Characterization of the Electromechanical Admittance Signatures of Piezo-Impedance Transducers based on its Location

被引:0
|
作者
Naidu, Akshay S. K. [1 ]
机构
[1] Osmania Univ, Methodist Coll Engn & Technol, Dept Civil Engn, Hyderabad 500001, Telangana, India
关键词
Piezoelectric transducer chip; Lead-Zirconate-Titanante (PZT); Electromechanical Impedance (EMI) technique; Structural Health Monitoring (SHM); Coupled-field FE analysis; DAMAGE DETECTION;
D O I
10.1016/j.matpr.2019.07.408
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The Electromechanical Impedance method (EMI), using piezoelectric ceramics transducers such as Lead-Zirconate-Titanate (PZT), has applications in the fields of non-destructive evaluation (NDE) and structural health monitoring (SHM). The piezoceramic transducer chip (PZT) serves as an actuator supplying vibrational energy when it is bonded to the structure and subjected to harmonic voltage at ultrasonic frequency ranges. The electrical admittance of the PZT is known to be dependent on the dynamic coupling of the mechanical impedances of the PZT and the host structure. The admittance signature obtained over a frequency range serves as a diagnostic signal to monitor structural health. Any defect or damage changes the structure's mechanical impedance which gets reflected in the admittance signature. This paper examines the changes in the admittance signatures of the same PZT transducer when it is bonded at different locations of a thin plate with cantilever type end conditions. The study is purely numerical using the coupled-field FE simulations in ANSYS (TM), yet it gives better insight into admittance signature analysis, which is essential to assessing the structural health. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4398 / 4407
页数:10
相关论文
共 41 条
  • [1] Identifying damage location with admittance signatures of smart piezo-transducers
    Naidu, ASK
    Soh, CK
    [J]. JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2004, 15 (08) : 627 - 642
  • [2] Simplified Impedance Model for Adhesively Bonded Piezo-Impedance Transducers
    Bhalla, Suresh
    Kumar, Praveen
    Gupta, Ashok
    Datta, Tushar K.
    [J]. JOURNAL OF AEROSPACE ENGINEERING, 2009, 22 (04) : 373 - 382
  • [3] Damage severity and propagation characterization with admittance signatures of piezo transducers
    Naidu, ASK
    Soh, CK
    [J]. SMART MATERIALS AND STRUCTURES, 2004, 13 (02) : 393 - 403
  • [4] Parallel and Individual Interrogations of Piezo-Impedance Transducers for Damage Detection
    Yang, Yaowen
    Liu, Hui
    Annamdas, Venu Gopal Madhav
    [J]. MATERIALS AND MANUFACTURING PROCESSES, 2010, 25 (04) : 249 - 254
  • [5] A refined shear lag model for adhesively bonded piezo-impedance transducers
    Bhalla, Suresh
    Moharana, Sumedha
    [J]. JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2013, 24 (01) : 33 - 48
  • [6] Structural health monitoring by piezo-impedance transducers. II: Applications
    Bhalla, S
    Soh, CK
    [J]. JOURNAL OF AEROSPACE ENGINEERING, 2004, 17 (04) : 166 - 175
  • [7] Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete
    Soh, CK
    Bhalla, S
    [J]. SMART MATERIALS AND STRUCTURES, 2005, 14 (04) : 671 - 684
  • [8] Structural health monitoring by piezo-impedance transducers. I: Modeling
    Bhalla, S
    Soh, CK
    [J]. JOURNAL OF AEROSPACE ENGINEERING, 2004, 17 (04) : 154 - 165
  • [9] Electromechanical Admittance Signature Analysis of Piezo-ceramic Transducers for NDE
    Naidu, Akshay S. K.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2018, 5 (09) : 19933 - 19943
  • [10] Chirp-Based Piezo-Impedance Measurement
    Saar, T.
    Reidla, M.
    Martens, O.
    Land, R.
    Min, M.
    Herranen, H.
    [J]. 2013 IEEE 8TH INTERNATIONAL SYMPOSIUM ON INTELLIGENT SIGNAL PROCESSING (WISP), 2013, : 83 - 86