A Field Study of Aging in Paper-Oil Insulation Systems

被引:64
|
作者
Lelekakis, Nick [1 ]
Guo, Wenyu [1 ]
Martin, Daniel [1 ]
Wijaya, Jaury [1 ]
Susa, Dejan [2 ]
机构
[1] Monash Univ, Ctr Power Transformer Monitoring Diagnost & Life, Clayton, Vic 3800, Australia
[2] SINTEF, Energy Res Dept, N-7034 Trondheim, Norway
关键词
power transformer; paper aging; degree of polymerization; furan analysis;
D O I
10.1109/MEI.2012.6130527
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper used to insulate the windings of power transformers is mostly made from wood pulp, a cellulosic material. Over decades the paper is slowly attacked by water, oxygen, oil acids, and high temperatures and eventually degrades to the point where it is no longer an effective insulator. The transformer is then likely to fail. Power utilities need to know when a transformer is nearing the end of its useful life in order to plan its replacement. However, a problem with monitoring the condition of the paper within a transformer is that it may be difficult to obtain a sample to test. Furthermore, a particular sample may not accurately reflect the overall paper condition. A power transformer operating in Australia failed in 2010. Thus we had the opportunity to study the paper condition at various points within the transformer and evaluate the validity of the current understanding of paper aging. In this article we discuss the mechanisms of cellulose degradation, and the associated equations, and apply them to the paper insulation in the failed transformer. © 2012 IEEE.
引用
收藏
页码:12 / 19
页数:8
相关论文
共 50 条
  • [21] Assessment of moisture contents in paper-oil insulation with advanced ageing processes
    Szrot, Marek
    Subocz, Jan
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 170 - 173
  • [22] DIELECTRIC STRENGTH OF PAPER-OIL INSULATION ACTED ON BY dc VOLTAGE.
    Butkevich, V.G.
    Lokhanin, A.K.
    Ponomarenko, V.N.
    1978, 49 (04): : 47 - 52
  • [23] Using the Analysis of the Gases Dissolved in Oil in Diagnosis of Transformer Bushings with Paper-Oil Insulation-A Case Study
    Piotrowski, Tomasz
    Rozga, Pawel
    Kozak, Ryszard
    Szymanski, Zbigniew
    ENERGIES, 2020, 13 (24)
  • [24] Model building for current transformer paper-oil insulation state diagnostics
    Skrupskaya, L. S.
    Oliinyk, A. O.
    Sakhno, A. A.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2014, (02) : 48 - 51
  • [25] Structure of Paper-Oil Insulation for Mass-Impregnated HVDC Cables
    Hakonseth, G.
    Furuheim, K. M.
    Ildstad, E.
    2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 524 - 527
  • [26] Diagnostics of the paper-oil insulation condition using selected parameters of recovery voltage
    Wolny, Stefan
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 214 - 217
  • [27] Modeling of Early Stage Partial Discharge and Overheating Degradation of Paper-oil Insulation
    Tsuchie, Motoo
    Kozako, Masahiro
    Hikita, Masayuki
    Sasaki, Ei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 1342 - 1349
  • [28] The impact of aging products on modified insulation oil-paper systems
    Ding, Can
    Liu, Youzhi
    Sun, Qiankun
    Liu, Luotian
    AIP ADVANCES, 2025, 15 (02)
  • [29] Application of FEM for Understanding the Electric Field Distribution in Copper Sulphide Contaminated Paper-Oil Insulation of Power Transformer
    Rudranna, N.
    Krishnan, V.
    Rajan, J. Sundara
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 73 - +
  • [30] Near infrared spectroscopy as diagnostic method of moisture content in paper-oil insulation
    Brodka, Boleslaw
    Moscicka-Grzesiak, Hanna
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 136 - 140