous fistula
    Hull, Jeffrey E.
    Balakin, Boris V.
    Kellerman, Brad M.
    Wrolstad, David K.
    [J]. JOURNAL OF VASCULAR SURGERY, 2013, 58 (01) : 187 - +
  • [27] A Patient-Specific Deep-Self-Supervised High-Resolution Method for CT Imaging
    Lei, Y.
    Fu, Y.
    Wang, T.
    Curran, W.
    Liu, T.
    Yang, X.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E572 - E572
  • [28] Patient-Specific Computational Modeling of Upper Extremity Arteriovenous Fistula Creation: Its Feasibility to Support Clinical Decision-Making
    Bode, Aron S.
    Huberts, Wouter
    Bosboom, E. Marielle H.
    Kroon, Wilco
    van der Linden, Wim P. M.
    Planken, R. Nils
    van de Vosse, Frans N.
    Tordoir, Jan H. M.
    [J]. PLOS ONE, 2012, 7 (04):
  • [29] High resolution hemodynamic profiling of murine arteriovenous fistula using magnetic resonance imaging and computational fluid dynamics
    Pike, Daniel
    Shiu, Yan-Ting
    Somarathna, Maheshika
    Guo, Lingling
    Isayeva, Tatyana
    Totenhagen, John
    Lee, Timmy
    [J]. THEORETICAL BIOLOGY AND MEDICAL MODELLING, 2017, 14
  • [30] Patient-specific computational simulation of coronary artery bifurcation stenting
    Zhao, Shijia
    Wu, Wei
    Samant, Saurabhi
    Khan, Behram
    Kassab, Ghassan S.
    Watanabe, Yusuke
    Murasato, Yoshinobu
    Sharzehee, Mohammadali
    Makadia, Janaki
    Zolty, Daniel
    Panagopoulos, Anastasios
    Burzotta, Francesco
    Migliavacca, Francesco
    Johnson, Thomas W.
    Lefevre, Thierry
    Lassen, Jens Flensted
    Brilakis, Emmanouil S.
    Bhatt, Deepak L.
    Dangas, George
    Chiastra, Claudio
    Stankovic, Goran
    Louvard, Yves
    Chatzizisis, Yiannis S.
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)