Study on Shielding Effectiveness of a Combined Radiation Shield for Manned Long Termed Interplanetary Expeditions

被引:7
|
作者
Al Zaman, Md. Abdullah [1 ]
Rashed, Quazi Muhammad [2 ]
机构
[1] Northern Univ Bangladesh, Dept Text Engn, Dhaka 1230, Bangladesh
[2] Univ Chittagong, Dept Phys, Chittagong 4331, Bangladesh
来源
JOURNAL OF SPACE SAFETY ENGINEERING | 2022年 / 9卷 / 01期
关键词
Space radiation; superconductivity; Polyethylene; radiation shielding; PHITS; POLYETHYLENE; PROTECTION; DEPENDENCE; SPACECRAFT;
D O I
10.1016/j.jsse.2021.12.003
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
In the course of long-duration space missions, astronauts will be exposed to galactic cosmic rays (GCR) and solar particle events (SPE). The interaction with space radiation will lead to both severe and late effects on the crew members. Two countermeasures namely active and passive shields are available but both constitute some limitations. After briefly discussing active and passive methods for radiation shielding, this paper presents a novel combined radiation shield comprising an active shield attached with a polyethylene (PE) layer of 10 cm. The effectiveness of this PE layer as combined shield has been studied theoretically by Monte Carlo calculations code, Particle and Heavy Ion Transport code System (PHITS). While the cosmic rays will travel to the spaceships, in the active part, a superconducting toroid will deflect a specific portion of the incoming particles, after that a 10cm PE layer will provide the safeguard from the secondary particles that will be produced from the interaction with the active segment. The proposed superconducting toroid under certain conditions can theoretically deflect the lighter particles (Z< 3) up to 800 MeV/n, and for higher Z particles (Z<48) this cut-off energy is around 200 MeV/n. The particles that travel through the toroid coils will pose the additional dose to the crews. The proposed PE layer can reduce the absorbed dose rate of 1.9%, 7.3%, and 27.9% for proton, alpha, and carbon ion of 1GeV/n, respectively as calculated by the PHITS. Limitations of this type of shield are also briefly discussed.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 50 条
  • [21] Effect of Li content on electromagnetic shielding effectiveness in binary Mg-Li alloys: a combined experimental and first-principles study
    Wang, Jiahao
    Du, Chunlin
    Wu, Ruizhi
    Xu, Lin
    Feng, Jing
    Zhang, Jinghuai
    Hou, Legan
    Liu, Meiduo
    Liu, Bin
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2022, 33 (07) : 3891 - 3900
  • [22] Monte Carlo simulations and Phy-X/PSD study of radiation shielding effectiveness and elastic properties of barium zinc aluminoborosilicate glasses
    Khattari, Z. Y.
    Al-Buriahi, M. S.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 195
  • [23] Efficiency of novel shielding curtains combined with pulsed irradiation for reducing radiation exposure in an operating room: Human renal collecting system phantom study
    Kaku, Yasuhiro
    Inoue, Takaaki
    Charlie, Yu
    Imai, Satoshi
    Yamamichi, Fukashi
    Fujisawa, Masato
    INTERNATIONAL JOURNAL OF UROLOGY, 2022, 29 (06) : 571 - 577
  • [24] Long-Term Effectiveness and Cost-Effectiveness of Metformin Combined with Liraglutide or Exenatide for Type 2 Diabetes Mellitus Based on the CORE Diabetes Model Study
    Zhang, Xuesong
    Liu, Sisi
    Li, Yukun
    Wang, Yan
    Tian, Meimei
    Liu, Guoqiang
    PLOS ONE, 2016, 11 (06):
  • [25] Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom
    Yoshiaki Morishima
    Koichi Chida
    Yoshikazu Muroya
    Yoshiya Utsumi
    Dysphagia, 2018, 33 : 109 - 114
  • [26] Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom
    Morishima, Yoshiaki
    Chida, Koichi
    Muroya, Yoshikazu
    Utsumi, Yoshiya
    DYSPHAGIA, 2018, 33 (01) : 109 - 114
  • [27] Does nonexistent of your hands on the screen guarantee no radiation exposure to your body?-Study on exposure of the practitioner's hands to radiation during C-arm fluoroscopy-guided injections and effectiveness of a new shielding device
    Lee, Jae-Eun
    Kim, Ju-Hyun
    Lee, Su-Jin
    Kim, Mingeon
    Nam, Tae-Woo
    Kim, Chul Hyun
    Jung, Tae-Du
    Hwang, Jong-Moon
    MEDICINE, 2019, 98 (46) : e17959
  • [28] School-based prevention for depression, anxiety, and substance use: effectiveness and long-term follow-up of the climate schools combined study
    Furneaux-Bate, Ainsley
    Newton, Nicola
    Birrell, Louise
    Slade, Tim
    Chapman, Cath
    Healy, Annalise
    Mewton, Louise
    Hides, Leanne
    McBride, Nyanda
    Allsop, Steve
    Chatterton, Mary Lou
    Teesson, Maree
    INTERNATIONAL JOURNAL OF BEHAVIORAL MEDICINE, 2021, 28 (SUPPL 1) : S2 - S3
  • [29] Long-Term Results of a Phase 2 Study of Gemcitabine and Cisplatin Chemotherapy Combined With Intensity Modulated Radiation Therapy in Locoregionally Advanced Nasopharyngeal Carcinoma
    Wu, M.
    He, X.
    Hu, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S85 - S86
  • [30] Long-term effectiveness and safety of didanosine combined with lamivudine and efavirenz or nevirapine in antiretroviral-naive patients: a 9-year cohort study in Senegal
    Laurent, Christian
    Mbougua, Jules Brice Tchatchueng
    Gueye, Ndeye Fatou Ngom
    Etard, Jean-Francois
    Diouf, Assane
    Landman, Roland
    Molinari, Nicolas
    Girard, Pierre-Marie
    Sow, Papa Salif
    Ndoye, Ibra
    Delaporte, Eric
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2011, 16 (02) : 217 - 222