Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography

被引:75
|
作者
Wang, Tianshi [1 ]
Pfeiffer, Tom [2 ,3 ]
Regar, Evelyn [1 ]
Wieser, Wolfgang [2 ]
van Beusekom, Heleen [1 ]
Lancee, Charles T. [1 ]
Springeling, Geert [1 ]
Krabbendam, Ilona [1 ]
van der Steen, Antonius F. W. [1 ,4 ,5 ]
Huber, Robert [2 ,3 ]
van Soest, Gijs [1 ]
机构
[1] Erasmus Univ, Med Ctr, Thorax Ctr, NL-3000 CA Rotterdam, Netherlands
[2] Univ Munich, Fak Phys, Lehrstuhl Biomol Opt, D-80538 Munich, Germany
[3] Med Univ Lubeck, Inst Biomed Opt, D-23562 Lubeck, Germany
[4] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[5] Delft Univ Technol, Dept Imaging Sci & Technol, NL-2600 AA Delft, Netherlands
来源
BIOMEDICAL OPTICS EXPRESS | 2015年 / 6卷 / 12期
基金
欧洲研究理事会;
关键词
PERCUTANEOUS CORONARY INTERVENTION; DOMAIN MODE-LOCKING; ROTATIONAL DISTORTION; IMAGING CATHETER; MOTION ARTIFACTS; ANGIOGRAPHY; REGISTRATION; ULTRASOUND; SEQUENCES; SCAFFOLD;
D O I
10.1364/BOE.6.005021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cardiac motion artifacts, non-uniform rotational distortion and undersampling affect the image quality and the diagnostic impact of intravascular optical coherence tomography (IV-OCT). In this study we demonstrate how these limitations of IV-OCT can be addressed by using an imaging system that we called "Heartbeat OCT", combining a fast Fourier Domain Mode Locked laser, fast pullback, and a micromotor actuated catheter, designed to examine a coronary vessel in less than one cardiac cycle. We acquired in vivo data sets of two coronary arteries in a porcine heart with both Heartbeat OCT, working at 2.88 MHz A-line rate, 4000 frames/s and 100 mm/s pullback speed, and with a commercial system. The in vivo results show that Heartbeat OCT provides faithfully rendered, motion-artifact free, fully sampled vessel wall architecture, unlike the conventional IV-OCT data. We present the Heartbeat OCT system in full technical detail and discuss the steps needed for clinical translation of the technology. (C) 2015 Optical Society of America
引用
收藏
页码:5021 / 5032
页数:12
相关论文
共 50 条
  • [32] Debate: Intravascular ultrasound and optical coherence tomography in percutaneous revascularization. The OCT expert perspective
    Gonzalo, Nieves
    REC-INTERVENTIONAL CARDIOLOGY, 2020, 2 (04): : 291 - 293
  • [33] Heartbeat optical coherence elastography: corneal biomechanics in vivo
    Nair, Achuth
    Singh, Manmohan
    Aglyamov, Salavat
    Larin, Kirill, V
    JOURNAL OF BIOMEDICAL OPTICS, 2021, 26 (02)
  • [34] 4D megahertz optical coherence tomography (OCT): imaging and live display beyond 1 gigavoxel/sec
    Huber, Robert A.
    Draxinger, Wolfgang
    Wieser, Wolfgang
    Kolb, Jan Philip
    Pfeiffer, Tom
    Karpf, Sebastian N.
    Eibl, Matthias
    Klein, Thomas
    HIGH-SPEED BIOMEDICAL IMAGING AND SPECTROSCOPY: TOWARD BIG DATA INSTRUMENTATION AND MANAGEMENT, 2016, 9720
  • [35] Atlas of Retinal OCT: Optical Coherence Tomography
    Serebrianik, Roman
    OPTOMETRY AND VISION SCIENCE, 2024, 101 (05) : 251 - 251
  • [36] Optical Coherence Tomography (OCT) in Glaucoma Diagnostics
    Hoffmann, E. M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (02) : 135 - 142
  • [37] Tissue characterization, with optical coherence tomography (OCT)
    Knuttel, A
    Koch, S
    Schork, R
    Bocker, D
    BIOMEDICAL SENSING, IMAGING, AND TRACKING TECHNOLOGIES I, 1996, 2676 : 54 - 64
  • [38] Corneal laceration on optical coherence tomography (OCT)
    Guyot, C.
    Fossum, P.
    Orignac, I.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (04): : E155 - E156
  • [39] Tissue characterization with optical coherence tomography (OCT)
    Knuttel, A
    Breit, M
    Bocker, D
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS, PROCEEDINGS OF, 1997, 2981 : 7 - 18
  • [40] Optical coherence tomography (OCT) in macular edema
    Rosario Brancato
    Documenta Ophthalmologica, 1999, 97 : 337 - 339