A novel screen-printed electrode modified with lead film for adsorptive stripping voltammetric determination of cobalt and nickel

被引:58
|
作者
Bobrowski, Andrzej [1 ]
Krolicka, Agnieszka [1 ]
Maczuga, Mariola [1 ]
Zarebski, Jerzy [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Dept Bldg Mat Technol, PL-30059 Krakow, Poland
关键词
Adsorptive stripping voltammetry; Lead film screen printed electrode; Nickel; Cobalt; BISMUTH-FILM; ELECTROCHEMICAL CHARACTERIZATION; DIMETHYLGLYOXIME; SENSORS; NI(II); CO(II);
D O I
10.1016/j.snb.2013.10.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper presents the first report on the preparation of an in situ plated lead film screen-printed electrode (PbF-SPE) and its application for adsorptive stripping voltammetric determination of nickel and cobalt in the form of the complexes with dimethylglyoxime. The lead film was electrochemically deposited in situ on a commercially available three-electrode screen-printed electrochemical strip from a 0.2M ammonia buffer solution (pH 8.2) containing 4 x 10(-5) M Pb(NO3)(2) and 1 x 10(-5) M dimethylglyoxime. The composition of the supporting electrolyte and the influence of accumulation time on the stability of the lead coating and on the sensitivity and reproducibility of Ni and Co responses are discussed. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the lead film screen-printed electrode were equal to 4% and 3%, respectively (n = 10). The limits of detection established for simultaneous determination of Ni and Co for 90s of accumulation time were 0.2 and 0.3 mu g L-1, respectively. Voltammetric studies were complemented with optical and scanning microscopic observations. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条
  • [1] Novel Screen-printed Electrode Modified with Lead Film for Highly Sensitive and Selective Adsorptive Stripping Voltammetric Determination of Cobalt and Nickel in the Form of Dioximate Complexes
    Bobrowski, A.
    Krolicka, A.
    Maczuga, M.
    Zarebski, J.
    SENSORS AND ELECTRONIC INSTRUMENTATION ADVANCES (SEIA), 2016, : 64 - 66
  • [2] Highly Sensitive and Selective Adsorptive Stripping Voltammetric Method Employing a Lead Film Screen-printed Electrode for Determination of Cobalt as its Nioximate Complex
    Bobrowski, Andrzej
    Krolicka, Agnieszka
    Maczuga, Mariola
    Zarebski, Jerzy
    ELECTROANALYSIS, 2016, 28 (02) : 343 - 349
  • [3] The silver amalgam film electrode in catalytic adsorptive stripping voltammetric determination of cobalt and nickel
    Kapturski, Pawel
    Bobrowski, Andrzej
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 617 (01) : 1 - 6
  • [4] Adsorptive Stripping Voltammetric Determination of Amaranth and Tartrazine in Drinks and Gelatins Using a Screen-Printed Carbon Electrode
    Perdomo, Yeny
    Arancibia, Veronica
    Garcia-Beltran, Olimpo
    Nagles, Edgar
    SENSORS, 2017, 17 (11)
  • [5] Determination of Pd(II) using an antimony film coated on a screen-printed electrode by adsorptive stripping voltammetry
    Perez-Rafols, Clara
    Trechera, Pedro
    Serrano, Nuria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    TALANTA, 2017, 167 : 1 - 7
  • [6] Determination of Nifuroxazide by Flow Injection Linear Adsorptive Stripping Voltammetry on a Screen-Printed Carbon Nanofiber Modified Electrode
    Mozo, J. D.
    Carbajo, J.
    Sturm, J. C.
    Nunez-Vergara, L. J.
    Salgado, P.
    Squella, J. A.
    ELECTROANALYSIS, 2012, 24 (03) : 676 - 682
  • [7] Adsorptive stripping voltammetry of nickel and cobalt at in situ plated lead film electrode
    Korolczuk, M
    Tyszczuk, K
    Grabarczyk, M
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (12) : 1185 - 1189
  • [8] Anodic stripping voltammetric determination of aurothiomalate in urine using a screen-printed carbon electrode
    Bergamini, Marcio F.
    Boldrin Zanoni, Maria Valnice
    ELECTROANALYSIS, 2006, 18 (15) : 1457 - 1462
  • [9] Sensitive Stripping Determination of Cadmium(II) and Lead(II) on Disposable Graphene Modified Screen-Printed Electrode
    Chao Huangfu
    Fu, Liang
    Li, Yuzhi
    Li, Xueling
    Du, Haijun
    Ye, Jianshan
    ELECTROANALYSIS, 2013, 25 (09) : 2238 - 2243
  • [10] Voltammetric Determination of Diazepam on Antimony Film Screen-Printed Electrode in Pharmaceutical Formulations
    Antunovic, Vesna
    Baosic, Rada
    Lolic, Aleksandar
    CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (07) : 945 - 950