Enantioselective determination of ornidazole in human plasma by liquid chromatography-tandem mass spectrometry on a Chiral-AGP column

被引:21
|
作者
Du, Jiangbo [1 ]
Ma, Zhiyu [1 ]
Zhang, Yifan [1 ]
Wang, Ting [2 ]
Chen, Xiaoyan [1 ]
Zhong, Dafang [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Mat Med, Shanghai 201203, Peoples R China
[2] Lanzhou Univ, Affiliated Hosp 1, Lanzhou 730000, Peoples R China
关键词
Ornidazole; Enantiomers; Enantioselective liquid; chromatography-tandem mass spectrometry; Stereoselective pharmacokinetics; ANAEROBIC-BACTERIA; STEREOSELECTIVE DETERMINATION; RAT PLASMA; LC-MS/MS; ENANTIOMERS; METRONIDAZOLE; QUANTIFICATION; QUANTITATION; MECHANISM;
D O I
10.1016/j.jpba.2013.07.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, sensitive, and enantioselective method was developed and validated for determination of ornidazole enantiomers in human plasma by liquid chromatography-tandem mass spectrometry. Ornidazole enantiomers were extracted from 100 mu l of plasma using ethyl acetate. Baseline chiral separation (R-s = 2.0) was obtained within 7.5 min on a Chiral-AGP column (150 mm x 4.0 mm, 5 mu m) using an isocratic mobile phase of 10 mM ammonium acetate/acetic acid (100/0.01, v/v). Stable isotopically labeled R-(+)-d(5)-ornidazole and S-(-)-d(5)-ornidazole were synthesized as internal standards. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode via positive electrospray ionization, using the transitions of m/z 220 -> 128 for ornidazole enantiomers, and m/z 225 -> 128 for d(5)-ornidazole enantiomers. The method was linear in the concentration range of 0.030-10.0 mu g/ml for each enantiomer. The lower limit of quantification for each enantiomer was 0.030 mu g/ml. The relative standard deviation values of intra- and inter-day precision were 1.8-6.2% and 1.5-10.2% for R-(+)-ornidazole and S-(-)-ornidazole, respectively. The relative error values of accuracy ranged from -4.5% to 1.2% for R-(+)-ornidazole and from -5.4% to -0.8% for S-(-)-ornidazole. The validated method was successfully applied to a stereoselective pharmacokinetic study of ornidazole after oral administration of 1000 mg racemic ornidazole. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 50 条
  • [21] Enantioselective assay of nimodipine in human plasma using liquid chromatography-tandem mass spectrometry
    Isse, Fadumo Ahmed
    Le, Tyson
    Mahmoud, Sherif Hanafy
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (02)
  • [22] Determination of Cefotiam in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Du Ping
    Li Peng-Fei
    Liu Hong-Chuan
    Yu Wei-Yue
    Liu Li-Hong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (06) : 876 - 881
  • [23] Determination of picamilon concentration in human plasma by liquid chromatography-tandem mass spectrometry
    Cui, Wenqi
    Chen, Xiaoyan
    Zhan, Yan
    Zhang, Zhenzhong
    Zhang, Yifan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1181 - 1184
  • [24] Determination of cinacalcet hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry
    Yang, Fen
    Wang, Hongyun
    Zhao, Qian
    Liu, Hongzhong
    Hu, Pei
    Jiang, Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 237 - 241
  • [25] Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Trimetazidine in Human Plasma
    Zou, Jianjun
    Dai, Li
    Wang, Guang Ji
    Zhu, Yubing
    Fan, Hongwei
    Xiao, Da Wei
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2008, 58 (09): : 429 - 434
  • [26] Determination of tandospirone in human plasma by a liquid chromatography-tandem mass spectrometry method
    Jin, Fengdan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 2881 - 2887
  • [27] Determination of mildronate in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Lv, Yun-Feng
    Hu, Xin
    Bi, Kai-Shun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 35 - 39
  • [28] Determination of arotinoid acid in human plasma by liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Chen, Xiaoyan
    Tang, Yunbiao
    Wang, Yongqing
    Zhang, Hongwen
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 2983 - 2988
  • [29] Determination of loperamide in human plasma and saliva by liquid chromatography-tandem mass spectrometry
    Arafat, Tawfiq
    Arafat, Basil
    Awad, Riad
    Abu Awwad, Ahmad
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 972 : 81 - 88
  • [30] Determination of faropenem in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Gao, Shouhong
    Chen, Wansheng
    Tao, Xia
    Miao, Haijun
    Yang, Shaolin
    Wu, Rong
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) : 5 - 12