Piezo-impedance transducers for residual fatigue life assessment of bolted steel joints

被引:62
|
作者
Bhalla, Suresh [1 ]
Vittal, Panduranga A. [1 ]
Veljkovic, Milan [2 ]
机构
[1] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
[2] Lulea Univ Technol, Dept Civil Environm & Nat Resources Engn, S-95187 Lulea, Sweden
关键词
Fatigue; piezoelectric ceramic (PZT); electro-mechanical impedance (EMI) technique; residual fatigue life; DAMAGE DIAGNOSIS; ACTIVE-SENSORS; IDENTIFICATION; PERFORMANCE; BRIDGE;
D O I
10.1177/1475921712458708
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This article presents a new approach for fatigue life assessment of bolted steel joints using the equivalent stiffness determined by surface-bonded piezo-impedance transducers. The piezo transducers acquire electromechanical admittance signatures comprising the conductance (real part) and the susceptance (imaginary part), from which the equivalent system parameters of the joint are identified. The equivalent stiffness, one of the identified parameters, is experimentally found to be related to the residual stiffness of the joint and is correlated with the remaining life of the component in terms of the cycles of loading that can be further sustained by the joint. Through tests on three prototype steel joints, empirical equations are derived to relate the residual fatigue life to the loss of equivalent identified stiffness. The most promising feature of the proposed approach is that it employs the admittance signature of the surface-bonded piezo transducers directly, thereby circumventing the determination of the in situ stiffness of the joint.
引用
收藏
页码:733 / 750
页数:18
相关论文
共 50 条
  • [1] Simplified Impedance Model for Adhesively Bonded Piezo-Impedance Transducers
    Bhalla, Suresh
    Kumar, Praveen
    Gupta, Ashok
    Datta, Tushar K.
    JOURNAL OF AEROSPACE ENGINEERING, 2009, 22 (04) : 373 - 382
  • [2] Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete
    Soh, CK
    Bhalla, S
    SMART MATERIALS AND STRUCTURES, 2005, 14 (04) : 671 - 684
  • [3] Parallel and Individual Interrogations of Piezo-Impedance Transducers for Damage Detection
    Yang, Yaowen
    Liu, Hui
    Annamdas, Venu Gopal Madhav
    MATERIALS AND MANUFACTURING PROCESSES, 2010, 25 (04) : 249 - 254
  • [4] A refined shear lag model for adhesively bonded piezo-impedance transducers
    Bhalla, Suresh
    Moharana, Sumedha
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2013, 24 (01) : 33 - 48
  • [5] Structural health monitoring by piezo-impedance transducers. II: Applications
    Bhalla, S
    Soh, CK
    JOURNAL OF AEROSPACE ENGINEERING, 2004, 17 (04) : 166 - 175
  • [6] Structural health monitoring by piezo-impedance transducers. I: Modeling
    Soh, C.K. (csohck@ntu.edu.sg), 1600, American Society of Civil Engineers (17):
  • [7] Structural health monitoring by piezo-impedance transducers. I: Modeling
    Bhalla, S
    Soh, CK
    JOURNAL OF AEROSPACE ENGINEERING, 2004, 17 (04) : 154 - 165
  • [8] Characterization of the Electromechanical Admittance Signatures of Piezo-Impedance Transducers based on its Location
    Naidu, Akshay S. K.
    MATERIALS TODAY-PROCEEDINGS, 2019, 18 : 4398 - 4407
  • [9] Piezo-impedance based fatigue damage monitoring of restrengthened concrete frames
    Haq, Moinul
    Bhalla, Suresh
    Naqvi, Tabassum
    COMPOSITE STRUCTURES, 2022, 280
  • [10] Fatigue damage and residual fatigue life assessment in reinforced concrete frames using PZT-impedance transducers
    Haq, Moinul
    Bhalla, Suresh
    Naqvi, Tabassum
    CEMENT & CONCRETE COMPOSITES, 2020, 114