Wearable 3D Lung Ventilation Monitoring System with Multi Frequency Electrical Impedance Tomography

被引:0
|
作者
Kim, Minseo [1 ]
Bae, Joonsung [2 ]
Yoo, Hoi-Jun [1 ]
机构
[1] Korea Adv Inst Sci & Technol KAIST, Sch EE, Div Elect Engn, Daejeon, South Korea
[2] Kangwon Natl Univ, Dept Elect & Elect Engn, Chunchon, South Korea
关键词
Electrical impedance tomography(EIT); Multi-frequenchy eletrical impedance tomography(MFEIT); lung ventilation monitoring; real-time imaging; 3D imaging; multi-frequency EIT; maximum length sequence(MLS);
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The wearable 3D lung ventilation monitoring system is proposed with electrical impedance tomography (EIT). It is implemented on the hub-module and impedance acquisition belt. Thanks to the active electrode SoC in the impedance acquisition belt, the proposed system provides wide (94dB) and accurate (1.4m Omega) impedance acquisition. Since the optimal frequency of stimulation current varies from individual, the selecting optimal stimulation frequency scheme is proposed for multi-frequency EIT. After the measured impedance data is transferred to hub-SoC in the Hub board, it is preprocessed and transferred to an external imaging device using Bluetooth module. As a result, the proposed system can display EIT images which are reconstructed with 90% of accuracy and 10 frames/s of real-time 3D lung images. It has only 357g weight and operates at least 6 hours with 3.7V 200mAh battery.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Feature Extraction of Lung Ventilation by Biomedical Electrical Impedance Tomography
    Chen, Xiaoyan
    Chang, Xiaomin
    2017 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2017, : 558 - 562
  • [42] Electrical impedance tomography in monitoring experimental lung injury
    I. Frerichs
    G. Hahn
    T. Schröder
    G. Heilige
    Intensive Care Medicine, 1998, 24 : 829 - 836
  • [43] The Research Progress of Electrical Impedance Tomography for Lung Monitoring
    Shi, Yan
    Yang, ZhiGuo
    Xie, Fei
    Ren, Shuai
    Xu, ShaoFeng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [44] Monitoring of lung volume in dogs with electrical impedance tomography
    Adler, A
    Shinozuka, N
    Guardo, R
    Berthiaume, Y
    Bates, J
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 776 - 777
  • [45] Electrical impedance tomography in monitoring experimental lung injury
    Frerichs, I
    Hahn, G
    Schroder, T
    Hellige, G
    INTENSIVE CARE MEDICINE, 1998, 24 (08) : 829 - 836
  • [46] Frequency analysis of electrical impedance tomography system
    Szczepanik, Z
    Rucki, Z
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (04) : 844 - 851
  • [47] The Dark Side of the Lung Unveiling Regional Lung Ventilation with Electrical Impedance Tomography
    Canet, Jaume
    Gallart, Lluis
    ANESTHESIOLOGY, 2012, 116 (06) : 1186 - 1188
  • [48] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Ulrich Krause
    Kristin Becker
    Günter Hahn
    Jörg Dittmar
    Wolfgang Ruschewski
    Thomas Paul
    Pediatric Cardiology, 2014, 35 : 990 - 997
  • [49] Robust real-time inversion of electrical impedance tomography data for human lung ventilation monitoring
    Salucci, Marco
    Oliveri, Giacomo
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2019, 61 (01) : 5 - 8
  • [50] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Krause, Ulrich
    Becker, Kristin
    Hahn, Guenter
    Dittmar, Joerg
    Ruschewski, Wolfgang
    Paul, Thomas
    PEDIATRIC CARDIOLOGY, 2014, 35 (06) : 990 - 997