Modeling of a Primary Air Distribution in a Plenum Chamber of the 700 MWth Circulating Fluidized Bed Boiler

被引:0
|
作者
Mirek, Pawel [1 ]
机构
[1] Czestochowa Tech Univ, Fac Infrastruct & Environm, Ul Dabrowskiego 73, PL-42201 Czestochowa, Poland
关键词
windbox; circulating fluidized bed boiler; fluidization; primary air; PRESSURE FLUCTUATION; FREQUENCY-ANALYSIS; WINDBOX; FLOW;
D O I
10.12913/22998624/152673
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The windbox is a compressed air chamber installed directly beneath the fluidized bed boiler grid and is designed to evenly distribute the primary air across the entire cross- section of the air distributor. Due to the large volume of the plenum chambers, it is very difficult to experimentally determine the flow conditions within them. Therefore, the analysis of airflow in these devices is usually performed using computational fluid dynamics tools. The article presents the results of modeling primary air distribution in the plenum chamber of the 700 MWth circulating fluidized bed boiler operating in PGE GiEK S.A. Turow Power Plant Division. Based on the results of calculations performed using the ANSYS Fluent software, the basic problems of the design windbox geometry were identified and a method for improving the uniformity of the gas flow under the grid was proposed. As can be seen from the results obtained, the design geometry of the windbox does not provide the required uniformity of air distribution under the grid.
引用
收藏
页码:86 / 99
页数:14
相关论文
共 50 条
  • [21] Circulating fluidized bed boiler control system
    Li, Ming
    Xu, Xiangdong
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2002, 42 (05): : 665 - 668
  • [22] Intelligent Optimization of circulating fluidized bed boiler
    Chang, Degong
    Ju, Yunpeng
    INTERNATIONAL CONFERENCE MACHINERY, ELECTRONICS AND CONTROL SIMULATION, 2014, 614 : 580 - 583
  • [23] Exergy analysis of circulating fluidized bed boiler
    Liu, Yanpeng
    Zhong, Beijing
    Li, Shaohua
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 934 - 938
  • [24] Reprint of "Experiences in sulphur capture in a 30 MWth Circulating Fluidized Bed boiler under oxy-combustion conditions"
    Gomez, M.
    Fernandez, A.
    Llavona, I.
    Kuivalainen, R.
    APPLIED THERMAL ENGINEERING, 2015, 74 : 69 - 74
  • [25] RESIDENCE TIME DISTRIBUTION OF SORBENT PARTICLES IN A CIRCULATING FLUIDIZED-BED BOILER
    LYNGFELT, A
    LECKNER, B
    POWDER TECHNOLOGY, 1992, 70 (03) : 285 - 292
  • [26] Validation and application of computational modeling to reduce erosion in a Circulating Fluidized Bed boiler
    CPFD Software, United States
    不详
    Int. J. Chem. Reactor Eng., 2012, 1
  • [27] Validation and Application of Computational Modeling to Reduce Erosion in a Circulating Fluidized Bed Boiler
    Blaser, Peter J.
    Corina, Giorgio
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2012, 10
  • [28] Modeling and prediction of key parameters of circulating fluidized bed boiler based on Transformer
    Ye, Yihua
    Lin, Haiqiang
    Zhou, Hua
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2024, 162
  • [29] Utilization of ventilation air methane as a supplementary fuel at a circulating fluidized bed combustion boiler
    You, Changfu
    Xu, Xuchang
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (07) : 2590 - 2593
  • [30] Effects of the plenum chamber volume and distributor geometry on fluidized bed hydrodynamics
    Vakhshouri, Kiarash
    Grace, John R.
    PARTICUOLOGY, 2010, 8 (01) : 2 - 12