Establishment of One-axis Vibration Test System for Measurement of Biodynamic Response of Human Hand-arm System

被引:7
|
作者
Shibata, Nobuyuki [1 ]
Hosoya, Naoki [2 ]
Maeda, Setsuo [1 ]
机构
[1] NIOSH, Dept Res Planning & Coordinat, Tama Ku, Kawasaki, Kanagawa 2148585, Japan
[2] Shibaura Inst Technol, Dept Mech Engn 2, Tokyo 1358548, Japan
关键词
Single-axis vibration; Hand-arm vibration; Dynamic response; Apparent mass; ISO10068;
D O I
10.2486/indhealth.46.629
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Prolonged exposure to hand-arm vibration (HAV) due to use of hand-held power tools leads to an increased occurrence of symptoms of disorders in the vascular, neurological, and osteo-articular systems of the upper limbs called hand-arm vibration syndrome (HAVS). Biodynamic responses of the hand-arm system to vibration can be suggestive parameters that give us better assessment of exposure to HAV and fundamental data for design of low-vibration-exposure power tools. Recently, a single axis hand-arm vibration system has been installed in the Japan National Institute of Occupational Safety and Health (NIOSH). The aims of this study were to obtain the fundamental dynamic characteristics of an instrumented handle and to validate the performance and measurement accuracy of the system applied to dynamic response measurement. A pseudo-random vibration signal with a frequency range of 5-1,250 Hz and a power spectrum density of 1.0 (m/s(2))(2)/Hz was used in this study. First the dynamic response of the instrumented handle without any weight was measured. After this measurement, the dynamic response measurement of the handle with weights mounted on the handle was performed. The apparent mass of a weight itself was obtained by using the mass cancellation method. The mass of the measuring cap on the instrumented handle was well compensated by using the mass cancellation method. Based on the 10% error tolerance, this handle can reliably measure the dynamic response represented by an apparent mass with a minimum weight of 2.0 g in a frequency range of 10.0 to 1,000 Hz. A marked increase in the AM magnitude of the weights of 15 g and 20 g in frequency ranges greater than 800 Hz is attributed not to the fundamental resonance frequency of the handle with weights, but to the fixation of the weight to the measuring cap. In this aspect, the peak of the AM magnitude can be reduced and hence should not be an obstacle to the biodynamic response measurement of the human hand-arm system. On the basis of the results obtained in this study, we conclude that this hand-arm vibration test system can be used to measure biodynamic response parameters of the human hand-arm system.
引用
收藏
页码:629 / 634
页数:6
相关论文
共 50 条
  • [41] Characteristics of vibration transmission in the hand-arm system and subjective response during field operation of a hand tractor
    Dewanyan, K. N.
    Tewari, V. K.
    BIOSYSTEMS ENGINEERING, 2008, 100 (04) : 535 - 546
  • [42] Recent advances in biodynamics of human hand-arm system
    Dong, RG
    Wu, JZ
    Welcome, DE
    INDUSTRIAL HEALTH, 2005, 43 (03) : 449 - 471
  • [43] FURTHER CONTRIBUTIONS TO THE MODELING OF THE HUMAN HAND-ARM SYSTEM
    Gligor, Claudiu Alin
    Arghir, Mariana
    ACTA TECHNICA NAPOCENSIS SERIES-APPLIED MATHEMATICS MECHANICS AND ENGINEERING, 2014, 57 (03): : 429 - 434
  • [44] A study of the modal behavior of the human hand-arm system
    Thomas, C
    Rakheja, S
    Bhat, RB
    Stiharu, I
    JOURNAL OF SOUND AND VIBRATION, 1996, 191 (01) : 171 - 176
  • [45] Nonlinear Biodynamic Models of the Hand-arm System and Parameters Identification using the Vibration Transmissibility or the Driving-point Mechanical Impedance
    Hida, Nahid
    Abid, Mohamed
    Lakrad, Faouzi
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2021, 7 (02): : 944 - 955
  • [46] An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions
    Welcome, Daniel E.
    Dong, Ren G.
    Xu, Xueyan S.
    Warren, Christopher
    McDowell, Thomas W.
    Wu, John Z.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2015, 45 : 21 - 34
  • [47] DYNAMIC-RESPONSE OF HAND-ARM SYSTEM TO A SINUSOIDAL INPUT
    REYNOLDS, DD
    SOEDEL, W
    JOURNAL OF SOUND AND VIBRATION, 1972, 21 (03) : 339 - &
  • [48] Vibration transmissibility characteristics of the human hand-arm system under different postures, hand forces and excitation levels
    Adewusi, S. A.
    Rakheja, S.
    Marcotte, P.
    Boutin, J.
    JOURNAL OF SOUND AND VIBRATION, 2010, 329 (14) : 2953 - 2971
  • [49] Biomechanical models of the hand-arm system to predict the hand gripping forces and transmitted vibration
    Wang, Zunming
    Qiu, Yi
    Zheng, Xu
    Hao, Zhiyong
    Liu, Chi
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2022, 88
  • [50] Biomechanical models of the hand-arm system to predict the hand gripping forces and transmitted vibration
    Wang, Zunming
    Qiu, Yi
    Zheng, Xu
    Hao, Zhiyong
    Liu, Chi
    International Journal of Industrial Ergonomics, 2022, 88