Feasibility and reference values of left atrial longitudinal strain imaging by two-dimensional speckle tracking

被引:296
|
作者
Cameli, Matteo [2 ]
Caputo, Maria [2 ]
Mondillo, Sergio [2 ]
Ballo, Piercarlo [1 ]
Palmerini, Elisabetta [2 ]
Lisi, Matteo [2 ]
Marino, Enzo [3 ]
Galderisi, Maurizio [4 ]
机构
[1] S Andrea Hosp, Cardiol Operat Unit, La Spezia, Italy
[2] Univ Siena, Dept Cardiovasc Dis, I-53100 Siena, Italy
[3] GE Healthcare, Milan, Italy
[4] Federico II Univ Hosp, Cardioangiol Unit, CCU, Dept Clin & Expt Med, Naples, Italy
关键词
ECHOCARDIOGRAPHIC EVALUATION; DEFORMATION; QUANTIFICATION;
D O I
10.1186/1476-7120-7-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of speckle tracking in the assessment of left atrial (LA) deformation dynamics is not established. We sought to determine the feasibility and reference ranges of LA longitudinal strain indices measured by speckle tracking in a population of normal subjects. Methods: In 60 healthy individuals, peak atrial longitudinal strain (PALS) and time to peak longitudinal strain (TPLS) were measured using a 12-segment model for the left atrium. Values were obtained by averaging all segments (global PALS and TPLS) and by separately averaging segments measured in the two apical views (4- and 2-chamber average PALS and TPLS). Results: Adequate tracking quality was achieved in 97% of segments analyzed. Results: Adequate tracking quality was achieved in 97% of segments analyzed. Inter and intraobserver variability coefficients of measurements ranged between 2.9% and 5.4%. Global PALS was 42.2 +/- 6.1% (5-95 degrees percentile range 32.2-53.2%), and global TPLS was 368 +/- 30 ms (5-95 degrees percentile range 323-430 ms). The 2-chamber average PALS was slightly higher than the 4-chamber average PALS (44.3 +/- 6.0% vs 40.1 +/- 7.9%, p < 0.0001), whereas no differences in TPLS were found (p = 0.93). Conclusion: Speckle tracking is a feasible technique for the assessment of longitudinal myocardial LA deformation. Reference ranges of strain indices were reported.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Experimental validation of left ventricular transmural strain gradient with echocardiographic two-dimensional speckle tracking imaging
    Ishizu, Tomoko
    Seo, Yoshihiro
    Enomoto, Yoshiharu
    Sugimori, Haruhiko
    Yamamoto, Masayoshi
    Machino, Tomoko
    Kawamura, Ryo
    Aonuma, Kazutaka
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (04): : 377 - 385
  • [22] Regional nonuniformity of left ventricular strain, rotation, and twist assessed by two-dimensional speckle tracking imaging
    Takeuchi, Masaaki
    Nakai, Hirom
    Nishikage, Tomoko
    Nagakura, Toshiki
    Otani, Shinichiro
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 108A - 108A
  • [23] Interobserver Agreement of Left Atrial Strain Assessment by Two-Dimensional Speckle Echocardiography
    Haji, Kawa
    Huynh, Quan
    Be, Kim Kuy
    Wright, Leah
    Marwick, Thomas H.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2022, 35 (02) : 228 - 229
  • [24] Reduced longitudinal and radial strain of the left ventricle in patients with hypertrophic cardiomyopathy (HCM): a study using two-dimensional speckle tracking imaging
    Abozguia, K.
    Shivu, G. Nallur
    Ahmed, I.
    Phan, T. T.
    Maher, A. R.
    Mckenna, W. J.
    Elliott, P. M.
    Frenneaux, M. P.
    EUROPEAN HEART JOURNAL, 2008, 29 : 55 - 55
  • [25] Second Trimester Ultrasound: Reference Values for Two-Dimensional Speckle Tracking-Derived Longitudinal Strain, Strain Rate and Time to Peak Deformation of the Fetal Heart
    Kapusta, Livia
    Mainzer, Gur
    Weiner, Zeev
    Deutsch, Lisa
    Khoury, Asaad
    Haddad, Sami
    Lorber, Avraham
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (12) : 1333 - 1341
  • [26] Deterioration in Left Atrial Strain After Repeated Pulmonary Vein Isolation for Atrial Fibrillation - A Two-Dimensional Speckle Tracking Study
    To, Andrew C.
    Singh, Dhssraj
    Agler, Deborah
    Bhargava, Mandeep
    Saliba, Walid I.
    Klein, Allan L.
    CIRCULATION, 2010, 122 (21)
  • [27] Assessment of left atrial mechanical function and synchrony in paroxysmal atrial fibrillation with two-dimensional speckle tracking echocardiography-utility of left atrial speckle tracking without left ventricular speckle tracking? Reply
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (07): : 1113 - 1113
  • [28] Automated left atrial volume measurement by two-dimensional speckle-tracking echocardiograpy. Feasibility, accuracy, and reproducibility
    Florescu, Diana Ruxandra
    Badano, Luigi Paolo
    Tomaselli, Michele
    Torlasco, Camilla
    Tartea, Georgica
    Florescu, Cristina
    Volpato, Valentina
    Parati, Gianfranco
    Muraru, Denisa
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (SUPPL G)
  • [29] Automated left atrial volume measurement by two-dimensional speckle-tracking echocardiograpy. Feasibility, accuracy, and reproducibility
    Florescu, Diana Ruxandra
    Badano, Luigi Paolo
    Tomaselli, Michele
    Torlasco, Camilla
    Tartea, Georgica
    Florescu, Cristina
    Volpato, Valentina
    Parati, Gianfranco
    Muraru, Denisa
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0G) : G41 - +
  • [30] TWO-DIMENSIONAL SPECKLE STRAIN IMAGING IDENTIFIES DEPRESSED LEFT ATRIAL FUNCTION IN HYPERTENSIVE PATIENTS WITH DIASTOLIC DYSFUNCTION
    Khan, Umar A.
    Chinali, Marcello
    Aurigemma, Gerard P.
    Hill, Jeffrey C.
    De Simone, Giovanni
    Tighe, Dennis A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)