Polymeric ionic liquid sorbent coatings in headspace solid-phase microextraction: A green sample preparation technique for the determination of pesticides in soil

被引:32
|
作者
Orazbayeva, Dina [1 ]
Koziel, Jacek A. [2 ]
Trujillo-Rodriguez, Maria J. [3 ]
Anderson, Jared L. [3 ]
Kenessov, Bulat [1 ]
机构
[1] Al Farabi Kazakh Natl Univ, Fac Chem & Chem Technol, Ctr Phys Chem Methods Res & Anal, Alma Ata, Kazakhstan
[2] Iowa State Univ, Dept Agr & Biosyst Engn, Ames, IA 50011 USA
[3] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
基金
美国国家科学基金会;
关键词
Headspace solid-phase microextraction; Soil analysis; Current-use pesticides; Polymeric ionic liquids; CHROMATOGRAPHY-MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; ENANTIOSELECTIVE DETERMINATION; ORGANOCHLORINE PESTICIDES; METHOD VALIDATION; WATER; EXTRACTION; HERBICIDES; STABILITY; EPOXICONAZOLE;
D O I
10.1016/j.microc.2020.104996
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a green approach utilizing novel polymeric ionic liquid (PIL) coatings for headspace solid-phase microextraction (HS-SPME) of four current-use pesticides from soil samples was studied for the first time. Epoxiconazole, fluroxypyr, metribuzin, and oxyfluorfen were the target pesticides. Three PIL coatings containing 1-vinylbenzyl-3-hexadecylimidazolium bisKtrifluoromethypsulfonyllimide (PIL1 and PIL2) and 1-vinyl-3-(10-hydroxydecyl)imidazolium bis[(trifluoromethyl)sulfonyl]imide (PIL3) monomers, and 1,12-di(3-vinylbenzylimidazolium)dodecane bis[(trifluoromethyl)sulfonyl]imide (PIL1) and 1,12-di(3-vinylbenzimidazolium)dodecane bis[(trifluoromethyl)sulfonyl]imide (PIL2 and PIL3) crosslinkers were employed in this study. The performance of these PIL coatings was evaluated and compared with commercial SPME coatings based on polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polydimethylsiloxane (PDMS) at the different extraction temperatures (50-90 degrees C) and sampling times (15-60 min). HS-SPME at 90 degrees C for 60 min provided the highest sensitivity and adequate reproducibility for the majority of analytes. Despite having a lower thickness, PIL2 and PIL3 coatings provided similar extraction effectiveness of analytes, and 24-247% higher coating volume-normalized responses compared to the commercial PDMS/DVB coating. The use of the PIL1 sorbent coating resulted in excellent linearity (R-2 = 0.995-0.999) and lower detection limits (0.06-0.4 ng g(-1)) for all analytes. The optimized method provides acceptable recoveries of spiked concentrations with better performance (84-112%) achieved with the PIL1 coating. Compared to other known methods for target pesticides in soil, the proposed method provides the highest compliance with the principles of green analytical chemistry evaluated using Analytical Eco-Scale and Green Analytical Procedure Index tools.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Polymeric ionic liquid sorbent coatings in thin film microextraction: Insight into sorbent selectivity for pesticides and cannabinoids
    Zeger, Victoria R.
    Bell, David S.
    Anderson, Jared L.
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1715
  • [22] Determination of compounds with varied volatilities from aqueous samples using a polymeric ionic liquid sorbent coating by direct immersion-headspace solid-phase microextraction
    Merib, Josias
    Yu, Honglian
    Carasek, Eduardo
    Anderson, Jared L.
    ANALYTICAL METHODS, 2016, 8 (20) : 4108 - 4118
  • [23] Developing qualitative extraction profiles of coffee aromas utilizing polymeric ionic liquid sorbent coatings in headspace solid-phase microextraction gas chromatography-mass spectrometry
    Lopez-Darias, Jessica
    Anderson, Jared L.
    Pino, Veronica
    Afonso, Ana M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (09) : 2965 - 2976
  • [24] Silver-based polymeric ionic liquid sorbent coatings for solid-phase microextraction: Materials for the selective extraction of unsaturated compounds
    Trujillo-Rodriguez, Maria J.
    Anderson, Jared L.
    ANALYTICA CHIMICA ACTA, 2019, 1047 : 52 - 61
  • [25] A chemometric approach toward the detection and quantification of coffee adulteration by solid-phase microextraction using polymeric ionic liquid sorbent coatings
    Toledo, Bruna R.
    Hantao, Leandro W.
    Ho, Tien D.
    Augusto, Fabio
    Anderson, Jared L.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1346 : 1 - 7
  • [26] Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings
    Lopez-Darias, Jessica
    Pino, Veronica
    Anderson, Jared L.
    Graham, Christa M.
    Afonso, Ana M.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) : 1236 - 1243
  • [27] Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography
    Cordero-Vaca, Maria
    Trujillo-Rodriguez, Maria J.
    Zhang, Cheng
    Pino, Veronica
    Anderson, Jared L.
    Afonso, Ana M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (16) : 4615 - 4627
  • [28] Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography
    María Cordero-Vaca
    María J. Trujillo-Rodríguez
    Cheng Zhang
    Verónica Pino
    Jared L. Anderson
    Ana M. Afonso
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4615 - 4627
  • [29] Determination of organochlorine pesticides by headspace liquid phase microextraction using ionic liquid material
    Huang, Dushu
    Ping, Yi
    Long, Yunhui
    Jiang, Yan
    Pan, Qingshan
    Wu, Jie
    ADVANCED RESEARCH ON INDUSTRY, INFORMATION SYSTEM AND MATERIAL ENGINEERING, 2013, 675 : 256 - 259
  • [30] A novel headspace solid-phase microextraction method for the exact determination of organochlorine pesticides in environmental soil samples
    Rusong Zhao
    Xia Wang
    Jinpeng Yuan
    Ting Jiang
    Shan Fu
    Xiaobai Xu
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1584 - 1589