High-Resolution Computational Fluid Dynamic Simulation of Haemodialysis Cannulation in a Patient-Specific Arteriovenous Fistula

被引:18
|
作者
Fulker, David [1 ]
Ene-Iordache, Bogdan [2 ]
Barber, Tracie [1 ]
机构
[1] Univ New South Wales, Sch Mech & Mfg Engn, Ainsworth Bldg,Kensington Campus, Kensington, NSW 2025, Australia
[2] Ist Ric Farmacol Mario Negri, IRCCS, Dept Biomed Engn, I-24020 Ranica, BG, Italy
关键词
arterial needle; venous needle; hemodialysis; access recirculation; arteriovenous fistula; turbulence; PARTICLE IMAGE VELOCIMETRY; WALL SHEAR-STRESS; VASCULAR ACCESS; VENOUS NEEDLE; DISTURBED FLOW; STENOSIS; TURBULENCE; GRAFTS; COMPLICATIONS; HEMODYNAMICS;
D O I
10.1115/1.4038289
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arteriovenous fistulae (AVF) are the preferred choice of vascular access in hemodialysis patients; however, complications such as stenosis can lead to access failure or recirculation, which reduces dialysis efficiency. This study utilized computational fluid dynamics on a patient-specific radiocephalic fistula under hemodialysis treatment to determine the dynamics of access recirculation and identify the presence of disturbed flow. Metrics of transverse wall shear stress (transWSS) and oscillatory shear index (OSI) were used to characterize the disturbed flow acting on the blood vessel wall, while a power spectral density (PSD) analysis was used to calculate the any turbulence within the access. Results showed that turbulence is generated at the anastomosis and continues through the swing segment. The arterial needle dampens the flow as blood is extracted to the dialyzer, while the venous needle reintroduces turbulence due to the presence of jet flows. Adverse shear stresses are present throughout the vascular access and coincide with these complex flow fields. The position of the needles had no effect in minimizing these forces. However, improved blood extraction may occur when the arterial needle is placed further from the anastomosis, minimizing the effects of residual turbulent structures generated at the anastomosis. Furthermore, the arterial and venous needle may be placed in close proximity to each other without increasing the risk of access recirculation, in a healthy mature fistula, due to the relatively stable blood flow in this region. This may negate the need for a long cannulation segment and aid clinicians in optimizing needle placement for hemodialysis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula
    Decorato, Iolanda
    Kharboutly, Zaher
    Vassallo, Tommaso
    Penrose, Justin
    Legallais, Cecile
    Salsac, Anne-Virginie
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (02) : 143 - 159
  • [2] Patient-specific computational haemodynamics associated with the surgical creation of an arteriovenous fistula
    Hyde-Linaker, George
    Barrientos, Pauline Hall
    Stoumpos, Sokratis
    Kingsmore, David Brian
    Kazakidi, Asimina
    [J]. MEDICAL ENGINEERING & PHYSICS, 2022, 105
  • [3] Patient-specific computational fluid dynamic simulation of cerebrospinal fluid flow in the intracranial space
    Fillingham, Patrick
    Levendovszky, Swati Rane
    Andre, Jalal
    Parsey, Carolyn
    Bindschadler, Michael
    Friedman, Seth
    Kurt, Mehmet
    Aliseda, Alberto
    Levitt, Michael R.
    [J]. BRAIN RESEARCH, 2022, 1790
  • [4] Patient-specific computational fluid dynamic simulation of a bilateral bidirectional Glenn connection
    Qi Sun
    Dawei Wan
    Jinfen Liu
    Haifa Hong
    Yingzheng Liu
    Ming Zhu
    [J]. Medical & Biological Engineering & Computing, 2008, 46 : 1153 - 1159
  • [5] High fidelity blood flow in a patient-specific arteriovenous fistula
    J. W. S. McCullough
    P. V. Coveney
    [J]. Scientific Reports, 11
  • [6] Patient-specific computational fluid dynamic simulation of a bilateral bidirectional Glenn connection
    Sun, Qi
    Wan, Dawei
    Liu, Jinfen
    Hong, Haifa
    Liu, Yingzheng
    Zhu, Ming
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (11) : 1153 - 1159
  • [7] High fidelity blood flow in a patient-specific arteriovenous fistula
    McCullough, J. W. S.
    Coveney, P., V
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] MANUFACTURING AND COMPUTATIONAL FLUID DYNAMICS MODELING OF A PATIENT-SPECIFIC FISTULA MODEL
    Liu, Yang
    Zheng, Yihao
    Pitre, John
    Weitzel, William
    Bull, Joseph
    Shih, Albert
    [J]. PROCEEDINGS OF THE ASME 12TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE - 2017, VOL 4, 2017,
  • [9] In-silico assessment of arteriovenous fistula maturation with patient-specific computational hemodynamic models
    Ibeas, Jose
    Martinez-Dalmau, Lidia
    Caravaca Rodriguez, Miriam
    Olivares, Andy
    Vallespin, Joaquim
    Soto, Andres
    Galles, Oscar
    Navazo, Diego
    Rubiella, Carolina
    Gonzalez de la Huebra, Teresa
    Correa Soto, Roberto
    Camara, Oscar
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I294 - I295
  • [10] Patient-Specific Simulation of Cardiac Blood Flow From High-Resolution Computed Tomography
    Lantz, Jonas
    Henriksson, Lilian
    Persson, Anders
    Karlsson, Matts
    Ebbers, Tino
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):