Numerical simulation of the insulation material transport to a PWR core under loss of coolant accident conditions

被引:6
|
作者
Hoehne, Thomas [1 ]
Grahn, Alexander [1 ]
Kliem, Soeren [1 ]
Rohde, Ulrich [1 ]
Weiss, Frank-Peter [1 ]
机构
[1] HZDR, Inst Fluid Dynam, D-01328 Dresden, Germany
关键词
WATER; FLOW;
D O I
10.1016/j.nucengdes.2013.02.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In 1992, strainers on the suction side of the ECCS pumps in Barseback NPP Unit 2 became partially clogged with mineral wool because after a safety valve opened the steam impinged on thermally insulated equipment and released mineral wool. This event pointed out that strainer clogging is an issue in the course of a loss-of-coolant accident. Modifications of the insulation material, the strainer area and mesh size were carried out in most of the German NPPs. Moreover, back flushing procedures to remove the mineral wool from the strainers and differential pressure measurements were implemented to assure the performance of emergency core cooling during the containment sump recirculation mode. Nevertheless, it cannot be completely ruled out, that a limited amount of small fractions of the insulation material is transported into the RPV. During a postulated cold leg LOCA with hot leg ECC injection, the fibers enter the upper plenum and can accumulate at the fuel element spacer grids, preferably at the uppermost grid level. This effect might affect the ECC flow into the core and could result in degradation of core cooling. It was the aim of the numerical simulations presented to study where and how many mineral wool fibers are deposited at the upper spacer grid. The 3D, time dependent, multi-phase flow problem was modeled applying the CFD code ANSYS CFX. The CFD calculation does not yet include steam production in the core and also does not include re-suspension of the insulation material during reverse flow. This will certainly further improve the coolability of the core. The spacer grids were modeled as a strainer, which completely retains all the insulation material reaching the uppermost spacer level. There, the accumulation of the insulation material gives rise to the formation of a compressible fibrous cake, the permeability of which to the coolant flow is calculated in terms of the local amount of deposited material and the local value of the superficial liquid velocity. Before the switch over of the ECC injection from the flooding mode to the sump mode, the coolant circulates in an inner convection loop in the core extending from the lower plenum to the upper plenum. The CFD simulations have shown that after starting the sump mode, the ECC water injected through the hot legs flows down into the core at the so-called breakthrough channels located at the outer core region where the downward leg of the convection roll had established. The hotter, lighter coolant rises in the center of the core. As a consequence, the insulation material is preferably deposited at the uppermost spacer grids positioned in the breakthrough zones. This means that the fibers are not uniformly deposited over the core cross section. When the inner recirculation stops later in the transient, insulation material can also be collected in other regions of the core. Nevertheless, with a total of 2.7 kg fiber material deposited at the uppermost spacer level, the pressure drop over the fiber cake is not higher than 8 kPa and all the ECC water could still enter the core. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 50 条
  • [41] QUALIFICATION OF ELECTRICAL COMPONENTS FOR LOSS-OF-COOLANT ACCIDENT CONDITIONS
    STEINER, SE
    KERNTECHNIK, 1989, 54 (02) : 126 - 130
  • [42] ANALYSIS OF A SIMULATED SMALL BREAK IN THE SEMISCALE SYSTEM UNDER LOSS-OF-COOLANT ACCIDENT CONDITIONS
    CARTMILL, CE
    NUCLEAR TECHNOLOGY, 1979, 46 (03) : 422 - 427
  • [43] Numerical Simulation of Interior Flow Field of Reactor Coolant Pump under Station Blackout Accident
    Xu Yi-Ming
    Xu Shi-Ming
    FUTURE MATERIAL RESEARCH AND INDUSTRY APPLICATION, PTS 1 AND 2, 2012, 455-456 : 1002 - 1008
  • [45] Simulation of nuclear fuel clad high-temperature ballooning under loss-of-coolant accident conditions considering anisotropic creep
    Li, Wei
    Chen, Hongxi
    Wu, Xiaoli
    Duan, Qianni
    Su, G. H.
    ANNALS OF NUCLEAR ENERGY, 2024, 203
  • [46] Three dimensional Monte-Carlo simulation method for LMFBR fuel bundle heat transfer under loss of coolant accident conditions
    Bottoni, Maurizio
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2007, 41 (02): : 203 - 210
  • [47] Loss of coolant accident analysis under restriction of reverse flow
    Radaideh, Majdi, I
    Kozlowski, Tomasz
    Farawila, Yousef M.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (06) : 1532 - 1539
  • [48] Failure assessment of RPV nozzle under loss of coolant accident
    Siegele, D
    Hodulak, L
    Varfolomeyev, I
    Nagel, G
    NUCLEAR ENGINEERING AND DESIGN, 1999, 193 (03) : 265 - 272
  • [49] Numerical simulation on coolant flow and heat transfer in core
    Yao, Zhaohui
    Wang, Xuefang
    Shen, Mengyu
    Hedongli Gongcheng/Nuclear Power Engineering, 1997, 18 (04): : 332 - 339
  • [50] Numerical simulation of core temperature and melting process of IVR core after a severe water loss accident
    Liu, Yiqun
    Zhang, Xiaoying
    Li, Jingya
    Wang, Biao
    Zhan, Dekui
    Zhang, Huiyong
    Xu, Junying
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 6, 2017,