A Glucose Biosensor Based on a 3D Nanostructured Gold Electrode

被引:11
|
作者
Tsai, Chung-Che [1 ]
Wang, Gou-Jen [1 ,2 ]
机构
[1] Natl Chung Hsing Univ, Dept Mech Engn, Taichung 40227, Taiwan
[2] Natl Chung Hsing Univ, Grad Inst Biomed Engn, Taichung 40227, Taiwan
关键词
OXIDASE; COMPOSITE;
D O I
10.1149/2.035301jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, we investigated a simple glucose biosensor based on a 3D nanostructured gold electrode. The nanostructured gold electrode was fabricated by electrochemical deposition using bulk gold dissolved in aqua regia as the nanogold precursor. Potassium ferricyanide and glucose oxidase were then sequentially coated onto the prepared nanostructure for glucose detection. For the nanostructured electrode, the polarization overpotential for glucose detection was 0.17 V, which is much smaller than that for a plane electrode. An applied potential of 0.7 V was sufficient to generate peak cathodic currents. The peak cathodic and anodic currents for the nanostructured electrode are three orders of magnitude larger than those for a plane gold electrode. The nanostructured electrode shows a fast response time of 1 s. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.035301jes] All rights reserved.
引用
收藏
页码:B1 / B5
页数:5
相关论文
共 50 条
  • [31] Disposable biosensor based on immobilization of glucose oxidase at gold nanoparticles electrodeposited on indium tin oxide electrode
    Wang, Jianwen
    Wang, Liping
    Di, Junwei
    Tu, Yifeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) : 283 - 288
  • [32] A 3D porous graphene aerogel@GOx based microfluidic biosensor for electrochemical glucose detection
    Xu, Jian
    Xu, Kangkai
    Han, Yu
    Wang, Di
    Li, Xiao
    Hu, Tao
    Yi, Hong
    Ni, Zhonghua
    ANALYST, 2020, 145 (15) : 5141 - 5147
  • [33] Fabrication of Dye-Sensitized Solar Cells with a 3D Nanostructured Electrode
    Chen, Guo-Yang
    Lee, Ming-Way
    Wang, Gou-Jen
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2010, 2010
  • [34] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the CuGeO3 nanowire modified electrode
    Yong Ping Dong
    Li Huang
    Xiang Feng Chu
    Li Zhai Pei
    Russian Journal of Electrochemistry, 2013, 49 : 571 - 576
  • [35] An Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the CuGeO3 Nanowire Modified Electrode
    Dong, Yong Ping
    Huang, Li
    Chu, Xiang Feng
    Pei, Li Zhai
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (06) : 571 - 576
  • [36] Immobilization of glucose oxidase on gold nanoparticles modified Au electrode for the construction of biosensor
    Zhang, SX
    Wang, N
    Niu, YM
    Sun, CQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 109 (02) : 367 - 374
  • [37] Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode
    Liu, SQ
    Ju, HX
    BIOSENSORS & BIOELECTRONICS, 2003, 19 (03): : 177 - 183
  • [38] A glucose biosensor based on cytochrome c and glucose oxidase co-entrapped in chitosan- gold nanoparticles modified electrode
    Song, Yonghai
    Liu, Hongyu
    Wang, Yu
    Wang, Li
    ANALYTICAL METHODS, 2013, 5 (16) : 4165 - 4171
  • [39] A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring
    Lee, Su Jin
    Yoon, Hyo Sang
    Xuan, Xing
    Park, Jae Y.
    Paik, Seung-Joon
    Allen, Mark G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 1144 - 1151
  • [40] LSPR optical fiber biosensor based on a 3D composite structure of gold nanoparticles and multilayer graphene films
    Li, Can
    Li, Zhen
    Li, Shuanglu
    Zhang, Yanan
    Sun, Baoping
    Yu, Yuehao
    Ren, Haiyang
    Jiang, Shouzhen
    Yue, Weiwei
    OPTICS EXPRESS, 2020, 28 (05): : 6071 - 6083