Investigation of the effect of impact load on concrete-filled steel tube columns under fire

被引:0
|
作者
Pahlaviani, Ali Golsoorat [1 ]
Rousta, Ali Mohammad [2 ]
Beiranvand, Peyman [3 ]
机构
[1] Islamic Azad Univ, Cent Tehran Branch, Tehran, Iran
[2] Univ Yasuj, Dept Civil Engn, Yasuj, Iran
[3] Razi Univ, Dept Civil Engn, Kermanshah, Iran
来源
FRATTURA ED INTEGRITA STRUTTURALE | 2020年 / 14卷 / 54期
关键词
Concrete-Filled Steel Tube; Impact load; Confinement factor; BEHAVIOR;
D O I
10.3221/IGF-ESIS.54.22
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Concrete-filled steel tube (CFST) columns are increasingly used in the construction of high-rise buildings which require high strength and large working space especially at lower stories. As compared to reinforced concrete columns, existence of the exterior steel tube not only bears a portion of axial load but also most importantly provides confinement to the infill concrete.with the confinement provided by the steel tube, axial strength of the infill concrete can be largely enhanced.this paper presents the investigation effect of impact load on concrete-filled steel tube columns under fire by numerical simulations using ABAQUS software.the results indicate that the CFST sections with larger confinement factor xi=1.23 behaved in a very ductile manner under lateral impact. And the sections with smaller confinement factor xi=0.44 generally behaved in a brittle mechanism.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [21] ISO Standard Fire Tests of Concrete-Filled Steel Tube Columns with Solid Steel Core
    Neuenschwander, Martin
    Knobloch, Markus
    Fontana, Mario
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (04)
  • [22] Nonlinear finite element analysis of square concrete-filled steel tube columns under compressive load
    Department of Engineering Mechanics, Shanghai Jiaotong University, Shanghai 200240, China
    Gongcheng Lixue, 2007, 3 (110-114):
  • [23] Behavior of concrete-filled steel tube beam columns
    Inai, E
    Mukai, A
    Kai, M
    Tokinoya, H
    Fukumoto, T
    Mori, K
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2004, 130 (02): : 189 - 202
  • [24] Experimental and numerical investigation of concrete-filled stainless steel columns exposed to fire
    Tao, Zhong
    Ghannam, Mohamed
    Song, Tian-Yi
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 118 : 120 - 134
  • [25] Post-earthquake fire performance of square concrete-filled steel tube columns
    Wang, Yu-Hang
    Tang, Qi
    Su, Mei-Ni
    Tan, Ji-Ke
    Wang, Wei-Yong
    Lan, Yong-Sen
    Luo, Wei
    Zhou, Yang
    THIN-WALLED STRUCTURES, 2020, 154
  • [26] POST-FIRE PERFORMANCE OF ELLIPTICAL CONCRETE-FILLED STEEL TUBE STUB COLUMNS
    Song, T. Y.
    Zhang, J. C.
    Xiang, K.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1459 - 1469
  • [27] Material effect for predicting the fire resistance of concrete-filled square steel tube column under constant axial load
    Chung, Kyungsoo
    Park, Suhee
    Choi, Sungmo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (12) : 1505 - 1515
  • [28] Experimental and numerical investigation on post-earthquake fire behaviour of the circular concrete-filled steel tube columns
    Wang, Hang
    Tang, Qi
    Su, Mei-Ni
    Tan, Ji-Ke
    Wang, Wei-Yong
    Lan, Yong-Sen
    Deng, Xiao-Wei
    Bai, Yong-Tao
    Luo, Wei
    Li, Xiao-Hua
    Bai, Jiu-Lin
    STEEL AND COMPOSITE STRUCTURES, 2021, 38 (01): : 17 - 31
  • [29] Behavior of multicell concrete-filled steel tube columns under eccentric loading
    Yin, Fei
    Cao, Wan-Lin
    Xue, Su-Duo
    Dong, Hong-Ying
    Wang, Ru-wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172 (172)
  • [30] Fire resistance of concrete-filled steel tube columns with preload. Part II: Numerical and analytical investigation
    Yu, Min
    Wang, Tan
    Huang, Weijun
    Ye, Jianqiao
    COMPOSITE STRUCTURES, 2019, 223